Product Name:Safe dry digital output FTA for SIL3 applications
Brand Name:Honeywell
Model Number:FC-TSRO-0824 V1.1
Country of Origin: USA
Warranty: 12 Months
Whatsapp:+86 18159889985
Email:[email protected]
Brand Name: |
Honeywell |
Model Number: |
FC-TSRO-0824 V1.1 |
Country of Origin: |
USA |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
in stock |
Payment Terms: |
T/T |
|
Sales Manager: |
Stella |
|
Send an email: |
|
|
Contact in Whatsapp: |
|
Parameter |
Specification |
|
Product Model |
FC-TSRO-0824 V1.1 |
|
Product Type |
Safe Dry Digital Output FTA |
|
Safety Level |
SIL3 (IEC 61508 compliant) |
|
Output Channels |
8 Independent Relay Channels |
|
Relay Type |
Triple relay per channel |
|
Output Contact Type |
Potential-free (floating) |
|
Max Switching Voltage |
250 Vac / 250 Vdc |
|
Max Switching Current |
5 A (fused) |
|
Max Load Capacity |
1250 VA / 150 W |
|
Fuse Rating |
5 AT slow-acting |
|
Input Voltage |
24 Vdc nominal |
|
Operating Voltage Range |
Up to 36 Vdc |
|
Isolation (Coil to Contact) |
4000 Vac |
|
Isolation (Contact to Contact) |
1200 Vac |
|
Switching Frequency |
Up to 20 Hz |
|
Operating Temperature |
-5°C to +60°C |
|
Dimensions |
30x7x6.2cm |
|
Weight |
0.5kg |
|
Mounting |
DIN EN TS35 / TS32 Rail |
|
Termination |
Screw terminals (2.5 mm² max) |
TheFC-TSRO-0824 V1.1is a SIL3-certified safe dry digital output Field Termination Assembly designed for high-reliability industrial automation systems. It provides a secure interface between system interconnection cables such asSICC-0001/Lxand external field devices, enabling precise and safe relay-based output control in mission-critical applications.
TheFC-TSRO-0824 V1.1features eight fully isolated, potential-free relay output channels. Each channel is equipped with triple-redundant relays, fused NO contacts, and integrated LED status indicators for real-time diagnostics. The design supports independent wiring per channel, ensuring flexible integration and enhanced fault isolation in complex control architectures.
Compatible with Safety Manager output modules such asSDO-0824, theFC-TSRO-0824 V1.1supports a wide range of industrial loads, including AC and DC switching up to 250 Vac. It is widely deployed in safety instrumented systems requiring SIL3 compliance and robust output reliability.
Q1: What is the main function of the FC-TSRO-0824 V1.1?
A1: It provides SIL3-safe relay-based digital output control for industrial automation systems.
Q2: How many output channels does the FC-TSRO-0824 V1.1 support?
A2: It supports 8 independent relay output channels.
Q3: Can the FC-TSRO-0824 V1.1 switch AC and DC loads?
A3: Yes, it supports both AC and DC switching up to 250 V.
Q4: Is the FC-TSRO-0824 V1.1 suitable for safety systems?
A4: Yes, it is designed for SIL3 safety instrumented applications.
Q5: What type of wiring does the FC-TSRO-0824 V1.1 use?
A5: It uses independent screw terminal connections for each output channel.
| number | describe |
|---|---|
| TDOL-0724P | Line-monitored relay contact digital output (7 channels, 24Vdc) |
| TDOL-0724U | Line-monitored relay contact digital output (7 channels, 24Vdc, RUSIO) |
| TDOL-07120 | Line-monitored relay contact digital output (7 channels, 120Vac/120Vdc) |
| TSDO-0424 | Safe digital output FTA (24 Vdc, 4 channels) |
| TSDO-04UNI | Safe digital output FTA (24/48/110 Vdc, 4 channels) |
| TSDOL-0424C | Conformal-coated safe digital output FTA, current limited, loop monitored (24 Vdc, 4 channels) |
| TDO-1624 | Non-safe digital output FTA (24 Vdc, 16 channels) |
| TSRO-0824 | Safe dry digital output FTA for SIL3 applications (8 channels) |
| TRO-0824 | Non-safe dry digital output FTA (8 channels, NO/NC) |
| TRO-1024 | Non-safe dry digital output (relay contact) FTA (10 channels) |
| TSAO-0220m | Safe analog output FTA (0(4)-20 mA, 2 channels) |
| TSAOH-0220m | Safe analog output FTA with HART interface (0-20 mA, 2 channels) |
| TPSU-2430 | 24 Vdc to 30 Vdc / 1 A converter |
| TSPKUNI-1624 | Sub-D to Powered Knife terminals FTA (Universal, 16ch) |
| DCOM-232/485 | RS232/485 communication FTA |
| SDW-550 EC | 5 port HSE communication FTA / switch |
| MTL 24571 | Single channel ethernet surge protector |
| IOTA-R24 | Redundant IO Termination Assembly |
| IOTA-NR24 | Non-redundant IO Termination Assembly |