Complete model
|
6EP1334-3BA10-8AB0
|
|
Product family
|
SITOP PSU200M
|
|
Product type
|
Stabilized power supply with protective coating
|
|
Input system
|
1-phase or 2-phase AC
|
|
Rated input voltage
|
120 to 230 V AC or 230 to 500 V AC
|
|
Permissible input range
|
85 to 264 V AC or 176 to 550 V AC
|
|
Line frequency
|
47 to 63 Hz
|
|
Rated input current
|
4.4 A at 120 V; 2.4 A at 230 V; 1.1 A at 500 V
|
|
Inrush current
|
35 A maximum
|
|
Rated output voltage
|
24 V DC, isolated and regulated
|
|
Output adjustment range
|
24 to 28.8 V DC
|
|
Rated output current
|
10 A
|
|
Rated output power
|
240 W
|
|
Output tolerance
|
3% total; 0.1% control precision
|
|
Ripple / peak
|
50 mV maximum ripple; 200 mV maximum peak
|
|
Relay output
|
24 V OK, NO contact, 30 V DC/0.1 A
|
|
Efficiency
|
91%
|
|
Overload capability
|
12 A constant; 30 A for 25 ms; switchable characteristic
|
|
Protection
|
Short-circuit proof; output overvoltage protection below 35 V
|
|
Protection rating
|
IP20; protection class I
|
|
Operating temperature
|
-25 to +70 deg C
|
|
Storage / transport temperature
|
-40 to +85 deg C
|
|
Dimensions
|
70 x 125 x 121 mm (W x H x D)
|
|
Installation dimensions
|
70 x 225 mm including required clearance
|
|
Weight
|
0.8 kg
|
|
Mounting
|
35 mm DIN rail per EN 60715
|
|
Approvals
|
CE, cULus Listed, UKCA, EAC, RCM; ABS and DNV maritime approvals
|
|
Power-failure buffering
Minimum buffering time is 25 ms at 120/230 V and typical buffering time is 150 ms at 400 V.
|
Parallel operation
Up to two power supplies can be connected in parallel to increase capacity or support a redundant design.
|
|
Status signaling
A 24 V OK relay provides a normally open contact rated 30 V DC/0.1 A for output status monitoring.
|
Overload response
The selectable overload characteristic supports 12 A constant output or latching shutdown, plus 30 A for 25 ms.
|
|
Input terminals
Screw terminals accept 0.2 to 2.5 mm2 conductors for the AC input connection.
|
Output terminals
Two output terminal pairs accept 0.2 to 2.5 mm2 conductors for the regulated 24 V DC output.
|
|
Auxiliary contact
The 24 V OK signaling contact uses screw terminals for 0.14 to 1.5 mm2 conductors.
|
Input selection
A selector adapts the unit to the two rated AC ranges before commissioning.
|
|
Electrical separation
Input and output are galvanically isolated. The regulated output is SELV, ES1 and DVC As.
|
Circuit protection
The power supply is short-circuit proof and limits output overvoltage to less than 35 V.
|
|
Device protection
Protection class I and IP20 are specified. Leakage current is 3.5 mA maximum and 0.32 mA typical.
|
Compliance
The unit carries CE, cULus Listed, UKCA, EAC and RCM approvals, with ABS and DNV maritime approvals.
|
|
DIN rail mounting
Install on a 35 x 7.5 mm or 35 x 15 mm DIN rail in accordance with EN 60715.
|
Mechanical envelope
Overall dimensions are 70 x 125 x 121 mm. Installation width x mounting height is 70 x 225 mm.
|
|
Required clearance
Maintain 50 mm free space above and below the device; no side clearance is required.
|
Ambient conditions
Operation is specified from -25 to +70 deg C. Transport and storage are specified from -40 to +85 deg C.
|
|
1
|
How can a buyer verify that the quoted unit is exactly 6EP1334-3BA10-8AB0?
Require a clear nameplate image showing the complete order number 6EP1334-3BA10-8AB0. Confirm SITOP PSU200M, protective coating, 24 V DC/10 A output and the 1-/2-phase AC input ranges against the order data.
|
|
2
|
How can New, Used and Refurbished condition be distinguished for this power supply?
Ask for current photos of the housing, DIN-rail latch, screw terminals, selector, LEDs and label. A New unit should show no terminal marks, rail-latch wear, repaired seals or removed identification labels.
|
|
3
|
How can a purchaser assess whether the supplier is legitimate and reliable?
Verify the legal company identity, business address, bank beneficiary and traceable invoice details. Ask the supplier to identify the exact 6EP1334-3BA10-8AB0 unit and provide recent physical evidence before payment.
|
|
4
|
Which specifications should engineers check before purchasing 6EP1334-3BA10-8AB0?
Confirm the available AC network and input selector setting, regulated 24 to 28.8 V DC output, 10 A load, 70 x 125 x 121 mm envelope, 0.8 kg weight, 35 mm DIN rail mounting, IP20 protection and required 50 mm top/bottom clearance.
|
|
5
|
What physical evidence should be requested before payment?
Request timestamped photos or video showing the full nameplate, complete model, terminal blocks, selector, relay contact, coating condition and unopened packaging. The evidence should correspond to the same unit included in the quotation.
|
|
6
|
Can a similar SITOP PSU200M part number or suffix replace this model?
Not automatically. Similar units can differ in rated input range, output current, coating, approvals, terminals or mechanical details. Substitute only after the engineer confirms every required electrical, environmental and installation specification.
|
|
DES-12-G 3PK-6500T
|
181B0719 CAV150C47R
|
PR6 2925M1221
|
|
IOP301 181517
|
19A3716X022
|
XND-6080RP
|
|
LV429120 NSX100-250 3P3DMA100
|
TM3DM24RG
|
ES1018
|
|
FLEXY20100_00MA/S
|
D4I4
|
6GK5212-2BB00-2AA3
|
|
ABB 1SNA115930R1300
|
H3W1F1X
|
CCL1-3G
|
|
MS4604F1210 50085000-004
|
GE IC200ALG431F GE IC200CHS002D
|
SGDB-05VD
|
|
JL086A
|
ABB DI561 / 1TNE968902R2101
|
DO-2-1
|
|
ES-162P3-2
|
6ES7221-1BF32-0XB0
|
15B10854G1 / 15H50548
|
|
60-869-03
|
2079872
|
ABB TA5142-RS485 1SAP187300B0003
|
|
NT00 10A gL10A
|
POL945.00
|
MMS-A-350
|
|
EMAXFD-BWU
|
ABB 1SDA038302R1
|
HEX70B-RX
|
|
DDFCUC024
|
Z4 MK4
|
DI125
|
|
IC695ALG616-LF RX3I
|
Tx0D 3020 0JF737 4GF/2GR
|
TV300
|
|
FTD110DBMicro
|
aci1230
|
ABB 6197/52-101-500
|
|
QPA2002D
|
027901
|
40501460
|
|
GE 463/100 606218
|
305228-PR
|
BMXEHC0800
|
|
SJ-201 178-930-2D
|
D351 V1.1 XA
|
PH3310
|
|
GH-VBX
|
6160V
|
CX9000-A001
|
|
ARK 3382
|
EI162AC
|
Ex09115666
|
|
AP-101-11-2
|
9611/52+62
|
C7232B5820
|