PROGRAM MEMORY
450 KB integrated |
DATA MEMORY
1.5 MB integrated |
|
LEAD TIME
In stock |
WARRANTY
1 year |
FAIL-SAFE Safety operation up to SIL 3 and PL e. |
PROFINET IRT Integrated two-port switch for real-time networking. |
FAST EXECUTION Typical bit-operation time of 40 ns. |
|
Complete model
|
6ES7513-1FL02-0AB0
|
|
Product family
|
SIMATIC S7-1500F
|
|
Product type
|
CPU 1513F-1 PN fail-safe CPU
|
|
Dimensions
|
35 × 147 × 129 mm
|
|
Weight
|
Approx. 405 g
|
|
Hardware status
|
FS03
|
|
Firmware version
|
V2.9
|
|
Supply voltage
|
24 V DC; permissible range 19.2 to 28.8 V DC
|
|
Current consumption
|
0.7 A rated; 0.95 A maximum
|
|
Power loss
|
5.7 W typical
|
|
Program work memory
|
450 KB integrated
|
|
Data work memory
|
1.5 MB integrated
|
|
Load memory
|
SIMATIC Memory Card required; up to 32 GB
|
|
Bit processing time
|
40 ns typical
|
|
Interface
|
PROFINET IRT with integrated two-port switch
|
|
Safety capability
|
Up to SIL 3 and PL e / Category 4
|
|
Operating temperature
|
-25 to 60 °C horizontal; -25 to 40 °C vertical
|
|
Installation altitude
|
Up to 5,000 m with restrictions above 2,000 m
|
|
SAFETY AUTOMATION
Run standard and safety programs together for machinery and plant sections requiring functional safety. |
MACHINE CONTROL
Use the mid-range performance class for sequence control, interlocks and coordinated production cells. |
|
PROFINET IRT
Integrate distributed I/O, drives and HMI devices through the two-port real-time Ethernet interface. |
ENGINEERING FIT
Configure the documented firmware with compatible STEP 7 Safety and TIA Portal engineering versions. |
|
X1 PROFINET
One PROFINET IRT interface with two integrated RJ45 ports and switch functionality. |
MEMORY CARD
One SIMATIC Memory Card slot; the card is required for operation and load memory. |
|
DISPLAY
Integrated display and control keys support commissioning, diagnostics and maintenance. |
BACKPLANE
Direct connection to the S7-1500 backplane bus for signal and technology modules. |
|
1 Power
Provide a regulated 24 V DC supply within the documented 19.2 to 28.8 V range. |
2 Memory
Insert a compatible SIMATIC Memory Card before commissioning because the CPU requires it. |
|
3 Network
Plan the two-port PROFINET IRT topology and verify device names, addresses and cycle settings. |
4 Safety project
Use compatible TIA Portal and STEP 7 Safety versions; validate the F-program and signatures before startup. |
|
MS-RACK5
|
4000SR DSP-LIA012 LIA013
|
640-4512C-Z
|
|
330103-00-04-10-02-05
|
HDL-M/FCU01.10.1
|
AUD50A100D 1636F
|
|
5WG1 523-1AB02
|
C2-COM2
|
SB-910
|
|
Merten reg-k 683832
|
NBS4 DBS1224B4W
|
FC-TSDO-0824
|
|
FF20-S33
|
2CDG110 064 R0011
|
MS-IOM4711-0
|
|
PM2100 METSEPM2120
|
XMLG025D21
|
MWR-SH11UN
|
|
cPCI-R3610T
|
DLC-SLAVE
|
UMG 103-CBM
|
|
EXFS-L300
|
773100
|
140ACO13000
|
|
F02379
|
lnl-xf2110dgf17
|
BEPM-OC
|
|
ABB 1MRK000508-BDr03
|
DIO32-C
|
ET-788
|
|
ABB 2CL0813041ABB
|
PXX-L11
|
IP-2G4A
|
|
ABB 1SDA038302R1
|
J110
|
8DI ITEM3-2000U008000
|
|
125-485-862 & 125-065-769
|
PCS090 PG090.205.B
|
AMX526
|
|
SXWAO8XXX10001
|
FC-TAOH-0220M
|
6ES7222-1BF32-0XB0
|
|
LMUC-100-2
|
AT575-75VSW-TNCF-000-05-12-NM
|
Honeywell D254.DIN.110.US
|
|
TR-MG/500cc
|
B501-IV
|
MQSE-4S1-D
|
|
OID254
|
D-67722,MX-SM-D51-PW
|
BTPDA-4
|
|
JBUS/MODBUS 66061
|
VM-114H
|
SM1.125-C04L-20-V-SS-3182
|
|
ABB AI531 1SAP250600R0001
|
ACU-485CNV-U
|
RM-LP55/RM-LP55U
|
|
LBB1856/00
|
TMC240
|
VS-5FDT-1
|