Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000
l34213500 system interconnection cable terminating on ftas ready for ship-0

FSC (Fail Safe Controller)

Home >  Products >  HONEYWELL >  FSC (Fail Safe Controller)

Honeywell FS-SICC-0001/L3(4213500) System Interconnection Cable terminating on FTAs Ready For Ship

Product Name:System Interconnection Cable terminating on FTAs

Brand Name:Honeywell

Model Number:FS-SICC-0001/L3(4213500)

Country of Origin: USA

Warranty: 12 Months

Whatsapp+86 18159889985

Email[email protected]

Appurtenance:
  • Overview
  • Contact for quotation
  • Specifications
  • Description
  • Applications
  • Features
  • Functions
  • FAQ
  • Spares
  • Recommended Products

Overview

Brand Name:

Honeywell

Model Number:

FS-SICC-0001/L3(4213500)

Country of Origin:

USA

Packaging Details:

Original new Factory Sealed

Delivery Time:

in stock

Payment Terms:

T/T

Contact for quotation

Sales Manager:

Stella

Send an email:

[email protected]

Contact in Whatsapp:

+86 18159889985

Specifications

Parameter Specification
Product Model FS-SICC-0001/L3 (4213500)
Product Type System Interconnection Cable
Cable Application SM Chassis IO to FTA Connection
Connector Type IO Connector + 20-Pin FTA Connector
Cable Construction Double Shielded
Conductor Size 20 × AWG 22 (0.34 mm²)
Outer Diameter 9.93 mm
Standard Cable Length 3.25 m
Available Lengths 3.25 m to 30 m
Signal Compatibility Digital and Analog I/O
Installation Type Backplane to FTA Interconnection
Shielding Protection High EMI/RFI Resistance
Safety Application Industrial Safety Systems
Operating Environment Industrial Automation
Approximate Weight 0.8 kg
Jacket Material Industrial Grade PVC
Compatible Modules TSAI-1620M, TSHART-1620M, SDI/SDO Series

Description

FS-SICC-0001/L3 (4213500)is a high-reliability system interconnection cable engineered for Safety Manager chassis I/O communication and Field Termination Assembly (FTA) connectivity. The cable provides secure signal transmission between Safety Manager I/O modules and FTAs through dedicated IO backplane connections, ensuring stable and efficient data exchange in mission-critical industrial automation systems.

TheFS-SICC-0001/L3features a rugged double-shielded cable structure with 20 × AWG 22 conductors, designed to minimize electromagnetic interference and maintain signal integrity in demanding industrial environments. Equipped with one IO connector and one 20-pin FTA connector, the cable supports fast installation and dependable integration with modules such asTSAI-1620M,TSHART-1620M, and various digital and analog I/O assemblies.

Compatible models includingFS-SICC-0001/L5,FS-SICC-0001/L10, andFS-SICC-0001/L30are widely used in Safety Manager controller systems, process automation platforms, and SIL-rated industrial safety applications. TheFS-SICC-0001/L3delivers reliable field-level connectivity, flexible cable routing, and long-term operational stability for industrial control networks.

Applications

  • Power plants:Connects safety I/O modules for turbine monitoring and relay protection systems.
  • Substations:Supports stable signal transmission between protection relays and field termination assemblies.
  • Chemical plants:Integrates process instrumentation with Safety Manager controller systems.
  • Oil & gas facilities:Provides reliable field communication in hazardous-area automation networks.
  • Steel mills:Maintains secure signal integrity under strong electromagnetic interference conditions.
  • Machinery manufacturing plants:Used for industrial automation cabinets and robotic control systems.
  • Water treatment facilities:Connects analog and digital process monitoring equipment within safety systems.

Features

  • Double-shielded industrial cable design
  • Stable signal transmission performance
  • Supports analog and digital I/O modules
  • High resistance to EMI and electrical noise
  • Flexible cable length configurations
  • Industrial-grade connector reliability
  • Compatible with Safety Manager FTAs
  • Simplified installation and maintenance

Functions

  • Connects I/O modules to FTAs
  • Transfers field-level control signals
  • Supports chassis IO communication architecture
  • Reduces signal interference in industrial systems
  • Enables secure backplane interconnection
  • Improves system wiring organization
  • Supports safety-critical automation applications
  • Maintains long-term communication stability

FAQ

Q1:What is the purpose of theFS-SICC-0001/L3cable?
A1:The cable connects Safety Manager chassis I/O modules to field termination assemblies for industrial signal transmission.

Q2:What type of shielding does theFS-SICC-0001/L3use?
A2:It uses a double-shielded cable structure to improve EMI and noise protection.

Q3:Which modules are compatible with theFS-SICC-0001/L3?
A3:The cable is compatible with various Safety Manager analog and digital I/O modules and FTAs.

Q4:What is the standard length of theFS-SICC-0001/L3cable?
A4:The standard version provides a cable length of approximately 3.25 meters.

Q5:In which industries is theFS-SICC-0001/L3commonly used?
A5:It is widely used in power generation, oil & gas, chemical processing, manufacturing, and industrial safety systems.

Spares

Number Description
SICC-0001/Lx System Interconnection Cable for Chassis IO Terminating on FTAs (SICC)
SICP-0001/Lx System Interconnection Cable for Chassis IO Terminating on Crimp Pins (SICP)
SICP-0002/L3 Digital Input Cable for Control Processor Backplane
SICC-1002/Lx System Interconnection Cable for Universal IO Terminating on FTAs (SICC)
SICC-2001/Lx System Interconnection Cable for Universal IO Terminating on FTAs (SICC)
CA-HWC300-AIO-DIO-xM System Interconnection Cable for Universal IO Terminating on IOTAs (SICC)

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000