Complete model
|
VE4001S2T1B1
|
|
Brand
|
Emerson
|
|
Product family
|
DeltaV M-series Traditional I/O
|
|
Product type
|
Discrete input card with standard I/O termination block
|
|
Number of channels
|
8
|
|
Input type
|
24 VDC, isolated
|
|
Isolation
|
Each channel optically isolated from the system and each other; factory tested to 1500 VDC
|
|
Detection level for On
|
Above 10 VDC
|
|
Detection level for Off
|
Below 5 VDC
|
|
Input impedance
|
5 mA at 24 V
|
|
LocalBus current
|
75 mA typical; 100 mA maximum at 12 VDC nominal
|
|
Field circuit power
|
None
|
|
I/O card keying
|
B2
|
|
Compatible terminal block
|
Standard I/O termination block; fused option available
|
|
Mass termination option
|
16-pin mass termination block
|
|
Dimensions
|
H 10.7 x W 4.1 x D 10.5 cm
|
|
Weight
|
Not separately published for VE4001S2T1B1 in the selected official document
|
|
Protection rating
|
IP20
|
|
Operating temperature
|
-40 to 70 deg C
|
|
Storage temperature
|
-40 to 85 deg C
|
|
Relative humidity
|
5 to 95% non-condensing
|
|
Certifications
|
CE, FM, CSA, ATEX, IECEx; marine certifications include IACS E10, ABS and DNV
|
|
Exact marking
|
VE4001S2T1B1
|
|
Official identity
|
8-channel isolated 24 VDC discrete input I/O interface
|
|
Evidence to match
|
Match the complete VE4001S2T1B1 marking, standard I/O termination block, 8-channel layout and B2 card keying.
|
|
System
For DeltaV M-series Traditional I/O with MQ, MX or PK controllers and M-series horizontal or VerticalPlus carriers. This 8-channel isolated DI card is listed in simplex format.
|
Key selection
8 channels | On above 10 VDC | Off below 5 VDC | Key B2
|
Source control
Use the current official Emerson data sheet and confirm the installed carrier, software and revision before substitution.
|
|
Keying
Pre-wire the standard terminal block as required, confirm B2 keying, and insert only the correct isolated 24 VDC DI card. Follow the applicable hazardous-area installation procedure.
|
Field wiring
Verify polarity, signal range, isolation and the exact terminal-block wiring before energizing.
|
Environment
Maintain the published -40 to 70 deg C operating range, IP20 protection and applicable hazardous-area procedures.
|
|
Identity
Require a clear current photo showing the complete VE4001S2T1B1 marking.
|
Engineering match
Require the full model label, 8-channel isolated DI identity, standard terminal block, B2 keying, connector condition and terminal photos before payment.
|
Condition evidence
Request label, housing, connector, terminal, keying, seal and packaging photos before payment.
|
|
Recommended Model
|
Recommended Model
|
Recommended Model
|
|---|---|---|
|
AFV10D
|
6ES7400-1TA11-0AA0
|
6ES7517-3FP00-0AB0
|
|
6ES7654-7HX00-0XA0
|
TB852
|
DC522
|
|
VE4005S2B5
|
DO840
|
6ES7531-7NF10-0AB0
|
|
CM576-PNIO
|
ANB11S
|
CC-PCNT02
|
|
ARS15M
|
6ES7288-7ST40-0AA0
|
6ES7521-7EH00-0AB0
|
|
6ES7654-7HB00-0XA0
|
6ES7288-1CR40-0AA0
|
TU847
|
|
6ES7214-1BG40-0XB0
|
KJ3002X1-BF1
|
6ES7288-3AR04-0AA0
|
|
6ES7288-5DQ01-0AA0
|
6ES7288-5BA01-0AA0
|
1756-L74
|
|
TU835
|
6ES7217-1AG40-0XB0
|
ADV569
|
|
1756-OA16
|
6ES7231-5ND32-0XB0
|
6ES7332-5HF00-0AB0
|
|
AO810V2
|
ADV159
|
PM851K01
|
|
KS1
|
CI871K01
|
1756-DNB
|
|
6ES7518-4FP00-0AB0
|
6ES7392-1AM00-0AA0
|
6ES7518-4FX00-1AC0
|
|
ADV169
|
KJ1501X1-BC2
|
6ED1052-1HB08-0BA2
|
|
KJ2005X1-MQ1
|
ATK4A
|
1769-L18ER-BB1B
|
|
TU842
|
CI858K01
|
TP831
|
|
6ES7288-2DR32-0AA0
|
6ES7516-3FN02-0AB0
|
1769-L27ERM-QBFC1B
|
|
TU811V1
|
6ES7515-2FM02-0AB0
|
6ES7517-3AP00-0AB0
|
|
ADV151
|
6ES7522-1FH00-0AA0
|
6ES7231-4HF32-0XB0
|
|
KJ2005X1-BA1
|
6ES7332-5RD00-0AB0
|
TU515
|