Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000
siemens 6gk1562 3aa00 simatic net cp 5623 profibus processor-0

SIEMENS

Home >  Products >  SIEMENS

Siemens 6GK1562-3AA00 SIMATIC NET CP 5623 PROFIBUS Processor

Product Name: SIMATIC NET CP 5623 PCI Express PROFIBUS Processor
Brand Name: Siemens
Model Number: 6GK1562-3AA00
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
Appurtenance:
  • Overview
  • PROFIBUS Services
  • Description
  • Specifications
  • PC Configuration
  • Commercial Term
  • Contact info
  • FAQ
  • Other Products
  • Recommended Products
PCI Express x1 communications processor for PROFIBUS DP master, DP device, FDL, PG and S7 services
The CP 5623 connects a PC station to PROFIBUS through a 9-pin RS485 interface at 9.6 kbit/s to 12 Mbit/s. Siemens includes the configuration tool and DP-Base software, while FMS and S7 services require the appropriate SIMATIC NET software packages.
PC-station recovery mapVerify the PC has a compatible PCI Express x1 slot and supported operating system, then preserve the PC-station configuration, PROFIBUS address, baud rate, master or device role, GSD data and application driver dependencies.

PROFIBUS Services

Map the software service and bus role before restoring the CP in a PC station.
DP role
Record whether the board is a DP master or DP device and preserve every slave address, module and diagnostic assignment.
Software stack
Identify DP-Base, FDL, FMS-5613 or HARDNET-PB S7 use and retain the corresponding license and project files.
Physical segment
Document the RS485 cable, connector, shielding, station address, baud rate and termination position.

Description

6GK1562-3AA00 is a half-length PCI Express x1 board for PC-based PROFIBUS communication. It supports DPV0, DPV1 and DPV2 as a DP master and DPV0 or DPV1 as a DP device, with port diagnostics available.
Replacing the board successfully requires more than moving the RS485 connector. The approved SIMATIC NET software, licenses, PC-station configuration and application interfaces must match the restored Windows environment.

Specifications

Product type designation SIMATIC NET CP 5623
Order number 6GK1562-3AA00
Host interface PCI Express x1, half length
PROFIBUS interface 9-pin Sub-D, RS485
Transfer rate 9.6 kbit/s to 12 Mbit/s
DP services DPV0, DPV1 and DPV2 master; DPV0 and DPV1 device
DP devices as master Up to 124
Open communication FDL driver included; up to 80 connections
S7 communication Requires HARDNET-PB S7; up to 50 connections
Operating temperature 5 to 60 degrees C
Power loss 5.4 W
Dimensions / weight 18 x 112 x 168 mm; approx. 102 g

PC Configuration

Hardware detection, SIMATIC NET configuration and application access must all be restored in the same tested sequence.
Platform check
Confirm a supported operating system and a suitable PCI Express x1 slot before removing the installed board.
Station project
Back up the SIMATIC PC-station project, communication connections and application interface settings.
Commissioning
Verify board detection and port diagnostics first, then bring the PROFIBUS segment online and test each required service.

Commercial Term

Quotation
Current price and availability
Payment
T/T or agreed terms
Lead time
Confirmed with quotation
Shipping
DHL, FedEx, UPS or agreed freight
Warranty
12 months

Contact info

FAQ

Q1
Can 6GK1562-3AA00 be moved into a newer PC without changing the PROFIBUS application?
Only after confirming the operating system, PCI Express slot and installed SIMATIC NET software support the CP 5623. Restore the PC-station configuration and licenses, then validate the application interface before reconnecting the production bus.
Q2
Why can Windows detect 6GK1562-3AA00 while the PROFIBUS network still remains offline?
Device detection proves only the PCI Express path. Check the SIMATIC NET driver, configured PC-station slot, CP operating state, station address, baud rate, RS485 connector, shielding and segment termination.
Q3
What should I back up before replacing 6GK1562-3AA00 in a PC station?
Save the SIMATIC PC-station configuration, DP master or device project, GSD files, connection definitions, application configuration and license information. Record the physical slot, PROFIBUS address, baud rate and normal port-diagnostic state.
Q4
How should I diagnose intermittent DP-device loss on 6GK1562-3AA00?
Use port diagnostics and the DP master diagnostics to identify the first missing station, then inspect connector seating, shielding, termination and baud-rate-related cable limits. Avoid changing the project until the physical segment has been verified.
Q5
Can the successor CP be substituted for 6GK1562-3AA00 without an engineering review?
No. A successor can require different driver, operating-system, license or hardware-catalog support. Compare the PC platform, software release, application API and validated PROFIBUS configuration before approving a migration.
Q6
What commissioning order is recommended after installing 6GK1562-3AA00?
Confirm BIOS and operating-system detection, install the approved SIMATIC NET software, restore the PC-station project, verify the CP mode and port diagnostics, and only then connect the PROFIBUS segment and test DP, FDL or S7 services one by one.

Other Products

400-NCMP2B.88
LIP-ME201 100Base-T
3007A
1073922V3
9448.808
6ES5460-4UA13
fc-tsdi-1624c
MA1479A
MP2O3HCGL
GE D20
DCJ4501-01PLF PSU-350-AC
Ref.04813
QAA25
1AK23148AAAA
CS60 39159-02
RIA141X-DA
MB-6279
R0f1314228/5
UGC8000
ABB DA501 1SAP250700R0001
T02-3101-000
SPB-00154
DR4208SGM
59212-00
Epxpns101-Abac
225629-007
RS-1140-0000
60-690-02 MTP RL 15HD
QBE63-DP01
CEN-IDOCV-W

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000