Sales
Jim Pei
|
Email
[email protected]
|
Phone/Whatsapp
+86 18020776782
|
|
Model Number
|
3UF5001-3AB00-1
|
|
Control supply voltage
|
24 V DC
|
|
Adjustable current-dependent overload pickup
|
1.25–6.3 A
|
|
Main circuit voltage
|
110–690 V, rated operating voltage
|
|
Main circuit frequency
|
50-60 Hz
|
|
Main pole count
|
3
|
|
Control inputs
|
4
|
|
Control outputs
|
4
|
|
Auxiliary normally-open contacts
|
4 NO contacts
|
|
Switching behavior
|
Monostable
|
|
Communication interface
|
PROFIBUS DP
|
|
Physical bus interface
|
RS485
|
|
Maximum bus transmission rate
|
1.5 Mbit/s
|
|
Thermistor input
|
Provided
|
|
Current sensing arrangement
|
Straight-through current transformers
|
|
Auxiliary/control terminals
|
Screw terminals
|
|
Mounting
|
Screw or snap-on mounting
|
|
Protection rating
|
IP20
|
|
Operating temperature
|
-25 to +60 °C
|
|
Minimum Order Quantity
|
1 Piece
|
|
Price
|
Contact for Jim
|
|
Packaging Details
|
Original new Factory Sealed
|
|
Delivery Time
|
3–7 Days
|
|
Payment Terms
|
T/T
|
|
Shipping Method
|
DHL / FedEx / UPS / TNT
|
|
Supply Ability
|
In stock
|
Siemens 3UF5001-3AB00-1 is a SIMOCODE-DP basic unit for motor protection and control. The specified configuration uses a DC control supply. Integrated current sensing covers the stated adjustment range. A thermistor input supports connection of the corresponding motor temperature circuit. PROFIBUS DP provides the automation communication interface.
The basic unit combines motor feeder supervision with control integration. Its inputs and outputs connect the control arrangement to the motor feeder. Current sensing and the thermistor circuit serve different monitoring purposes. Review the installed contactor circuit and parameter settings before maintenance. Match the complete order number when replacing an existing SIMOCODE-DP unit.
3UF5001-3AB00-1 is used in motor control centers and motor feeder panels. It brings motor protection and control information into a PROFIBUS automation arrangement. The feeder circuit and protection settings must be engineered together.
For maintenance of installed SIMOCODE-DP equipment, 3UF5001-3AB00-1 is selected according to the original motor feeder design. Check the sensing path, temperature circuit and control terminals. Preserve the existing device parameters before replacement.
|
EC3-X33 PCN 807783
|
CES-A-UEA-04B
|
LR9502
|
|
S100-T
|
ATW-RC13
|
RFC-215
|
|
DVI-2325-FO
|
FX-PCX1711-0
|
SAVI 440 W440-M
|
|
nb1600
|
M3A-B2Lj2-SSP
|
SMT-CD-R20
|
|
600 L25
|
PGDT04000F020
|
inbio460
|
|
KFDO-HMS-16
|
7012AC 1423157-5
|
HL8102B
|
|
TF42-4.2 1SAZ721201R1035
|
MIL-RC3412 10/100BASE-TX
|
2002SS
|
|
XJBO3-5921-1
|
PT220-256L-DNET
|
XEV22D-1P2CO
|
|
HNWG50086423-006
|
X-3675-858-1
|
FX-PCG2621-0
|
|
5506-X
|
DPM-PGD3V 744745-003
|
EL6631-0010
|
|
2CDG110128R0011
|
PS4-101-DD1
|
F193
|
|
H2S 02000-A-1758
|
1381V PL-1381-11-V
|
HW100
|
|
110072003 20DI
|
AZURE-5020MM
|
SMC5500/S
|