Supply
24 V DC (20.4 to 28.8 V)
|
Network
PROFIBUS DP / MPI, up to 12 Mbit/s
|
|
Connection
Screw terminal blocks
|
Protection
IP20
|
|
Lead Time
In stock
|
Warranty
1 year
|
Rated supply
24 V DC
|
Typical current
30 mA
|
Transmission rate
9.6 kbit/s to 12 Mbit/s
|
Housing size
60 × 70 × 43 mm
|
|
Complete model
|
6ES7972-0DA00-0AA0
|
|
Brand
|
Siemens
|
|
Product family
|
Active RS 485 terminating element
|
|
Product type
|
SIMATIC DP RS485 terminating resistor
|
|
Application
|
Termination of PROFIBUS and MPI networks
|
|
Rated supply voltage
|
24 V DC
|
|
Permissible supply range
|
20.4 to 28.8 V DC
|
|
Current consumption
|
30 mA typical
|
|
Power loss
|
0.72 W maximum
|
|
Interface
|
PROFIBUS DP
|
|
Transmission rate
|
9.6 kbit/s to 12 Mbit/s
|
|
Supply connection
|
Screw terminal block
|
|
PROFIBUS cable connection
|
Screw terminal block
|
|
Protection rating
|
IP20
|
|
Operating temperature
|
0 to 60 °C
|
|
Storage / transport temperature
|
-40 to 70 °C
|
|
Relative humidity
|
95% maximum at +25 °C
|
|
Dimensions (W × H × D)
|
60 × 70 × 43 mm
|
|
Weight
|
Approx. 95 g
|
|
PROFIBUS DP
Provides active termination for RS485 bus segments operating from 9.6 kbit/s to 12 Mbit/s.
|
MPI networks
Supports termination of Siemens MPI network segments using the same active RS485 principle.
|
|
Maintenance continuity
Independent supply separates the termination function from the power state of bus stations.
|
Panel integration
Compact 60 × 70 × 43 mm enclosure with screw terminals for field wiring.
|
|
Power input
|
Apply 24 V DC within the permitted 20.4 to 28.8 V range.
|
|
Current demand
|
Allow for 30 mA typical current consumption.
|
|
Thermal load
|
Maximum published power loss is 0.72 W.
|
|
Bus performance
|
The PROFIBUS DP interface supports 9.6 kbit/s through 12 Mbit/s.
|
|
Termination purpose
|
Use at the end of a PROFIBUS or MPI segment that requires an active RS485 termination.
|
|
Mechanical envelope
|
Allow at least 60 mm width, 70 mm height and 43 mm depth for the device body.
|
|
Supply wiring
|
Use the dedicated screw terminal block and keep the applied DC voltage within 20.4 to 28.8 V.
|
|
Bus wiring
|
Terminate the PROFIBUS cable on the specified screw terminal block.
|
|
Location
|
Install in an environment compatible with IP20 protection.
|
|
Commissioning check
|
Verify supply polarity, secure terminal clamping and correct placement at the end of the intended bus segment.
|
|
Operation
0 to 60 °C
|
Storage / transport
-40 to 70 °C
|
|
Relative humidity
Up to 95% at +25 °C
|
Degree of protection
IP20
|
|
Recommend model
|
||
|
M8024-10GBASE-T
|
b-3P
|
PMA 9407 489 60001 KS800-CAN
|
|
DX3 406295
|
NX-148E
|
RS-485 101-0020
|
|
972LX IS23DI0XCD000
|
BMXNOE0100
|
CPM500
|
|
CX1010-0011 CX1010-N030
|
GE CL45D300M 295168
|
1550/PM 473004
|
|
100-E116 /A
|
3HE04324AAAA02 IP9IACPEAA
|
A456CFNFBS
|
|
OPT-B8-V:3Pt100 181B0305
|
MZ-N710
|
EP1502 103830 REV:1.22.9
|
|
TS3624N23E5
|
0902073100 GI357.Z80
|
MTN647395
|
|
1747-L542
|
Mipro ACT-311B
|
WT260-P560
|
|
UDK-04-10 (KNX) 215.0030.00
|
MC250-4T/1FS
|
Grant 1025
|
|
MSE-C20
|
FC-TSAOH-0220M
|
88974041 M3 CD12- 8I/4O
|
|
2CDG110079R0011
|
ABB 0768458
|
AG8/WB
|
|
ADV551-PF0
|
116-010038A GK60-2
|
ARD-CPU-RM A1110014
|
|
DDRC810
|
L4E 638-662
|
ESP415D1
|
|
T266-DC-15
|
MC3100-RL3S04E00
|
ELPLM04 V12H004M04
|
|
TA410
|
CT-253 5-240Aac
|
Brady 76611
|
|
ABB 6122/01-84-500
|
ABB FC/S1.1 2CDG120001R001
|
25/50-0,5-A04
|
|
9977 cDAQ / cRIO
|
Xt2001 MK03260-02
|
MNL-13RF3 MNL-13R
|
|
S4-710
|
Nucps-hk / 1b
|
4116 PR 4501
|
|
C-Bus2 L5508RVFP
|
HW100
|
6GK5208-0BA00-2AB2 XB208
|
|
AMPS-24E
|
POL688.10 / STD S55396-C881-A100
|
MTN565291
|