| SALES | PHONE / WHATSAPP | |
|---|---|---|
| Jim Pei | [email protected] | +86 18020776782 |
| Model Number | 6ES7461-0AA00-0AA0 |
| Product Family | SIMATIC S7-400 |
| Product Type | IM461-0 receiver interface module |
| Required Transmitter | IM460-0 |
| Coupling Type | Short-range expansion-rack coupling |
| Maximum Link Length | 3 m; 5 m from hardware revision A4 |
| Communication Bus | Transferred at full baud rate |
| Rack Number Range | 1 to 21 |
| External Backup Input | 5 to 15 V |
| Input Connector | X1 |
| Downstream / Terminator Connector | X2 |
| Internal Fault LED | INTF red |
| External Fault LED | EXTF red |
| Backplane Current | 260 mA typical; 290 mA maximum at 5 V DC |
| Power Loss | 1.30 W typical; 1.45 W maximum |
| Terminator | 6ES7461-0AA00-7AA0 |
| Dimensions | 25 x 290 x 280 mm |
| Weight | 610 g |
| PURCHASING TERM | DETAILS |
|---|---|
| Minimum Order Quantity | 1 Piece |
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3–7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
|
01
Accept the central-rack linkX1 receives the interface cable from the previous module.
|
02
Set the rack identityCoding switches assign the expansion-rack number.
|
|
03
Continue or terminateX2 connects the next rack or the required terminator.
|
04
Protect backed-up dataThe external supply input can maintain backup during rack-power work.
|
|
5 m
Maximum from revision A4
|
290 mA
Maximum 5 V current |
1-21
Rack address range |
| Near-rack expansionDesigned for short S7-400 expansion links. | Full bus rateThe communication bus is carried at full baud rate. | Revision-dependent distanceFive-metre operation requires the documented hardware revision. |
| 01 | Which sender works with 6ES7461-0AA00-0AA0? | Pair it with the S7-400 IM460-0. |
| 02 | When can 6ES7461-0AA00-0AA0 support a 5 m link? | The manual permits 5 m from hardware revision A4; earlier hardware is limited to 3 m. |
| 03 | What input can maintain backup on 6ES7461-0AA00-0AA0? | The external backup socket accepts 5 to 15 V. |
| 04 | Why must power be removed before changing the rack number on 6ES7461-0AA00-0AA0? | The manual requires de-energizing the expansion rack before altering the coding switches. |
| 05 | Which current is drawn by 6ES7461-0AA00-0AA0 from the backplane? | The value is 260 mA typical and 290 mA maximum at 5 V DC. |
| 06 | How is the final link closed after 6ES7461-0AA00-0AA0? | Install the specified 6ES7461-0AA00-7AA0 terminator at X2. |
| AKM115F120 | MN-S3-500 | MES1A |
| Few-K4A5VB | FS5850-12-05 | EDS-G308-T |
| X87-813 | DIO32-C | SIM-CNR04E |
| SMI472-12 | V28410A-1101100 | B501-IV |
| AEM-24AT | DDBC320-DALI | PRG2000RW |
| MAUX2 | K100MPWM0000 | DR4208SGM |
| STP100-200 | XEV22D-1P2CO | CLAXEH00ND100A |
| IZM-SEC-TB15 | M2150-4DBC | NR500-S3G |
| C-9402 | DM01D01ACC | DN520 |
| MMC-120A-F000 | RC87618222 | WLP150H |
| ECC-301 | VLM-000-SIE | DE4161-001 |
| PCX924 | M2150-2DBC | PGD1RH0F00 |
| DPG1K | PCO5000000AS0 | ECY-S1000 |