abb ac500 eco s500 eco do562 16 channel digital output module with 24 v dc transistor outputs original new-0

ABB

Home >  Products >  ABB

ABB AC500-eCo S500-eCo DO562 16-channel digital output module with 24 V DC transistor outputs | Original New

ABB AC500-eCo S500-eCo
DO562
16-channel digital output module with 24 V DC transistor outputs.
KEY SPECS: 16 DO; 24 V DC; 0.5 A per channel; 8 A group maximum.
LEAD TIME: In stock    WARRANTY: 1 year
Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • I/O Functions
  • Electrical Data
  • Installation
  • Environment
  • FAQ
  • Recommend Models
  • Recommended Products
ABB AC500-eCo S500-eCo DO562
The DO562 is an S500-eCo digital output module with sixteen transistor channels. It is powered through the I/O bus and uses a separate 24 V DC process supply for the field outputs.

Technical Data

Complete model
DO562
Order number
1SAP230900R0000
Product family
ABB AC500-eCo / S500-eCo
Product type
Digital output module
Digital outputs
16 transistor outputs, 24 V DC
Rated output current
0.5 A per channel; 8 A maximum for the group
Process supply voltage
24 V DC via UP and ZP terminals
Current consumption
Approx. 10 mA from the CPU or interface supply; 20 mA plus output load via UP
Output delay
50 us from 0 to 1; 200 us from 1 to 0
Output protection
External 3 A fast fuse per channel; outputs are not short-circuit or overload protected
Terminal connection
Removable 9-pin and 11-pin terminal blocks
Dimensions
Approx. 34 x 135 x 84.2 mm (W x H x D)
Weight
Approx. 125 g
Mounting
DIN rail or screw mounting; horizontal or vertical
Operating temperature
0 to 60 C horizontal; 0 to 40 C vertical
Storage temperature
-40 to 70 C
Ingress protection
IP20
Maximum cable length
500 m shielded; 150 m unshielded

I/O Functions

Output channels
Sixteen transistor outputs O0 to O15 form one isolated 24 V DC group with 0.5 A maximum per channel.
Signal indication
Sixteen yellow LEDs display the individual output states when the module is powered through the I/O bus.
Data exchange
The module uses two output bytes for the sixteen digital channels.

Electrical Data

Process supply
UP terminal 19 accepts +24 V DC and ZP terminal 20 provides the 0 V reference for all outputs.
Group capacity
The sixteen-channel group supports up to 8 A total. Lamp loads are limited to 5 W per channel.
External protection
The outputs are not internally protected against short circuit or overload; ABB specifies a 3 A fast fuse for each channel.

Installation

Terminal blocks
O0 to O7 use the 9-pin block; O8 to O15, UP and ZP use the 11-pin block. Terminal blocks are ordered separately.
Station use
Use as centralized AC500 expansion or behind supported S500 communication interfaces; the module is not intended for CI590-CS31-HA stations.
Cooling clearance
Maintain at least 20 mm around the installed station and keep cable ducts clear of natural convection airflow.

Environment

Enclosure protection
IP20 equipment must be installed in a suitable control enclosure with all terminal blocks and covers correctly fitted.
Temperature and storage
The S500-eCo system range is 0 to 60 C horizontal, 0 to 40 C vertical and -40 to 70 C for storage.
Safe handling
Remove all supply and process voltage before wiring, inserting or removing the module, and use SELV or PELV supplies.

FAQ

Q1. How can the quoted DO562 be verified?
Match the complete model DO562 and ABB order number 1SAP230900R0000 on the nameplate, packaging and quotation.
Q2. How can New, Used and Refurbished condition be distinguished?
Request close-up photos of the label, terminal areas, DIN-rail latch and housing. Prior wiring marks, rail wear or replacement labels may indicate use or repair.
Q3. How should a supplier be checked?
Verify company registration, physical address, bank beneficiary and references, and require a written quotation naming DO562 and 1SAP230900R0000.
Q4. Which technical points need engineering approval?
Confirm sixteen 24 V DC transistor outputs, 0.5 A per channel, 8 A group limit, external 3 A fast fuses, terminal-block type and S500 station compatibility.
Q5. What evidence should be obtained before payment?
Ask for dated photos or video showing the ABB label, order number, production markings, housing and both terminal-block areas, plus any included accessories.
Q6. Can DO561 or another similar module replace DO562?
No direct substitution should be assumed. DO561 has eight outputs and a different terminal allocation; wiring, load current and configuration must be reviewed.

Recommend Models

SM560-S
6ES7517-3FP00-0AB0
TC-FXX102
6ES7654-7HY00-0XA0
6ES7511-1TK01-0AB0
VE3051C2
ATA4D
TB851
1756-A10
ACCC01
DI562
TU842
6ES7321-7BH01-0AB0
1769-L36ERM
TB541-ETH
6ES7417-4HL04-0AB0
KJ2002X1-BA1
AFV30D
6ES7211-1AE40-0XB0
DI524
1756-L905TS
PM851K01
CC-PCNT03
6ES7522-1FH00-0AA0
TU844
1756-A4
1756-L71
1756-PA72
6ES7231-5QD32-0XB0
ADV557
SD832
TU843
KJ1501X1-BC1
6EP3331-6SB00-0AY0
6ES7288-1ST40-0AA1
TU515
AFV30S
6ES7331-7NF00-0AB0
6ED1055-1CB10-0BA2
CC-TCNT04
CI873K01
6ES7513-1RL00-0AB0
6ED1055-4MH08-0BA1
AAR181
CC-TCNT01
1756-L74
6ES7654-7HC00-0XA0
CC-PCNT02
TB561-ETH
6ES7232-4HD32-0XB0
CI854AK01
CI521-MODTCP
CI865K01
6ES7288-5AE01-0AA0
5069-L340ERM
TU847
PM858K01
6ES7288-1CR30-0AA0
6ES7288-5CM01-0AA0
1756-IT6I

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000