Overview

Brand Name:

SIEMENS

Model Number:

6DP1210-8BC

Country of Origin:

GERMANY

Packaging Details:

Original new Factory Sealed

Delivery Time:

Delivery time in stock

Payment Terms:

T/T

Contact for quotation

Sales Manager:

Stella

Send an email:

[email protected]

Contact in Whatsapp:

+86 18159889985

Specifications

Parameter

Specification

Manufacturer

Siemens

Model Number

6DP1210-8BC (FUM210 Functional Module)

System Compatibility

TELEPERM XP Automation System / AS 620 B

Module Functions

Binary signal conditioning (BT), high-speed binary acquisition (BT-1), individual drive control (ESG), binary signal output (F210BIN), monitoring and signalling

Binary Inputs

28 input channels (various sensor/contact types)

Binary Outputs (F210BIN)

16 outputs

Sensor Supply Outputs

14 short-circuit and overload-proof driver outputs

Input Protection

Static destruction limit 33 V; switching voltage up to 45 V (for contact types without bridging resistors)

Signal Delay (Hardware)

Typical 3 ms

Software Delay

0 to 10 s, configurable in 0.1 s steps

Operating Voltage

+5 V (internal), 24 V DC (external supply via backplane)

Fuse

FF 4A (super quick), replaceable from front panel

Module Format

Extended double Eurocard 233×220 mm for ES 902C packaging system

Slot Width

20.32 mm (1 1/3 standard slots)

Front Panel

Metallic, width 20 mm, height 230.35 mm

Connectors

Upper X1 (96-pin, C-style, bus interface), Lower X5 (64-pin, G-style, I/O interface)

Dimensions (approx.)

265 × 210 × 21 mm (H×D×W)

Weight (approx.)

0.4 kg

Order Number

6DP1210-8BC

Description

The Siemens 6DP1210-8BC is a versatile FUM210 function module for the TELEPERM XP AS 620 B automation system. It supports three distinct operational modes: binary signal conditioning (BT function), high-speed binary signal acquisition (BT-1), and individual drive control (ESG function). This 6DP1210-8BC module also features binary signal output (F210BIN) and monitoring/signaling capabilities. With 28 binary inputs and 16 outputs, the Siemens 6DP1210-8BC provides short-circuit-proof sensor supply, configurable signal delays, and seamless bus communication through two redundant interfaces, ensuring reliable process control in industrial environments【14†L4-L7】【18†L14-L19】.

Applications

Binary signal conditioning and high-speed acquisition from field sensors and proximity switches

Individual drive control for motors, solenoid valves, actuators, switchgears, and reversing drives (up to 17 drive types)【26†L5-L31】

Master monitoring and signalling in I&C cabinets (fault detection, cabinet indicator lamps, door contacts)【14†L14-L17】

Replacement of SYS900 monitoring module in AS 620 B automation systems【14†L11-L12】

Binary signal output for process control via PAA_E【18†L16-L17】

Features

High flexibility: No fixed hardware-to-channel assignment; free combination of drive types and I/O resources【27†L1-L5】

Three operational modes: Binary signal conditioning, high-speed binary acquisition, individual drive control【14†L4-L7】

28 sensor inputs: Support for changeover/single contacts and 3‑/4‑wire proximity switches【19†L2-L9】

16 binary outputs: Reverse voltage and back‑e.m.f. protected with automatic reclosing【18†L14-L17】

14 sensor supply outputs: Short-circuit and overload-proof, monitored by module processor【18†L10-L12】

Configurable signal delays: Hardware delay 3 ms; software delay 0 ~ 10 s (0.1 s steps)【20†L4-L8】

Comprehensive diagnostics: CPU, EPROM, RAM, bus interface self-tests and DS670 diagnosis【22†L1-L10】

Functions

Binary signal acquisition (28 channels, 6 sensor contact types)【19†L2-L9】

Sensor supply output (14 drivers, short-circuit and overload-proof)【18†L10-L12】

Binary signal output (16 channels) for control commands (F210BIN function)【18†L14-L17】

Individual drive control (ESG function) covering 17 drive types from simple motors to reversing drives【26†L7-L31】

Monitoring and signalling (cabinet fault detection, lamp triggering, acknowledgement processing)【14†L14-L17】

Dynamisation of fault signals (blinking for new faults, steady for acknowledged)【14†L17-L19】

Signal inversion (NC contact sensing) and common alarm output【15†L2-L5】

Startup self-tests (CPU, EPROM, RAM, bus interfaces) and cyclic operation after parameterization【21†L4-L14】

FAQ

Q1: What are the main operational modes of the Siemens 6DP1210-8BC?
A1: The 6DP1210-8BC supports binary signal conditioning (BT), high-speed binary acquisition (BT-1), individual drive control (ESG), binary signal output (F210BIN), and monitoring/signalling functions【14†L4-L7】.

Q2: How many binary inputs does the Siemens 6DP1210-8BC provide for sensor acquisition?
A2: The 6DP1210-8BC provides 28 binary input channels capable of processing changeover contacts and single contacts, with or without 47 kΩ bridging resistance, as well as standard binary signals from proximity switches【19†L2-L9】.

Q3: Can the Siemens 6DP1210-8BC be used for drive control applications?
A3: Yes, the 6DP1210-8BC supports individual drive control for up to 17 drive types, including motors, solenoid valves, actuators, servo-drives, and reversing drives, with flexible assignment of binary I/O resources【26†L5-L31】.

Q4: What configuration or adjustment is required before using the Siemens 6DP1210-8BC?
A4: The 6DP1210-8BC can be used without presetting; the higher-level AP automatically recognizes the module upon insertion and initializes it if a suitable parameter record exists. Only the front-panel fuse must be removed before insertion/removal【21†L19-L26】.

Q5: How does the Siemens 6DP1210-8BC indicate module faults?
A5: Faults detected by the 6DP1210-8BC are entered into the PAE_E process image, transferred as TTDs to the process control level, and indicated by a flashing "Module fault" LED【23†L15-L19】【35†L28-L32】. Comprehensive diagnostics are available via the DS670 system【22†L1-L10】.