Overview

Brand Name:

Honeywell

Model Number:

MU-TAIH12 51304337-100

Country of Origin:

USA

Packaging Details:

Original new Factory Sealed

Delivery Time:

in stock

Payment Terms:

T/T

Contact for quotation

Sales Manager:

Stella

Send an email:

[email protected]

Contact in Whatsapp:

+86 18159889985

Specifications

Parameter

Details

Model

MU-TAIH12 / 51304337-100

Type

High Level Analog Input / STI Module

Input Channels

16 channels

Signal Type

Analog / Smart transmitter input

Mounting Type

Rack-mounted I/O module

System Compatibility

Honeywell TPS / HPM / APM systems

Dimension (H x W x D)

Not specified (refer to system manual)

Weight

Not specified

Operating Voltage

24 Vdc system supply

Redundancy Support

Supported in paired configurations

Operating Environment

Industrial control applications

Description

TheMU-TAIH12 51304337-100High Level Analog Input / Smart Transmitter Interface module is engineered for reliable signal acquisition in advanced industrial automation systems. It enables accurate monitoring of multiple analog field signals and ensures stable integration within Honeywell’s distributed control architecture.

TheMU-TAIH12supports up to 16 input channels and is designed for high-performance process environments where precision, stability, and noise resistance are critical. It works seamlessly with related models such asMU-TAIH02andMU-TAIH13, providing scalable input solutions for both standard and redundant configurations.

As part of the Honeywell I/O family, includingMU-TAIH12and other HLAI series modules, this unit delivers dependable field signal conditioning, enhanced diagnostic capability, and robust operation in demanding industries such as power generation, petrochemical processing, and heavy manufacturing.

Applications

  • Power plants: Used for generator set monitoring and relay protection
  • Substations: Enables bus differential control and switchyard signal acquisition
  • Chemical plants: Supports automation and intrinsically safe monitoring systems
  • Steel mills: Ensures stable control in high temperature and EMI environments
  • Machinery manufacturing: Used in automated production lines and robotics control

Features

  • 16-channel high level analog input capability
  • Compatible with smart transmitter interface (STI) systems
  • High noise immunity for industrial environments
  • Supports redundant system architecture
  • Stable signal conversion and acquisition
  • Modular design for easy system integration
  • Designed for Honeywell TPS control platforms

Functions

  • Analog signal acquisition from field devices
  • Smart transmitter data communication
  • Signal conditioning and processing
  • Alarm and diagnostic monitoring
  • Real-time process variable transmission
  • Integration with distributed control systems

FAQ

Q1: What is MU-TAIH12 used for?
A1: It is used for collecting and processing high level analog signals in industrial control systems.

Q2: How many input channels does MU-TAIH12 support?
A2: It supports up to 16 analog input channels.

Q3: Can MU-TAIH12 work in redundant systems?
A3: Yes, it supports redundant configurations when paired with compatible modules.

Q4: Which industries use MU-TAIH12?
A4: It is widely used in power plants, chemical plants, steel mills, and manufacturing automation.

Q5: Is MU-TAIH12 compatible with Honeywell systems?
A5: Yes, it is fully compatible with Honeywell TPS, APM, and HPM control systems.

Spares

Number Describe
MU-TAIH02 High Level Analog Input/STI (Single IOP)
MU-TAIH03 High Level Analog Input (Single IOP)
MU-TAIH12 High Level Analog Input/STI
MU-TAIH13 High Level Analog Input
MU-TAIH22 Enhanced Power High Level Analog Input/STI
MU-TAIH23 Enhanced Power High Level Analog Input
MU-TAIH52 High Level Analog Input/STI
MU-TAIH53 High Level Analog Input
MU-TAIH62 Enhanced Power High Level Analog Input/STI
MU-TSTX03 Smart Transmitter Interface (Single IOP)
MU-TSTX13 Smart Transmitter Interface
MU-TSTX53 Smart Transmitter Interface
MU-TAIL02 Low Level Analog Input (Single IOP)
MU-TAIL03 Low Level Analog Input (Single IOP)
MU-TAMR02 Low Level Analog Input Multiplexer RTD (Single IOP)
MU-TAMR03 Low Level Analog Input Multiplexer RTD (Single IOP)
MU-TAMT02 Low Level Analog Input Multiplexer TC (Local CJR, Single IOP)
MU-TAMT03 Low Level Analog Input Multiplexer TC (Local CJR, Single IOP)
MU-TAMT12 Low Level Analog Input Multiplexer TC (Remote CJR, Single IOP)
MU-TAMT13 Low Level Analog Input Multiplexer TC (Remote CJR, Single IOP)

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000