INPUT
480 VAC/CT |
CT SECONDARY
1 A or 5 A |
|
BASEUNIT
BU type U0 |
SIZE
20 × 73 × 58 mm |
|
LEAD TIME
In stock |
WARRANTY
1 year |
The SIEMENS 6ES7134-6PA00-0CU0 is an ET 200SP analog input module for electrical energy measurement and network analysis. It supports 1 A or 5 A current transformers, BU type U0, and TT, TN, or IT supply systems.
Multivariable measurement Measures voltage, current, energy, frequency, active and reactive power, power factor, and related electrical values. |
Power-quality analysis Provides line analysis including THD, harmonics, voltage dip, voltage swell, and Class S measurements. |
ET 200SP integration Designed for BU type U0 with channel and module diagnostics, cyclic and acyclic measured-value access. |
|
Complete model
|
6ES7134-6PA00-0CU0
|
|
Product family
|
SIMATIC ET 200SP
|
|
Product type
|
AI Energy Meter 480 VAC/CT HF
|
|
Usable BaseUnit
|
BU type U0; color code CC20
|
|
Current-transformer input
|
1 A or 5 A secondary
|
|
Supply voltage
|
24 V DC; permissible 19.2 to 28.8 V
|
|
Current consumption
|
12.5 mA rated; 17 mA maximum
|
|
Voltage measurement
|
Up to 300 V phase-neutral / 519 V line-line
|
|
Frequency range
|
45 to 65 Hz
|
|
Supported systems
|
TT, TN, IT
|
|
Dimensions (W × H × D)
|
20 × 73 × 58 mm
|
|
Weight
|
Approx. 45 g
|
|
Energy monitoring
Acquire active, reactive, and apparent power plus energy values from one-, two-, or three-phase networks. |
|
Power-quality analysis
Monitor harmonics, THD, frequency, voltage dips, voltage swells, and related Class S quantities. |
|
Current-transformer systems
Use with 1 A or 5 A current transformers; direct current measurement without a transformer is not supported. |
|
Automation integration
Make measured values available cyclically or acyclically for control, diagnostics, and energy-management tasks. |
|
Module format
|
ET 200SP analog input module for BU type U0.
|
|
Color identification
|
Module-specific color code CC20.
|
|
Voltage inputs
|
Supports voltage measurement with or without an external voltage transformer.
|
|
Current inputs
|
Designed for 1 A or 5 A current-transformer secondaries.
|
|
Power supply
|
24 V DC, permissible range 19.2 to 28.8 V.
|
|
Address area
|
256 input bytes and 20 output bytes.
|
|
Diagnostics
|
PWR, channel-status, Fn, and DIAG indication with diagnostic functions.
|
|
Cable length
|
Maximum 200 m for shielded or unshielded measuring cables.
|
|
Select the correct BaseUnit
Install the module with BU type U0 and the documented ET 200SP terminal assignment. |
|
Define the network connection
Configure the actual TT, TN, or IT system and the correct one-, two-, or three-phase measurement arrangement. |
|
Set transformer parameters
Enter the installed current-transformer ratio and voltage-transformer data where used. |
|
Observe measurement limits
Keep voltage, current, frequency, cable length, insulation, and installation-altitude conditions within official limits. |
|
Commission in engineering software
Use a supported STEP 7 or GSD configuration and verify cyclic values, diagnostics, and direction of energy flow. |
|
Confirm the full order code
The quotation, module label, and documentation should all show 6ES7134-6PA00-0CU0. |
|
Verify the CT secondary
Confirm that the installation uses 1 A or 5 A current-transformer secondaries; Rogowski coils are not supported. |
|
Check voltage conditions
Validate the actual line-to-neutral and line-to-line voltages against the module measurement limits. |
|
Confirm BaseUnit and engineering
Verify BU type U0, color code CC20, address requirements, and the supported STEP 7 or GSD version. |
|
Review lifecycle status
This article is listed as a spare part; evaluate the official successor separately before accepting any substitute. |
|
70100AEP0N
|
AB7702-B MB100
|
MX-OPT-F2.0-L65-L25
|
|
ST403-AG41-24V 3383102-01
|
1SAP250100R0001
|
AMS-8
|
|
CDi 2000
|
T-ASH-G2-200
|
AP9631
|
|
AT-UHD-EX-70-TX
|
UMM-250
|
EB0518
|
|
LC5296H
|
C-30-TCPUSE-D-AI6 30dB
|
HDL-MAC01.231
|
|
621-9933C
|
IC694MDL916-CA
|
ABB DA501 1SAP250700R0001
|
|
SDV144-S33/PRP
|
SA7-701008-2 2-000009V3
|
ECM-77BC
|
|
Wago 750-323
|
A004-9 FQ00.640
|
AM-530-EUR
|
|
MT52340DB LF 52345DB
|
XCSLE3737312
|
ECINT1-1 730-802 RS232 RS485
|
|
4DP7APX0D 311F
|
2CDG 120 044 R0011
|
GE CR104PLG92G
|
|
7NG4021-6AA33-1NA1
|
A53 RS-232 RS-422/485
|
Q6310074R0111
|
|
Pro-OX-100
|
7800IDA2Q-3G 3G/HD/SD-SDI
|
PCO2 PCO2003AL0
|
|
140331 REV:11
|
3SB5235-6HE10
|
MINI-PS-100-240AC/24DC/1.3
|
|
453564086631-2 HL-20
|
HLF490S 323095
|
GT5 E9733BA-01
|
|
TA80DU-63
|
32441-1A
|
EL1809
|
|
VBA-4E4A-G12-ZAL
|
ELM-02-00-A0
|
pan04.eu
|
|
AB7702-B MB100 9-28VDC
|
SIO12000
|
PCB00259-02
|
|
ABB 6220-0-0117 SU-F-1.0.1
|
CK80
|
GE IC693MDL753E
|
|
AM313830035
|
H7080B2103
|
SF50339
|
|
1SDA066434R1
|
LC-103X15-B7644
|
3RU2116-1AB0
|