Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000
vibro meter cp232 143 232 000 222 cp232 sensors with an integral mi cable original new-0

OTHER

Home >  Products >  OTHER

Vibro-meter CP232 143-232-000-222 CP232 sensors with an integral MI cable Original new

Product Name:CP232 sensors

Brand Name:Vibro-meter

Model Number:CP232 143-232-000-222

Country of Origin:Switzerland

Warranty:12 Months

Whatsapp+86 18159889985

Email[email protected]

Appurtenance:
  • Overview
  • Contact for quotation
  • Specifications
  • Description
  • Applications
  • Features
  • Functions
  • FAQ
  • Spares
  • Recommended Products

Overview

Brand Name:

Vibro-meter

Model Number:

CP232 143-232-000-222

Country of Origin:

Switzerland

Packaging Details:

Original new Factory Sealed

Delivery Time:

in stock

Payment Terms:

T/T

Contact for quotation

Sales Manager:

Stella

Send an email:

[email protected]

Contact in Whatsapp:

+86 18159889985

Specifications

Item Description
Model CP232 143-232-000-222
Product Type Piezoelectric pressure sensor
Series Vibro-Meter® CPxxx
Output Signal Charge output
Compatible System IPC707 signal conditioner
Sensitivity High-sensitivity piezoelectric sensing
Frequency Range 2 Hz – 10 kHz
Operating Temperature -55°C to +520°C
Cable Type Integral mineral-insulated (MI) cable
Max Cable Length ≤ 0.3 m (recommended for compatibility)
Static Pressure Range Up to 20 bar
Linearity ≤ ±1%
Dimension Ø18 mm × 60 mm (approx.)
Weight 50 g (sensor head) + cable weight
Housing Material High-temperature stainless alloy

Description

The CP232 143-232-000-222 is a high-precision piezoelectric pressure sensor designed for industrial vibration and dynamic pressure monitoring systems. As part of the Vibro-Meter® CPxxx series, the CP232 is engineered to deliver stable signal output and reliable performance in demanding environments such as turbines and heavy industrial machinery.

The CP232 143-232-000-222 is optimized for use with compatible IPC707 signal conditioning systems, enabling accurate signal transmission across the full measurement chain. Its design supports integration with piezoelectric sensing technology while maintaining consistent electrical characteristics for dependable operation in automation and diagnostic applications.

Due to its mineral-insulated cable configuration and electrical compatibility requirements, the CP232 143-232-000-222 is typically applied in short-cable measurement setups, ensuring optimal diagnostic performance and minimizing signal distortion in critical industrial monitoring environments.

Applications

Power plants: Used for generator set status monitoring and relay protection.
Substations: Enable bus differential control, line protection, and switchyard signal acquisition.
Chemical plants: Integrate process control automation and intrinsically safe signal monitoring.
Steel mills (metallurgical plants): Perform equipment logic control in harsh environments with high temperatures and strong electromagnetic interference.
Machinery manufacturing plants: Used for automated production lines, robotic workstations, and packaging equipment control.

Features

• High-accuracy piezoelectric dynamic pressure measurement
• Compatible with IPC707 diagnostic signal systems
• Optimized for short MI cable configuration
• Stable performance under extreme temperature conditions
• Strong resistance to industrial vibration and EMI

Functions

• Converts dynamic pressure into stable charge signals
• Supports diagnostic-based condition monitoring systems
• Ensures reliable signal integrity across measurement chain
• Enhances turbine and rotating machinery protection
• Reduces interference in high-noise industrial environments

FAQ

Q1: What is CP232 143-232-000-222 used for?
A1: It is used for dynamic pressure measurement in turbines, industrial machinery, and monitoring systems.

Q2: Is CP232 compatible with IPC707 systems?
A2: Yes, it is specifically designed for use with IPC707 signal conditioners with diagnostic capability.

Q3: What cable length is recommended for CP232?
A3: It is recommended to use MI cables not exceeding 0.3 m for proper diagnostic performance.

Q4: Can CP232 operate in high-temperature environments?
A4: Yes, it supports continuous operation up to 520°C in harsh industrial conditions.

Q5: Why is cable length important for CP232?
A5: Longer MI cables can affect capacitance and reduce diagnostic accuracy in the measurement chain.

Spares

900R12-0300

900R08R-0300

900R12R-0300

900R01-0300

900PSM-0200

900S75-0460

900S50-0460

900P01-0501

900P24-0501

900C70-0460

900C50-0460

900C30-0460

900RR0-0300

900C75-0560

900RSM-0200

900C70S-0460

900C50S-0460

900C30S-0460

900RR0-0300

900C75S-0560

900RSM-0200

900S75S-0460

900S50S-0460

900P01-0601

900P24-0601

900U02-0100

900A01-0202

900A16-0103

900B01-0301

900B08-0202

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000