siemens 6sl3352 6tg37 4aa3 sinamics s replacement control interface board-0

SIEMENS

Home >  Products >  SIEMENS

Siemens 6SL3352-6TG37-4AA3 SINAMICS S Replacement Control Interface Board

Product Name: SINAMICS S Replacement Control Interface Board
Brand Name: Siemens
Model Number: 6SL3352-6TG37-4AA3
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
  • Overview
  • Drive Integration
  • Description
  • Service Safety
  • Specifications
  • Commercial Term
  • Contact info
  • FAQ
  • Other Products
  • Recommended Products
Spare control-interface board for a 500 to 690 V, 735 A SINAMICS motor module
Siemens identifies 6SL3352-6TG37-4AA3 as a replacement Control Interface Board for a 500 to 690 V three-phase, 50/60 Hz, 735 A SINAMICS S motor module. The product is discontinued without a listed replacement.
Drive-service checkMatch the converter family, motor-module order number, voltage and current class, board revision, connector layout, installed Control Unit and service documentation before ordering this spare board.

Drive Integration

The control board must be matched to the complete SINAMICS drive topology, not selected by current rating alone.
Host verification
Record the complete motor-module order number, voltage class, rated current, serial number and installed board revision.
Connector map
Label every ribbon cable, fiber or signal connector and protective-earth connection before removing the original board.
Control topology
Archive the Control Unit project, DRIVE-CLiQ topology, firmware and commissioning data associated with the power unit.

Description

6SL3352-6TG37-4AA3 is supplied as a spare Control Interface Board rather than as a complete motor module. A compatible exchange depends on the exact host power unit and the board revision used in that converter.
Before replacement, capture active alarms, drive topology, commissioning archives and nameplate data. High-energy drive work must follow the equipment manual, site isolation procedure and qualified-service requirements.

Service Safety

A board exchange inside a high-power converter requires both electrical isolation and controlled electrostatic handling.
Stored energy
Follow the official discharge waiting time, verify absence of voltage and apply the site lockout procedure before opening the power unit.
ESD protection
Use approved electrostatic-control measures and handle the replacement only by its permitted edges or service points.
Commissioning check
After installation, verify topology, firmware compatibility, fan and temperature status, then test at controlled load before release.

Specifications

Product type designation
Replacement Control Interface Board
Order number
6SL3352-6TG37-4AA3
Product family
SINAMICS S
Host equipment
Motor Module
Host voltage class
500 to 690 V three-phase AC
Host frequency
50/60 Hz
Host current class
735 A
Supply scope
Spare board, not a complete motor module
Lifecycle status
Discontinued without listed replacement
Net weight
0.4 kg

Commercial Term

Quotation
Current price and availability
Payment
T/T or agreed terms
Lead time
Confirmed with quotation
Shipping
DHL, FedEx, UPS or agreed freight
Warranty
12 months

Contact info

FAQ

Q1
How should I verify that 6SL3352-6TG37-4AA3 fits my SINAMICS motor module before purchase?
Match the full host motor-module order number, 500 to 690 V class, 735 A rating, board revision, connector layout, Control Unit, firmware and Siemens service documentation.
Q2
What should I archive before replacing 6SL3352-6TG37-4AA3?
Save the complete drive commissioning project, DRIVE-CLiQ topology, parameters, firmware versions, alarm history and nameplate photos. Label every internal connector before disassembly.
Q3
Why can a drive still report topology or communication faults after installing 6SL3352-6TG37-4AA3?
Check that every connector is fully seated in its original position, compare board and host revisions, restore the approved drive project and review the first active alarm before changing parameters.
Q4
What safety checks are required before working on 6SL3352-6TG37-4AA3?
Use qualified drive-service personnel, isolate all power sources, observe the specified discharge time, prove absence of voltage and apply ESD protection in accordance with the official equipment manual.
Q5
How should I recommission the drive after replacing 6SL3352-6TG37-4AA3?
Restore the verified commissioning data, confirm topology and firmware, check cooling and temperature feedback, clear only understood alarms, then perform controlled no-load and load tests under the site procedure.
Q6
Which information should I provide when requesting 6SL3352-6TG37-4AA3 as a discontinued spare?
Provide the complete order numbers for the board and motor module, serial numbers, voltage and current class, board revision, Control Unit, firmware, fault history and clear connector photos.

Other Products

OBi302 2200-49532-102
15B10730G1
VAZ-2FK-G10-BRIDGE
VAS/100.30
01-17981-00 011798100
EHS-220
ITRR832-001
05512123001 & 06241042001
DDI 24-12
TSP70
CS8550i-01
3RT1035-1AK64
DPS-750XB
CHV-TSTATEX-FCU-W-T
EC3-X32
80PK-27
HWS600-48
H3-5068X03
SRD-91
HHC12WM
HWS600-24
ECY-S1000
Mini8
BS&B 2003
02-70325-02
L002IM310300673416
CT45XP CT45P-X0N-37D100G
MPH-AC001A
K910B
TK561.F.360.11/30.S.K5.10.S10.LD2-1130

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000