LEAD TIME: In stock
|
WARRANTY: 1 year
|
|
Complete model
|
1756-CN2R
|
|
Brand
|
Allen-Bradley / Rockwell Automation
|
|
Product family
|
ControlLogix 1756
|
|
Product type
|
Redundant ControlNet communication interface module
|
|
Lifecycle status
|
Active Mature
|
|
Configuration
|
Redundant
|
|
Communication network
|
ControlNet
|
|
Communication rate
|
5 Mbps
|
|
Logix communication connections
|
128
|
|
Connections supported
|
131 maximum, including three reserved for redundant control
|
|
Network nodes
|
99 maximum
|
|
ControlNet ports
|
Two ControlNet BNC ports
|
|
ControlNet cable
|
1786-RG6 quad-shield RG6 coaxial cable
|
|
USB port
|
USB full speed, 12 Mbps, for temporary local programming
|
|
Current draw at 5.1 VDC
|
1300 mA
|
|
Current draw at 24 VDC
|
3 mA
|
|
Power dissipation
|
6.7 W
|
|
Thermal dissipation
|
22.9 BTU/hr
|
|
Isolation voltage
|
30 V continuous, basic insulation; type tested at 500 VAC for 60 seconds
|
|
Dimensions
|
Numeric dimensions are not stated in official publication 1756-TD003; one-slot chassis module, official drawing 32517-M
|
|
Weight
|
Approximately 0.293 kg (0.64 lb)
|
|
Slot width
|
One ControlLogix chassis slot
|
|
Module location
|
Chassis-based, any slot
|
|
Compatible chassis
|
1756-A4, 1756-A7, 1756-A10, 1756-A13 and 1756-A17
|
|
Enclosure type
|
None, open-style equipment
|
|
Wiring category
|
Category 1 on ControlNet ports; Category 3 on USB ports
|
|
Operating temperature
|
0 to 60 degrees C
|
|
Storage temperature
|
-40 to +85 degrees C
|
|
Relative humidity
|
5 to 95 percent, noncondensing
|
|
Vibration
|
2 g at 10-500 Hz
|
|
Shock
|
30 g operating and 30 g nonoperating
|
|
Certifications
|
cULus, CSA, CE, RCM, KC, ATEX, IECEx, FM, UKCA, UKEx, ABS, RINA, ODVA, EAC, Morocco and CCC when marked
|
|
Official sources
|
Rockwell Automation 1756-CN2R product page; publication 1756-TD003Q-EN-E pages 25-29; installation publication 1756-IN074
|
|
ControlNet A and B
|
Connect redundant ControlNet media to the two BNC ports using the specified 1786-RG6 quad-shield RG6 coaxial cable and approved taps.
|
|
USB connection
|
Use the USB port only for temporary local programming; Rockwell Automation does not specify it for permanent installation or hazardous-location use.
|
|
Backplane interface
|
Install the module in one slot of a compatible 1756 chassis; it draws 1300 mA at 5.1 VDC and 3 mA at 24 VDC from the backplane.
|
|
Network addressing
|
Set the ControlNet node address before installation and verify that it is unique on the network.
|
|
6ES7322-8BF00-0AB0
|
A-13543-001
|
8320G176 120/60,110/50
|
|
C22965
|
P3124-PSI
|
VCZAM1100/U
|
|
WMZH1C15
|
C0-16ND3
|
M10SS600M
|
|
F351B1-301
|
DEP218/AS-BDEP-218
|
M38490
|
|
KL3202
|
5VX950
|
15738-179
|
|
08056D106KAT2A
|
B3DA9100
|
7700-51101-S4X0200
|
|
Z-200-OTLT-RIOF
|
2608D22G03
|
BL5005
|
|
DRTS-6
|
MC-2
|
BM200-DDT
|
|
8564E
|
EC-200
|
MHZ2-25D
|
|
750-1504
|
OPVXG-EXPT
|
R40-227-BNEA
|
|
MUC207V
|
NEKM-C6-C45-P3-D
|
8000-84060-0000000 EXACT8,4XM8
|
|
FNC-32
|
3RT2016-1BB42-1AA0
|
EA170-12100
|
|
45UV5-1010
|
1-610-0157
|
L23230X-2
|
|
XL34-2K5A2
|
Z02-115 - 02-115
|
EN50044
|
|
VMPA2-M1H-J-PI
|
266A986AFP17 CSR7714
|
LRD04
|
|
12M8A-C8L-1-T-SS
|
758-873
|
WMZH2C25T
|
|
L11BB7520
|
XE7 ACE7
|
PHD-4
|
|
UCSA-H1A + IS420ESWBH2A + IS200JPDVG1AAA
|
FBM242 P0916MU-0A P0916MT
|
10E3T3N-2/50
|
|
CC-PCNT02 PN:51454551-275
|
Ge DS2020DACAG2
|
GE VMIVME-7807RC
|
|
PMI 538, 264538
|
5531088 SCD 023-009-030
|
SY7120-5YO-02N
|