Complete model
|
6GK7542-5DX10-0XE0
|
|
Product family
|
SIMATIC NET CM 1542-5
|
|
Product type
|
PROFIBUS communications module
|
|
System compatibility
|
SIMATIC S7-1500
|
|
PROFIBUS interface
|
1 electrical connection
|
|
Connector
|
9-pin Sub-D socket (RS485)
|
|
Transfer rate
|
9.6 kbit/s to 12 Mbit/s
|
|
Supply voltage
|
15 V DC from backplane bus; +/-3%
|
|
Current consumption
|
0.2 A typical at 15 V DC
|
|
Power loss
|
3 W
|
|
DP master capability
|
DPV1; up to 125 DP devices
|
|
DP master address space
|
8,192 bytes inputs and 8,192 bytes outputs total
|
|
DP device capability
|
DPV0 and DPV1; 240 bytes inputs and 240 bytes outputs
|
|
Open communication
|
30 SEND/RECEIVE connections; 240 bytes per connection
|
|
S7 communication
|
48 connections maximum, subject to system limit
|
|
Modules per CPU
|
Up to 8, depending on CPU type
|
|
Protection rating
|
IP20
|
|
Operating temperature
|
-30 to 60 deg C horizontal; -30 to 40 deg C vertical
|
|
Storage temperature
|
-40 to 70 deg C
|
|
Installation altitude
|
Up to 5,000 m; restrictions above 2,000 m
|
|
Dimensions
|
35 x 142 x 129 mm (W x H x D)
|
|
Weight
|
0.4 kg
|
|
Mounting
|
S7-1500 rail mounting
|
|
Engineering
|
STEP 7 Professional V18 (TIA Portal) or higher
|
|
Approvals
|
CE, UKCA, cULus, KC, RCM, RoHS, EAC, ATEX, IECEx, FM
|
|
DP master
DPV1 master operation supports up to 125 DP devices.
|
DP device
DPV0 and DPV1 device operation is supported.
|
|
Data record routing
Data record routing is available between the controller and PROFIBUS network.
|
Open communication
Up to 30 SEND/RECEIVE connections with 240 bytes per connection.
|
|
Bus interface
One PROFIBUS interface with a 9-pin Sub-D RS485 socket.
|
Master data
8,192 bytes input and 8,192 bytes output address space as DP master.
|
|
Power input
The module draws 15 V DC from the S7-1500 backplane bus at 0.2 A typical.
|
Transfer rate
Selectable PROFIBUS rates from 9.6 kbit/s to 12 Mbit/s.
|
|
Web diagnostics
Web-based diagnostics are available through the S7-1500 CPU.
|
I&M data
I&M0 and I&M1 identification information are supported.
|
|
Time synchronization
The module can pass time synchronization through the system.
|
Industrial approvals
CE, UKCA, cULus, KC, RCM, EAC, ATEX, IECEx, and FM approvals are listed.
|
|
Module dimensions
35 x 142 x 129 mm; net weight 0.4 kg.
|
Rail mounting
Designed for S7-1500 rail mounting in a single-width compact format.
|
|
Mounting orientation
-30 to 60 deg C horizontally and -30 to 40 deg C vertically.
|
Engineering requirement
Configure with STEP 7 Professional V18 or higher.
|
|
Q1. How can I verify that the quoted item is exactly 6GK7542-5DX10-0XE0?
Match the complete order number on the quotation, label, packaging, and invoice. Confirm CM 1542-5, one 9-pin PROFIBUS Sub-D interface, V18 engineering requirement, and 35 mm module width.
|
|
Q2. How can I distinguish a new CM 1542-5 from a used or refurbished unit?
Request current photos of the Siemens label, housing, Sub-D socket, rail latch, and packaging. Inspect for mounting marks, connector wear, scratches, replaced labels, or resealing, and obtain the condition in writing.
|
|
Q3. How should a buyer verify that the supplier is legitimate and reliable?
Confirm the legal company name, registration, address, business contacts, and bank beneficiary. Request SIMATIC NET transaction references and make sure every document identifies 6GK7542-5DX10-0XE0.
|
|
Q4. Which specifications should an engineer verify before purchasing?
Confirm S7-1500 compatibility, 9.6 kbit/s to 12 Mbit/s PROFIBUS rate, 125-device DP master limit, 8,192-byte master address areas, 15 V backplane supply, STEP 7 V18 requirement, and 35 x 142 x 129 mm dimensions.
|
|
Q5. What physical evidence should be requested before payment?
Request timestamped photos or video showing the full 6GK7542-5DX10-0XE0 label, housing, 9-pin Sub-D socket, rail latch, packaging, and supplied accessories.
|
|
Q6. Can another CM or CP 1542-5 suffix replace 6GK7542-5DX10-0XE0?
Not automatically. Related models can differ in DP device count, open communication, S7 connection capacity, operating temperature, approvals, and TIA Portal version. Engineering must validate the complete order number and network design.
|
|
360G2-CRT12C-SM-PT
|
MFD-TA17
|
DVC6200
|
|
SNB-5003P
|
PXC00.D
|
I350-T2 I350T2V2BLK
|
|
IP100H
|
5210003-00A REV.A4 CS-LOOP
|
CR10
|
|
LP3A04
|
F000193 40T96
|
FP2-8-24
|
|
HI6100405
|
MS-VMA1615-0
|
IHRT46B/4D
|
|
M/L-10
|
ALAV208T
|
ISP-4D-DC-TERM
|
|
ABB CI541-DP PLC 1SAP224100B0001
|
113dg
|
6ES7648-6CA05-0YX0
|
|
AC5360B.0Z
|
PXC36.1-ED
|
UA830USTV
|
|
ABB CEM05100 2CMA137121R1000
|
401:C
|
PRO3000
|
|
3500/42M 140734-02S
|
DJH-20AC-R
|
A5E03891574
|
|
HFRR01-PC8-V10
|
BMXDDI6402K
|
ABB 2CDG110133R0011
|
|
Allen Bradley 2711P-RN6
|
HTXRC12A2
|
6MF1213-1GA05-0AA0
|
|
CC-PDIL01
|
WVC210
|
H4D2F1X
|
|
193-TAB40
|
DB9
|
AP9613
|
|
6ES7221-1BF32-0XB0
|
DDRC820FR
|
3500/32M 149986-02NC
|
|
SC90 90AF021
|
EMG125-B24
|
CX2500-0070
|
|
MS-NIE3910-2 MS-3910-2
|
POL945.00
|
CX9001-1101 CX9000-N000 CX9000-N010
|
|
PGDT04000FS00
|
CR1-RJ
|
M71C-1000-595-BR
|
|
Bsap-2035 17000949F1
|
180LR 4811504
|
MX321-2 E000-23212
|
|
T-ASH-G2-200
|
051204-M
|
CW-ANT-O1-NS-00 CW9163
|