Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000
siemens 6se7090 0xx84 0ah2 simovert masterdrives t300 module-0

SIEMENS

Home >  Products >  SIEMENS

Siemens 6SE7090-0XX84-0AH2 SIMOVERT MASTERDRIVES T300 Module

Product Name: SIMOVERT MASTERDRIVES T300 Module
Brand Name: Siemens
Model Number: 6SE7090-0XX84-0AH2
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
Appurtenance:
  • Overview
  • Compatibility
  • Description
  • Service Checks
  • Specifications
  • Commercial Term
  • Contact info
  • FAQ
  • Other Products
  • Recommended Products
Legacy T300 technology module for application-specific SIMOVERT MASTERDRIVES functions
Siemens identifies 6SE7090-0XX84-0AH2 as a spare T300 module for the discontinued SIMOVERT MASTERDRIVES platform. Its suitability depends on the installed drive family, T300 application software, board revision, connector arrangement and saved machine configuration.
Before you orderMatch the complete article and board revision, drive type, T300 software or EPROM state, parameter backup, connector map and installed accessories before purchase; do not substitute the T300 retrofit kit article without checking scope.

Compatibility

A visual match is not enough for a legacy T300 exchange; the drive, application and delivery scope must agree.
Board identity
Photograph the complete article number, board revision, option labels and installed memory or application devices before removal.
Application state
Save the drive and T300 parameter data and identify the machine-specific technology application and software version.
Accessory scope
Check whether SC58 and SC60 leads and the SE300 terminal block remain serviceable or must be included in the replacement plan.

Description

6SE7090-0XX84-0AH2 belongs to the SIMOVERT MASTERDRIVES T300 technology-board system. Siemens lists the exact article as a discontinued spare part, so procurement and commissioning should be based on the installed nameplate and archived machine documentation.
The official SIMOREG documentation separately lists a T300 package with two connecting leads, SC58 and SC60, a terminal block SE300 and hardware instructions. Confirm which accessories are already installed because a board-only replacement and a complete package are not the same delivery scope.

Service Checks

Use a controlled electrical and functional sequence so a configuration or connector fault is not mistaken for a bad replacement board.
Safe isolation
Follow the MASTERDRIVES shutdown procedure, verify the DC link is discharged and use ESD controls before touching the module.
Connector map
Label every connector and terminal, inspect pins and cable strain, and reinstall each lead in the documented position.
Acceptance test
Restore the approved data, review diagnostics and test the technology function at a safe operating point before production release.

Specifications

Product type designation SIMOVERT MASTERDRIVES T300 module
Order number 6SE7090-0XX84-0AH2
Product role Application-specific technology module
Drive platform SIMOVERT MASTERDRIVES
Lifecycle status Discontinued spare part
Replacement listing No direct Siemens replacement listed
Published net weight 1.00 kg
Related T300 package leads SC58 and SC60
Related terminal block SE300
Configuration requirement Installed T300 application and parameters
Verification basis Full article, revision and drive documentation
Commissioning method Controlled backup, restore and functional test

Commercial Term

Quotation
Current price and availability
Payment
T/T or agreed terms
Lead time
Confirmed with quotation
Shipping
DHL, FedEx, UPS or agreed freight
Warranty
12 months

Contact info

FAQ

Q1
Can 6SE7090-0XX84-0AH2 be selected as a direct replacement only because the installed option board is marked T300?
No. Verify the complete article number, memory-module label, board revision, host SIMOVERT MASTERDRIVES unit, option-slot configuration and machine-specific T300 application. A generic T300 board or a board carrying different application memory may fit mechanically but will not necessarily reproduce the original machine function.
Q2
What information should be backed up before removing 6SE7090-0XX84-0AH2 from an operating drive?
Save the complete drive parameter set and the T300 application or STRUC project when available. Record the memory-module or EPROM identification, application version, encoder settings, analog and digital I/O assignments, serial-interface settings, scaling values and terminal map. Photograph the board, memory module and every cable before disconnection because a basic drive backup may not contain all T300-specific data.
Q3
Why can the host drive become ready after 6SE7090-0XX84-0AH2 is installed while the T300-controlled machine function remains unavailable?
Confirm that the correct memory module and machine application are installed, that the board is recognized in option slot 2 and that every external T300 connection matches the original terminal documentation. Inspect the screened cables, connector orientation and SE300-side wiring where that terminal system is used. Test each required technology signal before modifying parameters or application software.
Q4
What should be checked if encoder or positioning feedback becomes unstable after installing 6SE7090-0XX84-0AH2?
Verify the encoder type, supply, pulse count, channel polarity, cable shielding, grounding and connector condition. Compare the T300 scaling, direction and limit settings with the archived application. Perform the first test at a controlled low-risk operating point and monitor the feedback signal before enabling the complete positioning or technology function.
Q5
How should 6SE7090-0XX84-0AH2 be removed or installed safely in a SIMOVERT MASTERDRIVES unit?
The work must be performed by qualified drive-service personnel. Isolate every power source, observe the specified DC-link discharge time, prove absence of voltage and apply ESD protection. Never insert or remove the board while voltage is present. Install the technology board only in the approved option slot and verify all connectors before the converter is energized.
Q6
Is 6SE7090-0XX84-0AH2 appropriate for a new machine design or modernization project?
It should normally be treated as an exact-match legacy spare, not as the default choice for a new design. Siemens classifies the product as phased out or discontinued, available only while stock remains with conditional repair, and not RoHS-compliant. Before using it in a modernization project, confirm the destination-market compliance requirements and obtain an engineered migration recommendation for the drive and its machine-specific T300 application.

Other Products

D5090S
004404-005 Q9001L2002
6FX5002-5CN01-1BA0
E100
A01FDLV
43T69451
SRM-96/ 40-053 00-61.6100.5115.58
50098843
L1485BOXE07
9006450000
CON 232
38B6041X022
NK105
AEA4D-05
XLS757-7A-T
PRO32R2
664-21681-000
GE IC200MDL940A
950225
PXR11
3500/20 125760-01
GE IC200MDD844F
MTL5541
XPIQ-MBPCA
LFI520 RIF-R
SCD2200-RTU P0924XV
RA92-00644A
ZB150-100
P50099086
ML350 801233-B21

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000