honeywell experion series c cc tdil01 non redundant 24 vdc digital input iota original new-0

DCS

Home >  Products >  HONEYWELL >  DCS

Honeywell Experion Series C CC-TDIL01 Non-Redundant 24 VDC Digital Input IOTA | Original New

HONEYWELL | EXPERION PKS SERIES C
CC-TDIL01
Non-Redundant 24 VDC Digital Input IOTA
9-inch IOTA | 32 discrete input channels | 18 to 30 VDC | Optical isolation | Open-wire detection
LEAD TIME: In stock
WARRANTY: 1 year
Appurtenance
  • Overview
  • Technical Data
  • Inquiry
  • Input Architecture
  • Signal Thresholds
  • Diagnostics
  • Installation
  • FAQ
  • Recommend Models
  • Recommended Products
CC-TDIL01
Honeywell Experion PKS Series C Non-Redundant 24 VDC Digital Input IOTA
Product family
Honeywell Experion PKS Series C I/O
Key specifications
9-inch non-redundant IOTA | 32 channels | 18 to 30 VDC | 1500 VAC RMS or +/-1500 VDC galvanic isolation
Documentation basis
Honeywell Experion Series-C I/O Specification EP03-490-520, Version 1.5, page 29

Technical Data

Complete model
CC-TDIL01
Product family
Honeywell Experion PKS Series C I/O
Product type
Non-redundant 24 VDC Digital Input IOTA
Dimensions
9-inch IOTA form factor
Weight
Not specified in the official Honeywell documents reviewed
Redundancy
Non-redundant
Compatible IOMs
CC-PDIL01 24 VDC Digital Input and CC-PDIS01 Digital Input Sequence of Events
Input channels
32
DI power voltage range
18 to 30 VDC
ON sense voltage/current
13 VDC minimum or 3 mA minimum
OFF sense voltage/current
5 VDC maximum or 1.2 mA maximum
Input impedance
4.2 kohms
Input filter and isolation delay
5 ms +/-20%
Isolation technique
Optical in the IOM
Galvanic isolation
1500 VAC RMS or +/-1500 VDC
Field resistance for guaranteed ON
300 ohms maximum at 15 VDC
Field resistance for guaranteed OFF
30 kohms minimum at 30 VDC

Input Architecture

32-Channel 24 VDC Input Termination
CC-TDIL01 is the 9-inch non-redundant IOTA used with the Series C CC-PDIL01 or CC-PDIS01 input module. It terminates 32 discrete 24 VDC input channels and supports internal or external field-power selection.

Signal Thresholds

Defined ON and OFF States
The official input thresholds are 13 VDC or 3 mA minimum for the ON state and 5 VDC or 1.2 mA maximum for the OFF state. The 4.2 kohm input impedance and 5 ms input-filter delay must be included in field-circuit checks.

Diagnostics

Open-Wire and Data Integrity Monitoring
With the supported Series C input module, the architecture provides internal diagnostics and open-wire detection. An input value associated with an open-wire diagnosis is reported invalid so that control logic does not treat the value as trustworthy.

Installation

IOTA Selection and Field Wiring
Confirm the complete CC-TDIL01 label, the 9-inch non-redundant footprint, the installed CC-PDIL01 or CC-PDIS01 module, channel numbering and field-power source. Do not substitute the 12-inch redundant CC-TDIL11 without verifying cabinet layout and redundancy design.

FAQ

1. How can the buyer confirm that the quoted item is exactly CC-TDIL01?
Verify the complete CC-TDIL01 code on the Honeywell label and confirm a 9-inch non-redundant 24 VDC digital input IOTA. The associated design must provide 32 input channels and match a CC-PDIL01 or CC-PDIS01 IOM.
2. How can New, Used or Refurbished condition be distinguished for CC-TDIL01?
Request current images of the full label, both sides of the IOTA, terminal blocks and connector area. Check for terminal wear, repaired traces, residue, altered labels, missing hardware or evidence of previous cabinet installation.
3. How should the supplier be checked before buying CC-TDIL01?
Verify the supplier legal entity, traceable invoice information and ability to identify CC-TDIL01 in Honeywell Series C documentation. The quotation should state the exact model, 9-inch non-redundant form, condition and included terminal hardware.
4. Which specifications should an engineer verify before ordering CC-TDIL01?
Confirm the installed CC-PDIL01 or CC-PDIS01 IOM, 32-channel requirement, 18 to 30 VDC input range, ON and OFF thresholds, 4.2 kohm impedance, field-power arrangement, isolation and terminal allocation.
5. What physical evidence should be requested before payment?
Ask for high-resolution photos and video showing the CC-TDIL01 model label, serial or revision data, terminal blocks, connector, fuse and power-selection areas, both board surfaces and the packing label.
6. Can CC-TDIL11 or another similar suffix replace CC-TDIL01?
Do not assume interchangeability. CC-TDIL01 is the 9-inch non-redundant version, while CC-TDIL11 is the 12-inch redundant version. Cabinet footprint, redundancy, terminal layout and IOM selection must match the installed system.

Recommend Models

1769-L33ER
1769-L27ERM-QBFC1B
PM591-ETH
TU844
ADV557
TB541-ETH
TK-PRR021
6ED1052-1FB08-0BA1
1756-L81EP
1769-L16ER-BB1B
1769-L18ERM-BB1B
1769-L30ER
1756-PB75
VE3007
6ES7332-5HD01-0AB0
6ES7288-2DR08-0AA0
1756-L905TS
ARS15M
CI502-PNIO
6ES7516-3FN02-0AB0
DO815
6ES7654-7HB00-0XA0
6GK7543-1AX00-0XE0
6ES7321-1BL00-0AA0
PM856K01
6ES7417-4HL04-0AB0
PM851K01
CC-GAIX21
TU843
AAR181
6ES7288-7ST40-0AA0
6ES7513-1RL00-0AB0
TU834
6ES7553-1AA00-0AB0
KJ4001X1-BE1
VE3011
VE4005S2B4
AO845A
CC-PAIX01
6ES7288-3AT08-0AA0
AI835A
6ES7407-0KA02-0AA0
CI522-MODTCP
CC-TCNT01
CC-TAIX11
TU839
6ES7274-1XH30-0XA0
6ES7332-5HF00-0AB0
SD834
VE4001S2T1B1
DA502
TB521-ETH
6ES7231-5ND32-0XB0
1756-EN3TR
6ES7590-1AB60-0AA0
ADV159
DI561
VE3008
PM858K01
6ED1052-1FB08-0BA2

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000