emerson deltav m series series 2 kj3222x1 ba2 8 channel 4 20ma hart analog input card-0

EMERSON Delta V

Home >  Products >  EMERSON >  EMERSON Delta V

Emerson DeltaV M-series Series 2 KJ3222X1-BA2 8-Channel 4-20 mA HART Analog Input Card

Emerson DeltaV M-series Series 2 8-Channel 4-20 mA HART Analog Input Card for Earlier DeltaV Versions
Complete Model
KJ3222X1-BA2
Official Product Description
Emerson KJ3222X1-BA2 DeltaV M-series Series 2 eight-channel 4-20 mA HART analog input card specified for earlier DeltaV version compatibility.
CORE FEATURE: Eight 4-20 mA HART inputs with the BA2 compatibility suffix for earlier DeltaV installations.
LEAD TIME: In stock
WARRANTY: 1 year

Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • Applications & Features
  • Connections
  • Installation
  • Environment
  • FAQ
  • Recommend Models
  • Recommended Products
Product Overview
KJ3222X1-BA2 is an Emerson DeltaV M-series Series 2 eight-channel 4-20 mA HART analog input card.
The current Emerson PDS states that installations earlier than DeltaV v10.3.1 should request KJ3222X1-BA2, distinguishing this suffix from BA1 for compatibility planning.
The exact July 2021 instruction sheet identifies 12 VDC LocalBus power at 150 mA, 24 VDC bussed field power at 300 mA, 30 mA field circuits, A1 keying and a -40 to +70 degrees C ambient range.

Technical Data

Complete model
KJ3222X1-BA2
Brand
Emerson
Product family
DeltaV M-series Series 2 Traditional I/O
Product type
8-channel 4-20 mA HART analog input card for earlier DeltaV version compatibility
Number of channels
8
Nominal input range
4 to 20 mA
Full input range
1 to 22.5 mA with overrange checking
HART support
HART pass-through for AMS Device Manager; variables and status available for control functions
Accuracy over temperature
0.1 percent of span
Resolution
16-bit A/D converter
Repeatability
0.05 percent of span
Frequency response
-3 dB at 2.7 Hz; -20.5 dB at one-half sampling frequency
HART scan time
600 to 800 ms typical per enabled channel
Isolation
Each channel optically isolated from the system and factory tested to 1500 VDC
LocalBus power
12 VDC at 150 mA on the exact BA2 instruction sheet
Bussed field power
24 VDC at 300 mA
Field-circuit rating
24 VDC at 30 mA per channel
Terminal-block key
A1
DeltaV compatibility note
Emerson PDS directs systems earlier than DeltaV v10.3.1 to request KJ3222X1-BA2
Dimensions
10.7 x 4.1 x 10.5 cm, height x width x depth
Weight
Not specified in the official sources reviewed
Protection rating
IP20 component
Operating temperature
-40 to +70 degrees C
Certifications
FM19ATEX0173U; IECEx FMG 19.0019U; FM21UKEX0017U; FM Class I Division 2 and Zone 2, subject to the exact product label
Official sources
Emerson instruction sheet ATEX228 page 1; DeltaV M-series Traditional I/O PDS pages 4, 5, 26, 28 and 29

Inquiry

Applications & Features

Eight HART inputs
Eight 4-20 mA channels support HART device communication and diagnostic data.
Earlier-version compatibility
The current PDS specifically identifies BA2 for DeltaV software earlier than v10.3.1.
High-resolution measurement
The published family performance is 16-bit conversion with 0.1 percent span accuracy.
A1 keyed interface
The exact BA2 instruction sheet specifies A1 terminal-block keying.

Connections

Analog inputs
Eight 4-20 mA HART channels with a 1 to 22.5 mA full range.
LocalBus
12 VDC at 150 mA on the exact BA2 instruction sheet.
Bussed field power
24 VDC at 300 mA.
Channel circuit
24 VDC at 30 mA per channel.
Terminal block
Use compatible A1-keyed terminal hardware approved for the installed earlier DeltaV version.
HART access
Confirm AMS Device Manager pass-through and controller-version support before commissioning.

Installation

01 - Verify the BA2 suffix
Match KJ3222X1-BA2 on the product label, quotation and dated photos; do not shorten it to BA1.
02 - Check DeltaV version
Confirm that the installed software version and I/O database require the BA2 compatibility variant.
03 - Confirm A1 keying
Use only compatible A1-keyed terminal hardware approved for the selected system version.
04 - Validate signal and power
Confirm eight 4-20 mA HART inputs, field-power budget, channel current limit, polarity and transmitter wiring.
05 - Follow BA2 removal rules
The exact ATEX228 sheet states that system power must be de-energized before removing or inserting this card.

Environment

Ambient temperature
-40 to +70 degrees C on the exact instruction sheet.
Storage temperature
-40 to +85 degrees C in the current M-series Traditional I/O data sheet.
Protection
IP20 component; install in the enclosure required by the site and certification.
Relative humidity
5 to 95 percent, non-condensing.
Shock
10 g half-sine wave for 11 ms.
Airborne contaminants
ISA-S71.04-1985 Class G3 with conformal coating.
Maintenance
No user-serviceable parts; calibration is not required unless the exact card documentation states otherwise.

FAQ

Q1. How can the exact quoted KJ3222X1-BA2 be verified?
Match the complete KJ3222X1-BA2 suffix on the label, quotation and dated photos. Confirm eight HART analog inputs and A1 keying.
Q2. How can New, Used or Refurbished condition be distinguished?
Request current photos of the full BA2 label, A1 keying, contacts, indicators, housing and packaging. Check for insertion wear, repair residue, altered approval markings or replaced labels.
Q3. How should supplier legality and reliability be checked?
Verify the supplier legal entity, registered address, payment beneficiary and traceable contact. The offer must state KJ3222X1-BA2 without substituting BA1.
Q4. Which specifications must engineering confirm before purchase?
Confirm DeltaV software version, BA2 compatibility requirement, eight 4-20 mA HART inputs, A1 termination, 16-bit conversion, power limits and removal procedure.
Q5. What physical evidence should be requested before payment?
Ask for date-marked photos showing the complete BA2 nameplate, serial data, A1 key position, front indicators, rear contacts, terminal interface and sealed packaging when offered as new.
Q6. Can a different suffix replace KJ3222X1-BA2?
Not without a compatibility review. The official PDS assigns the BA2 suffix to earlier DeltaV versions. Verify the controller software and terminal block before changing to any other suffix.

Recommend Models

GE CR2960SY139C3C
DEV-5
Ti300
FVR8018S
4T-6-PSG 3M/S1584/SV
701N5B3B
NBC13-5.0-AA
330750-60
9253C03H06
AR880A
DN-Q12-2-2-A
1621-0074-00
71-208-IMG6
SL10VB6VQ
A-5000-3712
FX-A1 UFXA1
IP20 - PCS030Y4IP20P
AB42-03-7-02HH-DC24V
CR120B
8564E
1771-WD
8MX-39S-12
MDO3032
CR120B04022
2604600B33MA
CNMG190612-TH T9025
M22-IY1-PG
028249-001
P211SC-024-D
63-1008-AL-02B
QRS411
NT0317-1
VG-253K-S-12-MC
74115-0115
PMKG-JLP 347485-000
LNR86-1E NEMA 5-15R
6SE7026-0ED61-Z
576454
N88471
K105A04531
SCT-1250-400
DRTS-6
IC693ACC300C
PPD-S-V01AHN-HS
SL1-HFYC2
NFCP502-W15
3TF4422-0A
819-99-D-10 0432HU
ZB4BVB3
3LD9250-2C
GE IS200TDBTH6ACD
082SS53BM
FT13P-3.6
WIC-012
E162205-K
0882400
WMZT1D01
Notifier ID3000
3950 X 341855-1-1
C3-510

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000