BENTLY NEVADA | 24701 SERIES
24701-28-05-XX-023-04-XX MOD:323933-30-02
Modified Stainless Steel Proximity Probe Housing Assembly
|
|
Selection: 3300 XL 8 mm probe with approval option | 0.5 m cable | 2.3 in probe penetration | one 3/4-14 NPT plug | modification 323933-30-02
LEAD TIME: In stock | WARRANTY: 1 year
|
OFFICIAL PRODUCT SUMMARY
24701 Stainless Steel Proximity Probe Housing Assembly
An all-metal externally mounted proximity probe housing assembly with a 303 stainless steel body, 304 stainless steel sleeve and installed reverse-mount proximity probe. The assembly provides external access for probe gap adjustment or replacement without machine disassembly.
|
Exact configuration: Option 28 selects a 3300 XL 8 mm probe with approval option; 05 selects a 20 in (0.5 m) probe cable; 023 selects 2.3 in probe penetration; 04 selects one 3/4-14 NPT plug. The XX fields and MOD 323933-30-02 are modification-controlled and are not decoded in the public datasheet. |
|
Technical Data
Official 24701 housing data and decoded public order-code fields
|
|
Complete model
|
24701-28-05-XX-023-04-XX MOD:323933-30-02
|
|
Product family
|
24701 Proximity Probe Housing Assembly
|
|
Product type
|
Modified stainless steel externally mounted proximity probe housing assembly with installed reverse-mount probe
|
|
Dimensions
|
24701 base housing: A 78.2 mm (3.08 in), B 151.9 mm (5.97 in), E 27.9 mm (1.10 in); selected probe penetration D is 2.3 in (58.4 mm); standoff C and mounting thread F are represented by XX and controlled by the modification
|
|
Weight
|
1.8 kg (4.1 lb) typical for 24701 housing without fittings
|
|
Housing material
|
303 stainless steel body with 304 stainless steel sleeve
|
|
Probe selection
|
Option 28: 3300 XL 8 mm probe with approval option
|
|
Probe cable length
|
Option 05: 20 in (0.5 m)
|
|
Probe penetration
|
Option 023: 2.3 in (58.4 mm), adjustable by 13 mm (+/- 0.5 in)
|
|
Fitting selection
|
Option 04: one 3/4-14 NPT plug only
|
|
Standoff adapter
|
XX: modification-controlled value; not defined in the public ordering table
|
|
Mounting thread
|
XX: modification-controlled value; not defined in the public ordering table
|
|
Probe operating and storage temperature
|
3300 XL 8 mm probe: -51 to +177 deg C (-60 to +351 deg F)
|
|
Housing compliance
|
API 670 compliant for externally mounted proximity probe housings; RoHS Directive 2011/65/EU
|
|
Hazardous-area selection
|
Probe option 28 includes an approval option; exact installed approvals must follow the product marking and official approvals guide
|
|
Modification
|
MOD 323933-30-02; modification details are not published in datasheet 141600
|
|
CONTACT
STELLA
|
|
Construction
|
|
All-metal housing
The 24701 assembly uses a 303 stainless steel body and a 304 stainless steel probe sleeve.
|
Service access
The threaded dome cover permits external access for probe adjustment or replacement without dismantling the machine.
|
|
Installed sensing element
Option 28 supplies a reverse-mount 3300 XL 8 mm proximity probe with an approval option.
|
Conduit interface
The selected fitting option supplies one 3/4-14 NPT plug; the mounting interface remains modification-controlled.
|
|
Key selection note: The public datasheet does not decode the two XX fields or the mechanical details of MOD 323933-30-02.
|
|
|
Part number breakdown
24701-28-05-XX-023-04-XX MOD:323933-30-02
|
|
24701
|
Stainless steel proximity probe housing assembly
|
|
28
|
3300 XL 8 mm probe with approval option
|
|
05
|
20 in (0.5 m) probe cable
|
|
XX
|
Modification-controlled standoff adapter value
|
|
023
|
2.3 in probe penetration
|
|
04
|
One 3/4-14 NPT plug only
|
|
XX
|
Modification-controlled mounting thread value
|
|
MOD 323933-30-02
|
Customer or project modification reference; details not published in document 141600
|
|
Installation
|
|
Mounting location
Use for external mounting through the machine case with access to the probe and lead from outside the machine.
|
Penetration setting
The selected 2.3 in penetration has an official adjustment range of 13 mm (+/- 0.5 in).
|
|
Sleeve support
If the final standoff plus penetration dimension exceeds 12 in (300 mm), provide additional sleeve support to prevent resonance.
|
Probe lead
The probe lead must be longer than the installed sleeve, and routing must preserve service access under the dome cover.
|
|
Key selection note: Confirm the modification-controlled standoff and mounting thread from the physical nameplate or approved modification drawing before machining the installation.
|
|
|
Environment & Approvals
Published family limits and compliance information
|
|
Probe temperature
|
3300 XL 8 mm probe operating and storage: -51 to +177 deg C
|
|
Housing material
|
303 stainless steel body; 304 stainless steel sleeve
|
|
Environmental enclosure
|
24701 housings are available as CSA Type 4 enclosure configurations
|
|
API compliance
|
API 670 compliant for externally mounted proximity probe housings
|
|
RoHS compliance
|
European Community RoHS Directive 2011/65/EU
|
|
Approval selection
|
Option 28 provides a selectable hazardous-area approval probe configuration
|
|
Explosion-proof distinction
|
Only CA24701 configurations ordered under the applicable CSA conditions are identified as explosion-proof in the public datasheet
|
|
Six checks before purchase
|
|
1. How can the quoted complete model be verified?
Require the quotation, nameplate and packaging to show 24701-28-05-XX-023-04-XX together with MOD:323933-30-02. Confirm option 28, 0.5 m cable, 2.3 in penetration and fitting option 04 independently.
|
|
2. How can New, Used or Refurbished condition be distinguished?
Inspect the stainless steel housing, dome-cover threads, probe tip, sleeve, cable, plug and internal surfaces. A new assembly should not show probe rub, thread witness marks, corrosion, cut cable, oil residue or previous installation marks.
|
|
3. How can supplier legitimacy and reliability be checked?
Verify the supplier legal entity, physical address, bank beneficiary, traceable quotation and written condition statement. The supplier should identify both the complete 24701 code and MOD 323933-30-02 on all commercial documents.
|
|
4. What must engineers check before purchase?
Check the 303 stainless housing, 304 stainless sleeve, 3300 XL 8 mm probe, 0.5 m cable, 2.3 in penetration, one 3/4-14 NPT plug, required approvals and the modification-controlled standoff and mounting thread.
|
|
5. What physical evidence should be requested before payment?
Request dated photos of the full nameplate, modification marking, probe tip, sleeve, cable, dome cover and plug, plus measured evidence of the 2.3 in penetration and any drawing or inspection record that defines both XX fields.
|
|
6. Can a similar 24701 suffix or modification replace this model?
No automatic substitution is valid. Changes to probe type, cable length, standoff, penetration, fittings, mounting thread or MOD reference can alter fit, approvals and installation geometry. Match every code segment and the modification drawing.
|
|
Random cross-brand reference list
|
|
76714
|
MU-A30VD-K1 E12948451
|
TT260
|
|
2791
|
MAC01.431
|
F0101000070-D
|
|
1609C39G-01
|
ABB BA-M-0.4.1 2cdg510011R0011
|
TC806D1056
|
|
J9736A 2920/2930M
|
DFC-322R3-240
|
HEIE420269R1 DC374a
|
|
SXWAUTSVR10001
|
IE-3000-8TC
|
XRE2024D
|
|
QSWE-BULK-CCI
|
ST600MP0005
|
HCD2-FBPS-1.500
|
|
FO-BP-1001 FO-IH-1002
|
MS-VMA1630-1
|
61-000163-02
|
|
2182-227
|
ABB AI523 1SAP450300R0001
|
MSR142RTP 440R-G23215
|
|
99-3012-1100
|
ABB 1SAP250600R0001 AI531 1SAP212200R0101
|
WV-U2530L
|
|
CX1020-0121 CX1020-N000 CX1020-N010
|
L0055994 GJR5251400R3202
|
ABB SNAT4041
|
|
GRX-TVM-ISO2 GRX-TVM2
|
XSRING-2400
|
ABB Sv / S 30.640
|
|
SPS-A2D24A
|
3RH2140-1BG40
|
9407 489 60001 KS800-CAN
|
|
TBS100
|
1766-L32BWA /B
|
PX-Q120
|
|
ABB 2CDG110101R0011
|
23001-069
|
EN300
|
|
DR4208SGM
|
CH5 00N0M356C1
|
330106-05-30-05-02-CN
|
|
IC200MDL650K
|
SB-4Z-UN
|
852-907-001
|
|
ABB, 1SAJ520000R0201, UMC100-FBP.0
|
DNS - D606MW
|
EST3
|
|
MDR-60-24
|
F2108
|
440-443
|
|
025L03042-00
|
RS-485 101-0020
|
779153-001
|
|
V5862A3011
|
371-03785-001 RS232-LAN
|
ABB 6197/51-515
|