2 a co standard relay output module original newsiemens simatic et 200sp 6es7132 6gd51 0ba0 rq 4x24 vuc 2 a co standard relay output module original new-0

SIEMENS

Home >  Products >  SIEMENS

Siemens SIMATIC ET 200SP 6ES7132-6GD51-0BA0 RQ 4x24 VUC/2 A CO Standard Relay Output Module | Original New

SIEMENS SIMATIC ET 200SP
6ES7132-6GD51-0BA0
RQ 4x24 VUC/2 A CO Standard relay output module
OUTPUTS: 4 floating relay changeover contacts
RATING: 24 V AC/DC, 2 A
BASEUNIT: Type A0
LEAD TIME: In stock   |   WARRANTY: 1 year
Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • Applications
  • Interfaces
  • Diagnostics
  • Installation
  • FAQ
  • Recommend Models
  • Recommended Products
SIEMENS SIMATIC ET 200SP
6ES7132-6GD51-0BA0
RQ 4x24 VUC/2 A CO Standard relay output module
Exact Configuration
This ET 200SP Standard relay output module provides four floating changeover contacts for 24 V AC or DC resistive loads. Each channel has a common, normally closed and normally open contact.
Primary Function
Four isolated relay changeover outputs switch resistive field loads at up to 2 A per channel.
System Integration
Fits ET 200SP BaseUnit type A0 with CC00 identification and supports substitute values plus module diagnostics.

Technical Data

OFFICIAL CONFIGURATION DATA
6ES7132-6GD51-0BA0
Complete model
6ES7132-6GD51-0BA0
Product family
SIMATIC ET 200SP
Product type
RQ 4x24 VUC/2 A CO Standard relay output module
Hardware status
FS02 or later
Digital outputs
4 relay changeover contacts
Contact arrangement
Common, normally closed and normally open per channel
Rated supply voltage
24 V DC; permissible range 19.2 ... 28.8 V
Current consumption
50 mA rated
Power loss
Typically 1.2 W
Rated switching voltage
24 V DC or 24 V AC
Switching current
2 A maximum; 1 mA minimum at 5 V DC
Switching frequency
Maximum 2 Hz with resistive load
BaseUnit
Type A0
Color code
CC00
Diagnostics
Supply voltage and module diagnostics
Operating temperature
-30 ... +60 deg C horizontal; -30 ... +50 deg C vertical
Protection rating
IP20 within ET 200SP system
Dimensions
15 x 73 x 58 mm (W x H x D)
Weight
Approximately 30 g

Applications

DEPLOYMENT PROFILE
Relay-isolated field switching
Resistive loads
Switch four 24 V AC or DC resistive loads through floating changeover contacts.
Signal adaptation
Use relay isolation where transistor outputs are unsuitable for the connected field circuit.
Control behavior
Configure substitute values and reaction to CPU STOP in the ET 200SP project.

Interfaces

RELAY INTERFACES
Changeover-contact architecture
Four channels
Each output provides common, normally closed and normally open terminals.
Contact rating
Rated switching voltage is 24 V AC/DC with up to 2 A continuous current per channel.
Cable length
Official limits are 1000 m shielded or 200 m unshielded.

Diagnostics

DIAGNOSTICS
Module and supply monitoring
Supply diagnostics
The module can report missing or insufficient L+ supply voltage.
Visual status
DIAG, channel-status and PWR LEDs support commissioning and maintenance.
Fault scope
The module does not provide wire-break or short-circuit diagnostics at the relay contacts.

Installation

INSTALLATION
BaseUnit wiring and thermal limits
BaseUnit
Install on ET 200SP BaseUnit type A0 and use the CC00 identification code.
Contact wiring
Wire common, NC and NO terminals according to the required fail-state behavior and load circuit.
Thermal conditions
Observe -30 ... +60 deg C horizontal and -30 ... +50 deg C vertical operating limits.

FAQ

PROCUREMENT AND ENGINEERING CHECKS
Six model-specific questions
Q1. How can a buyer confirm the quoted unit is exactly 6ES7132-6GD51-0BA0?
A1. Match the complete Siemens article number, RQ 4x24 VUC/2 A CO ST designation, BaseUnit A0 and CC00 code on the label, packaging and quotation.
Q2. How can New, Used or Refurbished condition be distinguished?
A2. Request current photos of sealed packaging, nameplate, relay terminal area and BaseUnit connector, plus lot or serial data and written disclosure of prior switching use or repair.
Q3. How should the supplier be verified?
A3. Confirm the legal company, address, payment beneficiary and automation supply record. The written offer must identify 6ES7132-6GD51-0BA0 and the exact condition.
Q4. Which specifications should engineers check before purchase?
A4. Confirm four changeover contacts, 24 V AC/DC switching, 2 A rating, A0 BaseUnit, 15 x 73 x 58 mm dimensions, approximately 30 g weight and the required fail-state behavior.
Q5. What physical evidence should be requested before payment?
A5. Ask for time-stamped images of the actual module, article number, terminal markings, connector edge, packaging and shipment-specific identifiers.
Q6. Can a transistor output or another relay suffix replace it?
A6. Not automatically. Contact topology, current rating, diagnostics, switching frequency and project configuration differ; the electrical design and ET 200SP hardware project must approve any substitute.

Recommend Models

RECOMMEND MODEL
DS14
5X00226G04
1C31113G05
HFZ25
SPIIT13
PR6423/00R-010
SE4017P0
MVP50
IMDSM04
KJ3221X1-BA3
NPM22
5X00500G0
5X00500G01/1X00691H01
KJ3208X1-BA2
110E-JFS4J-912DA/NF2
V18345-302712000ZZ
KJ3243X1-BB1
KJ2005X1-BA2
SPDSI22
3051S2CD2A
3051TA1A
EJA530E-JBS
1C311
TPS02
EJA110E-JHS5J
IMMFP12
LR560
SPDSI13/SPFEC12/SPAS
RBC410
EJA438E-JAS
1C31219G01/1C31223G01
SE4603T05
HSS03
1C31122G02/1C31125G2
5X00063G01
KL4503X1-CA1
1C311166G02/1C31169G02
OC6000e
369B1848G5007
CE4001S2T2B6
SPASO11
BRC400
SE4001S2T2B5
CE4100
OC6000
5X00481G04/5X00226G04
IIT13
PR6423/10R-111
KJ4001X1-CC1
VE4031S2T2B6
KJ2201X1-JA1
KJ4110X1-BA1
SPBRC410ABB
KJ3208X1-BK1
5X00717G01
SPBRC410
KC4011X1-BP1
KJ4006X1-BK1
KJ3008X1-BA1
PR9268/201-000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000