Sales
Jim Pei
|
Email
[email protected]
|
Phone/Whatsapp
+86 18020776782
|
|
Model Number
|
6ES7158-3AD10-0XA0
|
|
Rated supply voltage
|
24 V DC
|
|
Permissible supply voltage
|
19.2-28.8 V DC
|
|
Power failure buffering
|
10 ms
|
|
Maximum inrush current
|
1.6 A
|
|
Inrush I²t
|
0.031 A²·s
|
|
Maximum right-side current
|
360 mA at 19.2 V, right-hand supply terminal, with 2 x BA 2xLC
|
|
Maximum left-side current
|
320 mA at 19.2 V, left-hand supply terminal, with 2 x BA 2xLC
|
|
Power loss
|
4 W at 24 V with 2 x BA 2xRJ45
|
|
Additional optical-interface power
|
750 mW per optical interface; 3 W with 2 x BA 2xLC
|
|
PROFINET interfaces
|
2, via BusAdapter
|
|
Ports per PROFINET interface
|
2
|
|
Transmission rate
|
100 Mbit/s, full duplex
|
|
Station input data
|
1440 bytes
|
|
Station output data
|
1440 bytes
|
|
Input addresses per module
|
254 bytes
|
|
Output addresses per module
|
253 bytes
|
|
Maximum submodules
|
116
|
|
Maximum data record length
|
4096 bytes
|
|
Data record FIFO depth
|
8
|
|
Coupling modules, non-isochronous
|
16
|
|
Coupling modules, isochronous
|
3
|
|
Isochronous cycle time
|
500 us
|
|
Shared-device controllers
|
4 per line side, non-isochronous mode
|
|
MRP ring size
|
Up to 50 devices
|
|
MRPD ring size
|
Up to 30 devices
|
|
Isolation type test
|
707 V DC
|
|
PROFINET network load class
|
3
|
|
PROFINET security class
|
1
|
|
Horizontal operating temperature, FS05 onward
|
-30 to +60 °C
|
|
Vertical operating temperature, FS05 onward
|
-30 to +50 °C
|
|
Engineering software
|
TIA Portal V20 or later; STEP 7 V5.7 SP3
|
|
GSDML version
|
V2.4.x
|
|
BusAdapter delivery
|
Not included
|
|
Maximum installation altitude
|
5000 m; restrictions apply above 2000 m
|
|
Minimum Order Quantity
|
1 Piece
|
|
Price
|
Contact for Jim
|
|
Packaging Details
|
Original new Factory Sealed
|
|
Delivery Time
|
3–7 Days
|
|
Payment Terms
|
T/T
|
|
Shipping Method
|
DHL / FedEx / UPS / TNT
|
|
Supply Ability
|
In stock
|
Siemens 6ES7158-3AD10-0XA0 is a SIMATIC PN/PN Coupler for exchanging data between PROFINET networks. The module uses separate PROFINET interfaces with interchangeable BusAdapters. It operates from an industrial DC supply. The coupler supports cyclic data exchange and data record transfer. BusAdapters are not included in the stated delivery configuration.
The PN/PN Coupler connects automation cells while keeping the associated controller projects separate. Shared-device arrangements allow defined access by multiple controllers. Network redundancy options support suitable PROFINET topologies. Engineering must match the installed firmware and function status. Select the BusAdapters and coupling configuration for the required network connection.
6ES7158-3AD10-0XA0 is used at boundaries between independently controlled production cells. The coupling arrangement exchanges process information without combining the controller projects. It suits coordinated machinery where each cell retains its own automation responsibility.
In segmented plant networks, 6ES7158-3AD10-0XA0 provides a defined interface for production and status data. Design the access relationships and redundancy arrangement together. Confirm the network media before selecting the BusAdapters.
|
7266A
|
MBUS01P.431
|
CV490 490-4AA00-0AA2
|
|
IS-DG102P-F-1
|
VLC-12CH-10A
|
6029493 PG320240WRT-MNN-IQ
|
|
KE 1051 A004-9
|
UE4740-22H0000
|
OAW-AP1201H-RW
|
|
CP-317/2000IOIF JACP-317901
|
TIOC-555 17-505555-001B
|
SXWUI16XX10001 SXWTBIOW110001
|
|
EL6692
|
PPM4-PN-MAINS-24
|
TF223AD/U
|
|
E244-16C-G-LS-D8-CR-SQ-BR
|
TXA207D
|
DT-7
|
|
D5014S
|
TM218LDA40DR4PHN
|
2cdg 110095 R0011
|
|
AC2458 M12 2DI-Y 2DO
|
HWIC-1GE-SFP
|
PCO5 PCO5000000AS0
|
|
MTN6730-0003
|
IN1608
|
VROM-160 SUM D59B
|
|
C445UM 3-4576-001A
|
325-A2A1A
|
TMSR-380-33-U-SB-TYS
|
|
700-CF220ZS
|
LBB4440/00
|
OD7685/OD7685.12
|
|
CS14PR-SX-24VDC
|
ADC8220/22
|
RT500
|
|
DMC-4K-HD
|
4GSTLS
|
R0f1314228/5
|