LEAD TIME: In stock
|
WARRANTY: 1 year
|
|
Complete model
|
VE4035S2B4
|
|
Brand
|
Emerson
|
|
Product family
|
DeltaV M-series Traditional I/O
|
|
Product type
|
16-channel 4-20 mA HART analog output Plus interface with redundant 16-channel AO terminal block for Series 2 Plus
|
|
Number of channels
|
16
|
|
Nominal signal range
|
4 to 20 mA
|
|
Full signal range
|
1 to 23 mA
|
|
Isolation
|
Each channel is optically isolated from the system and factory tested to 1000 V DC
|
|
LocalBus current
|
Redundant: 110 mA typical; 260 mA maximum per card at 12 V DC nominal
|
|
Field circuit power
|
400 mA maximum at 24 V DC, plus or minus 10 percent
|
|
Accuracy over temperature
|
0.25 percent of span
|
|
Resolution
|
14-bit A/D converter
|
|
Output compliance
|
Not specified in the official March 2026 product data sheet
|
|
Calibration
|
None required
|
|
HART support
|
HART pass-through for AMS Device Manager; HART variable and status reporting for control functions; 600 to 800 ms typical scan time per enabled channel
|
|
Termination
|
Redundant 16-channel AO terminal block for Series 2 Plus
|
|
I/O card keying
|
A5
|
|
Software or architecture
|
DeltaV Series 2 Plus traditional I/O architecture
|
|
Dimensions
|
10.7 x 4.1 x 10.5 cm, height x width x depth; 4.2 x 1.6 x 4.1 in
|
|
Weight
|
Not specified in the official March 2026 product data sheet
|
|
Protection rating
|
IP20
|
|
Operating temperature
|
-40 to 70 degrees C (-40 to 158 degrees F)
|
|
Storage temperature
|
-40 to 85 degrees C (-40 to 185 degrees F)
|
|
Relative humidity
|
5 to 95 percent, non-condensing
|
|
Certifications
|
CE, FM, cFM, CSA, ATEX, IECEx, IACS E10, ABS and DNV options; verify actual markings
|
|
Official source
|
Emerson DeltaV M-series Traditional I/O Product Data Sheet, March 2026, pages 4, 12, 26, 28 and 30
|
|
Output channels
|
16 field outputs with a nominal 4-20 mA span and a full 1-23 mA signal range.
|
|
HART communication
|
HART pass-through for AMS Device Manager; HART variable and status reporting for control functions; 600 to 800 ms typical scan time per enabled channel.
|
|
Field power
|
400 mA maximum at 24 V DC, plus or minus 10 percent.
|
|
Termination
|
The two-wide redundant terminal block lets the controller recognize a redundant card pair and supports automatic active-to-standby switchover.
|
|
Redundancy
|
Emerson describes redundant cards on a two-wide terminal block as an automatically recognized active-and-standby pair, with switchover completed within two I/O-bus scans.
|
|
EE8345P001M0
|
SEL-3530 3530AA2XX313x1XXXXXX
|
CSTVP-1502-CF-S12
|
|
NCDQ2A50-6DZ
|
E22C9T、E22C7T
|
ABB 3BHE009681R0101 GVC750BE101
|
|
R14-200-R20A
|
140DRC83000
|
D26MB
|
|
VSC12
|
RSP-150-24
|
FAZ-C15/1-NA
|
|
GE P111-6053
|
5000118-698X
|
OG3-FR 9414-OE
|
|
GV2-RS04
|
6MD6130-4FB90-0AA0
|
90190T
|
|
9905-863
|
3LD9221-0A
|
48EC37AA3
|
|
AMTPM-B AMT
|
741150115 3A307
|
672B770G07
|
|
A30QS300-4
|
82A-0A-BRA
|
AR9B290
|
|
SY5A00-5Z1
|
2982728 PLC-OSC-24DC/TTL
|
UNEF-2A
|
|
DV-20-1.1/5-V
|
M10A6-AN
|
165-00/130-10-C/170-00/115V
|
|
2000-5420/1399-987
|
FTH-410
|
SDR-120-24
|
|
EPR60
|
500L-DOD930
|
14-956-1D
|
|
800TC-XA4
|
COM-120C
|
BC-ATS-151510
|
|
XB3BK3333
|
Is200tbtch1b
|
B3DA9100
|
|
025-40496-002 025-40496-003
|
FE7C-FRF6
|
GE CR120B100
|
|
200-530-026-014
|
SZL-VL-SDNM
|
2190-E21PA
|
|
LP-9473
|
V61R517A-A213JB
|
700-HLS1Z48
|
|
XC3S1500 FG676AFQ0433
|
ZCP21
|
CL-C360W-24V
|
|
2947A
|
120-904S1
|
JA1-A8-A
|