INTERFACE
RS422 / RS485
|
PROTOCOLS
Freeport, 3964R, USS, MODBUS RTU
|
|
DATA RATE
Up to 115.2 kbit/s
|
CONNECTOR
15-pin D-sub socket
|
|
LEAD TIME
In stock
|
WARRANTY
1 year
|
SERIAL INTERFACE
Electrically isolated RS422/RS485 connection.
|
PROTOCOL RANGE
Freeport, 3964(R), USS and MODBUS RTU master/slave.
|
LONG LINKS
Documented cable lengths up to 1200 m depending on transmission mode.
|
MODULE DIAGNOSTICS
RUN, ERROR, RxD and TxD status indication.
|
|
Complete model
|
6ES7541-1AB00-0AB0
|
|
Product family
|
SIMATIC S7-1500
|
|
Product type
|
CM PtP RS422/485 HF communication module
|
|
Serial interface
|
RS422 or RS485; electrically isolated
|
|
Connector
|
15-pin D-sub socket
|
|
Protocols
|
Freeport, 3964(R), USS, MODBUS RTU master and slave
|
|
Maximum transmission rate
|
115.2 kbit/s
|
|
Maximum cable length
|
Up to 1200 m depending on mode and rate
|
|
Engineering
|
STEP 7 TIA Portal V12; STEP 7 V5.5 SP2 with GSD
|
|
Dimensions
|
35 × 147 × 127 mm
|
|
Weight
|
Approx. 0.22 kg
|
|
Backplane current
|
43 mA
|
|
Power from backplane bus
|
0.65 W
|
|
Power loss
|
0.6 W typical
|
|
Input address space
|
8 bytes
|
|
Output address space
|
8 bytes
|
|
Status indication
|
RUN, ERROR, RxD and TxD LEDs
|
|
Operating temperature
|
0 to 60 °C horizontal; 0 to 40 °C vertical
|
|
LEGACY DEVICE INTEGRATION
Connect serial instruments, drives and controllers to an S7-1500 automation system.
|
MODBUS NETWORKS
Operate MODBUS RTU master or slave communication over RS422 or RS485.
|
|
FREEPORT TELEGRAMS
Implement user-defined serial telegram formats for proprietary field devices.
|
DRIVE COMMUNICATION
Use the USS protocol for supported drive communication tasks.
|
|
RS422 MODE
Supports full-duplex point-to-point communication with separate transmit and receive pairs.
|
RS485 MODE
Supports half-duplex communication and network topologies allowed by the documented standard.
|
|
15-PIN D-SUB
The front connector carries transmit, receive, functional ground and control signals.
|
CABLE SELECTION
Use shielded Siemens connecting cables and respect rate-dependent cable-length limits.
|
|
Mounting
Install the 35 mm wide module on the S7-1500 mounting rail beside the assigned CPU or interface module.
|
Connector wiring
Wire the 15-pin D-sub connector for the selected RS422 or RS485 operating mode.
|
|
Shielding
Use the documented shield connection and grounding arrangement to maintain EMC performance.
|
Configuration
Select the protocol, transmission rate, character frame and address data in the supported STEP 7 environment.
|
|
D504
|
DPS400
|
EM 3490
|
|
KNX /644692
|
803374.EX O2T TQ8QUAD
|
430211006 T-525W
|
|
DCL-PRO-SAWU-4-40-PE 87658184
|
RA100Z
|
3500/42M 140734-02
|
|
MBS-1250 063G1781 0-300
|
6700+ P6701,2110000
|
FX-15 LP-FX15D22-000C
|
|
ANB10D-410
|
CFQ-5251 JMA-5200Mk2
|
XEV01D XEV01D-5N0B0-001
|
|
JL325A
|
DPG1K
|
FTD110DBMicro
|
|
HC12X-HUDDLEVIEW-G
|
AR-B9012 RS-422/485
|
UT320-00
|
|
130B1404
|
6ES7 972-0BB12-0XA0
|
60Gv2
|
|
DDNP1501
|
LCR55A
|
CNXIO-16
|
|
CLTG38L01
|
STR2003DA
|
LG-003652
|
|
D-60A
|
DPS500
|
ABB JA/S 4.230.1 GH Q631 0072 R0111
|
|
59604 S10MD
|
ABB 1SDA000624R1
|
300E
|
|
DRC410F 550410
|
130B7485
|
ABB 1SVR450055R0000
|
|
2967060 PLC-RSC-24DC/21-21
|
HPE 779153-001 DL360
|
ABB GJR2237600R1 DT370A 9090/076
|
|
WTR1-P421S08
|
38B5786X052
|
DRT1-ID16
|
|
PANAMETRICS 061088-A
|
XY2CE2A296
|
EYS3 A341 B0025
|
|
CR9440J1B1
|
DT3020
|
VBL-4POE-LTE
|
|
1F83-71 2
|
VT9611D3100
|
VLC-1600-E
|
|
BZME1-A80-BT
|
7PCJD0195B CMN-2333
|
2076283 PCOUMI2DN0
|
|
Fluke-62MAX
|
7012PC
|
NC3FD-LX
|