Product Name:FLEX I/O Digital Input Modules
Brand Name: Allen Bradley
Model Number:1794-IB8
Country of Origin:USA
Warranty: 12 Months
Whatsapp:+86 18159889985
Email:[email protected]
Brand Name: |
Allen Bradley |
Model Number: |
1794-IB8 |
Country of Origin: |
USA |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
Delivery time in stock |
Payment Terms: |
T/T |
|
Sales Manager: |
Stella |
|
Send an email: |
|
|
Contact in Whatsapp: |
|
Parameter |
Specification |
|
Catalog Number |
1794-IB8 |
|
Manufacturer |
Rockwell Automation / Allen-Bradley |
|
Product Family |
FLEX I/O |
|
Number of Inputs |
8 (current-sinking) |
|
Onstate Voltage (min.) |
10V DC |
|
Onstate Voltage (nom.) |
24V DC |
|
Onstate Voltage (max.) |
31.2V DC |
|
Onstate Current (min.) |
2.0 mA |
|
Onstate Current (nom.) |
8.0 mA |
|
Onstate Current (max.) |
12.0 mA |
|
Offstate Voltage (max.) |
5.0V DC |
|
Offstate Current (max.) |
1.5 mA |
|
Nominal Input Impedance |
4.6 kΩ |
|
Isolation Voltage |
50V continuous (Basic Insulation Type); type tested @ 850V DC for 60 s between field side and system; no isolation between individual channels |
|
Flexbus Current |
20 mA @ 5V DC |
|
Power Dissipation (max.) |
3.5 W @ 31.2V DC |
|
Thermal Dissipation (max.) |
11.9 BTU/hr @ 31.2V DC |
|
Surrounding Air Temperature Range |
–20°C to +55°C (–4°F to +131°F) |
|
Storage Temperature |
–40°C to +85°C |
|
Relative Humidity |
5 to 95% non-condensing |
|
Altitude |
Up to 2000 m (6562 ft) without derating |
|
Agency Certifications |
c-UL-us (Class I Division 2 Groups A-D), UK/CE, ATEX (Ex ec IIC T3 Gc), IECEx (Ex ec IIC T3 Gc), RCM, KC |
|
Terminal Base Compatibility |
1794-TB3, 1794-TB3S |
|
Dimensions |
9.4x5x5.5cm |
|
Weight |
0.08kg |
The 1794-IB8 is an 8‑channel DC sinking input module from Rockwell Automation‘s FLEX I/O family, engineered to interface discrete field devices with programmable automation controllers. The 1794-IB8 accepts 24V DC signals from sourcing sensors such as pushbuttons, limit switches, and proximity sensors, converting them to logic‑level data for the controller. The 1794-IB8 mounts on a terminal base (1794‑TB3 or 1794‑TB3S) and connects to the backplane via the Flexbus connector. With a nominal input current of 8 mA, adjustable filter times up to 32 ms, and hazardous location approvals (Class I Division 2, ATEX Zone 2), the 1794-IB8 delivers reliable performance in demanding industrial environments.
Discrete Manufacturing – Monitoring pushbuttons, selector switches, and limit switches on packaging lines, conveyors, and assembly machinery
Material Handling Systems – Sensing product presence, position feedback, and jam detection via photoelectric sensors and proximity switches in automated warehouses
Process Control – Monitoring tank level switches, valve position feedback, and pump status in batch processing and continuous flow applications
Safety Interlock Systems – Receiving signals from guard door switches, emergency stop pushbuttons, and safety light curtains (when integrated with appropriate safety controllers)
Remote I/O Networks – Deploying in distributed I/O architectures using 1794-ASB (Remote I/O), 1794-AENT (EtherNet/IP), 1794-ADN (DeviceNet), or 1794-APBDPV1 (PROFIBUS) adapters
Hazardous Area Installations – Suitable for Class I Division 2 and ATEX/IECEx Zone 2 environments when mounted in appropriately rated enclosures
8 Sinking DC Inputs – Accepts 24V DC signals from sourcing field devices with 2.0 mA minimum on‑state current
Wide Operating Voltage Range – Supports 10…31.2V DC, accommodating variations in field power supplies and cable voltage drops
Programmable Input Filtering – Eight selectable filter times (0.25 to 32 ms) via configuration bits to reject contact bounce and electrical noise
Flexbus Backplane Connection – Interfaces to the I/O backplane through the Flexbus connector for high‑speed data exchange with the adapter or neighboring modules
Hazardous Location Approvals – Certified for Class I Division 2 Groups A-D, ATEX/IECEx Zone 2 (Ex ec IIC T3 Gc), and CCC Ex for global deployment
Flexible Wiring Options – Supports 2‑wire and 3‑wire field devices (limit switches, proximity sensors, photoelectric sensors) with clear terminal numbering
Compact Modular Form Factor – Occupies a single FLEX I/O terminal base slot, maximizing panel density and simplifying system expansion
Diagnostic LED Indicators – Individual input status LEDs provide real‑time visual indication of each channel‘s ON/OFF state
Wide Temperature Operation – Operates from –20°C to +55°C, suitable for demanding industrial environments
Terminal Base Keying – Keyswitch (position 2) ensures correct module installation and prevents improper insertion
High I/O Density in a Compact Footprint – The 8‑point design provides efficient channel count per slot, reducing overall system hardware costs and panel space requirements compared to lower‑density alternatives.
Global Hazardous Area Approvals – With c‑UL‑us Class I Division 2, ATEX/IECEx Zone 2 (Ex ec IIC T3 Gc), and CCC Ex certifications, the 1794‑IB8 simplifies system design for international projects requiring compliance with multiple safety standards.
Flexible Adapter Compatibility – Works seamlessly with a wide range of communication adapters—Remote I/O, ControlNet, DeviceNet, EtherNet/IP, and PROFIBUS—enabling integration into virtually any distributed I/O network architecture.
User‑Configurable Input Filtering – Eight selectable filter times allow precise tuning to match specific application needs, reducing false triggers from contact bounce or electrical noise without sacrificing response speed.
Dual‑wire and Three‑wire Support – Accepts both 2‑wire (signal + supply) and 3‑wire (signal + supply + common) field devices, providing flexibility for mixed sensor types in a single module.
Robust Industrial Design – Rated for –20°C to +55°C operation, 5‑95% humidity, and altitudes up to 2000 m, the module is built to withstand harsh factory floor conditions without derating.
Simplified Wiring and Maintenance – Clear terminal numbering and individual status LEDs accelerate installation, commissioning, and troubleshooting, reducing mean time to repair (MTTR).
TÜV Functional Safety Certified (1794‑IB16) – While the 1794‑IB8 is not TÜV SIL‑rated, the 1794‑IB16 variant offers SIL 2 capability, demonstrating Rockwell‘s commitment to safety and allowing for system‑wide safety integration using similar form‑factor modules.
|
Item |
Catalog Number / Part |
Description |
|
Replacement Module |
1794-IB8 |
Direct replacement for a failed or worn-out input module. |
|
Terminal Base (Screw Clamp) |
1794-TB3 |
Mounting base for field wiring connections; uses screw-type terminals. |
|
Terminal Base (Spring Clamp) |
1794-TB3S |
Mounting base for field wiring; uses spring-clamp terminals for faster wiring. |
|
Remote I/O Adapter |
1794-ASB (Series E or later) |
Interfaces the module to a Remote I/O network. |
|
EtherNet/IP Adapter |
1794-AENT (Series A, firmware ≥2.4) |
Provides EtherNet/IP connectivity for the I/O rack. |
|
DeviceNet Adapter |
1794-ADN (Series B, firmware ≥2.4) |
Enables DeviceNet network integration. |
|
PROFIBUS Adapter |
1794-APBDPV1 (Series B GSD) |
Connects the module to a PROFIBUS network. |
|
ControlNet Adapter |
1794-ACN15 (Series C, firmware ≥4.1) |
Provides ControlNet communication for the FLEX I/O system. |
|
DIN Rail (Steel) |
— |
Zinc-plated chromate-passivated steel rail; secure to mounting surface every 200 mm; use end anchors. |
|
Keyswitch |
— |
Set to position 2 on the terminal base for proper module keying. |
|
Programming Software |
Studio 5000 Logix Designer (v20 or later) |
Required for module configuration and filter-time setting. |
|
Documentation |
1794-IN093 (Installation Instructions) |
Detailed wiring, mounting, and configuration guidelines. |
|
Grounding Guidelines |
1770-4.1 (Industrial Automation Wiring and Grounding) |
Covers proper grounding and noise immunity practices. |
|
Dummy Cover (for empty slots) |
— |