Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000
siemens 6es7634 2bf02 0ae3 simatic c7 634 dp compact control system-0

SIMATIC S7 Series

Home >  Products >  SIEMENS >  SIMATIC S7 Series

Siemens 6ES7634-2BF02-0AE3 SIMATIC C7-634 DP Compact Control System

Product Name: SIMATIC C7-634 DP Compact Control System
Brand Name: Siemens
Model Number: 6ES7634-2BF02-0AE3
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
Appurtenance:
  • Overview
  • Description
  • System Fit
  • Specifications
  • Migration Planning
  • Commercial Term
  • Contact info
  • FAQ
  • Other Products
  • Recommended Products
Legacy SIMATIC C7 compact unit combining an S7-300 CPU 315-2 DP with an OP17 operator panel
The C7-634 DP integrates PLC control and local HMI functions in one panel-mounted unit. Siemens identifies this exact revision with CPU 315-2 DP hardware 6ES7315-2AF03-0AB0 and an OP17 front panel, so both the STEP 7 program and the HMI project must be preserved.
Exact-match review: Confirm the complete C7 article, CPU and OP17 revisions, MPI/PROFIBUS addresses, I/O wiring, panel cutout and both project archives. Treat a move to separate PLC and HMI hardware as an engineered migration, not a plug-in exchange.

Description

6ES7634-2BF02-0AE3 is the SIMATIC C7-634 DP compact control system. It combines a CPU 315-2 DP control section with an OP17 operator interface, making the installed PLC program, HMI configuration and fieldbus layout equally important during service.
Before removing 6ES7634-2BF02-0AE3, record the rack and I/O assignment, MPI and PROFIBUS addresses, connected panels or programming devices, power wiring and every front connector. Verify that the PLC and HMI backups can be opened before the outage begins.

System Fit

The controller, operator panel and field wiring must be evaluated as one installed system.
CPU identity
Match the exact C7 order number and the integrated CPU 315-2 DP revision before selecting a replacement.
HMI identity
Preserve the OP17 project, language files, alarm texts, key assignments and transfer method.
Field connections
Photograph and label the power, I/O, MPI and PROFIBUS connectors before disconnection.

Specifications

Product type designation SIMATIC C7-634 DP
Order number 6ES7634-2BF02-0AE3
Integrated controller CPU 315-2 DP, hardware reference 6ES7315-2AF03-0AB0
Integrated HMI SIMATIC OP17 operator panel
Control platform SIMATIC S7-300 / C7 compact system
Fieldbus role PROFIBUS DP capable
Engineering reference STEP 7 project plus OP17 HMI project
Lifecycle note Legacy product; exact revision and project recovery required

Migration Planning

A controlled migration separates program recovery, communication conversion and panel mechanics.
Software archive
Validate both the STEP 7 PLC project and the operator-panel project on the intended engineering station.
Network record
Save MPI and PROFIBUS addresses, baud rates, termination positions and the complete DP slave list.
Acceptance test
Verify safe I/O, alarms, recipes, operator keys and every DP station before returning the machine to service.

Commercial Term

uQuotation
Current price and availability
Payment
T/T or agreed terms
Lead time
Confirmed with quotation
Shipping
DHL, FedEx, UPS or agreed freight
Warranty
12 months

Contact info

FAQ

Q1
How can I verify that 6ES7634-2BF02-0AE3 matches the installed C7 unit?
Compare the full order number and all revision labels, then confirm the integrated CPU 315-2 DP and OP17 configuration. Also record the panel cutout, front connectors, I/O assignment and MPI/PROFIBUS network before ordering.
Q2
What software backups are required before replacing 6ES7634-2BF02-0AE3?
Preserve the editable STEP 7 PLC project and the OP17 HMI project, including symbols, alarms, recipes, passwords and transfer settings. Test that both archives open correctly; an upload from the device may not recreate all original engineering data.
Q3
How should PROFIBUS compatibility be checked for 6ES7634-2BF02-0AE3?
Document the master configuration, station address, baud rate, DP slave list, GSD files, connector orientation and termination at both ends of each segment. Restore the same topology before changing any timing or diagnostic settings.
Q4
What should be inspected when 6ES7634-2BF02-0AE3 powers up but the OP17 does not show process values?
Check the controller operating state, HMI-to-PLC connection parameters, MPI/PROFIBUS cable and termination, configured addresses and the downloaded OP17 project. Read the CPU diagnostic buffer before replacing the integrated unit.
Q5
Can 6ES7634-2BF02-0AE3 be replaced by a separate S7 PLC and modern HMI?
Yes only through an engineered migration. The PLC program, HMI project, I/O wiring, fieldbus behavior, panel mechanics, operator keys and acceptance tests must be converted and validated together; there is no automatic drop-in equivalence.
Q6
What commissioning sequence is safest for 6ES7634-2BF02-0AE3?
Verify power and protective grounding, restore the approved PLC and HMI projects, confirm communications with outputs inhibited, test inputs and diagnostics, then release outputs and operator commands under the machine safety procedure.

Other Products

VAZ-2FK-G10-BRIDGE VAS/100.30 01-17981-00 011798100
EHS-220 ITRR832-001 05512123001 & 06241042001
DDI 24-12 TSP70 CS8550i-01
3RT1035-1AK64 DPS-750XB CHV-TSTATEX-FCU-W-T
EC3-X32 80PK-27 HWS600-48
H3-5068X03 SRD-91 HHC12WM
HWS600-24 ECY-S1000 Mini8
BS&B 2003 02-70325-02 L002IM310300673416
CT45XP CT45P-X0N-37D100G MPH-AC001A K910B
TK561.F.360.11/30.S.K5.10.S10.LD2-1130 SIGYOK-AIO16R-R SIGYOK-AIO16R-L

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000