LEAD TIME: In stock
|
WARRANTY: 1 year
|
|
Complete model
|
1756-DNB
|
|
Brand
|
Allen-Bradley / Rockwell Automation
|
|
Product family
|
ControlLogix 1756
|
|
Product type
|
DeviceNet bridge and scanner communication module
|
|
Lifecycle status
|
Active
|
|
Communication network
|
DeviceNet
|
|
Number of channels
|
1
|
|
Communication rates
|
125 Kbps, 250 Kbps or 500 Kbps
|
|
Maximum trunk length
|
500 m at 125 Kbps; 250 m at 250 Kbps; 100 m at 500 Kbps
|
|
Network nodes
|
64 maximum
|
|
DeviceNet voltage range
|
11 to 25 VDC, Class 2 / SELV
|
|
DeviceNet current draw
|
60 mA at 24 VDC
|
|
Backplane current draw
|
400 mA at 5.1 VDC; 0 mA at 24 VDC
|
|
Power dissipation
|
3.5 W
|
|
Thermal dissipation
|
11.9 BTU/hr
|
|
DeviceNet port
|
One open-style 5- or 10-pin linear plug
|
|
USB port
|
USB full speed, 12 Mbps, for temporary local programming
|
|
Isolation voltage
|
50 V continuous, basic insulation, DeviceNet network to backplane; type tested at 853 VAC for 60 seconds
|
|
Dimensions
|
Numeric dimensions are not stated in official publication 1756-TD003R; one-slot ControlLogix chassis module
|
|
Weight
|
Not stated in official publication 1756-TD003R for this exact catalog number
|
|
Slot width
|
One ControlLogix chassis slot
|
|
Module location
|
Chassis-based, any slot
|
|
Compatible chassis
|
1756-A4, 1756-A7, 1756-A10, 1756-A13 and 1756-A17
|
|
Enclosure type
|
None, open-style equipment
|
|
Operating temperature
|
0 to 60 degrees C
|
|
Storage temperature
|
-40 to +85 degrees C
|
|
Relative humidity
|
5 to 95 percent, noncondensing
|
|
Vibration
|
2 g at 10 to 500 Hz
|
|
Shock
|
30 g operating; 50 g nonoperating
|
|
Certifications
|
cULus, CSA, CE, RCM, ATEX, IECEx, UKEX, UKCA, KC, EAC and CCC when marked
|
|
Official sources
|
Rockwell Automation 1756-DNB product page; publication 1756-TD003R-EN-E pages 15 to 17; publication 1756-IN566
|
|
DeviceNet network
|
Use the open-style DeviceNet connector and an 11 to 25 VDC Class 2 / SELV network supply.
|
|
Network power
|
Allow for the published 60 mA DeviceNet current draw at 24 VDC.
|
|
USB connection
|
Use the USB port only for temporary local programming; it is not intended for permanent connection or hazardous-location use.
|
|
Backplane interface
|
Install the module in one slot of a compatible 1756 chassis and include 400 mA at 5.1 VDC in the backplane power budget.
|
|
STR82D-22E02J0-GFAGG00A0-A-CDC
|
T100F1395
|
1707-S1-T26B
|
|
51961-39
|
2FW-BV-008A 2FW-BV-008B
|
TK-0N 4NK0AA
|
|
FSM-80S
|
HPA5091-03-01
|
QRS411
|
|
V3240809S
|
MTST230V 70C1056G54
|
8501-CG14
|
|
08056D106KAT2A
|
03-234-711-003
|
MHSV-4B
|
|
P2S-EA162D25AT
|
UTP1
|
Elite 41-1
|
|
VG-253K-S-12-MC
|
GE VME-7807RC-412000-350-93007807-412000G
|
1522312 SAC-6P-M
|
|
ARA20 766A029G01
|
140-MN-0100
|
9905-863
|
|
2002-1206
|
3ZA4041-8AL00
|
3RT2016-1BB44-3MA0
|
|
SL-SW1050
|
029-24758-002
|
AIF01A A03B-0807-C011
|
|
2KTEM-1000
|
PN:2155/40-01
|
DBL175
|
|
RCJ221
|
102D
|
C70TC3HKHF8NH6DM8VP67U67W67
|
|
TROF1P24D
|
Ge Is215ucveh2af
|
EP0BMJ1-M6
|
|
PEV-1/4-B
|
766A026G01
|
EVA-L-SHB
|
|
MS3126F14-5S
|
SPGX0703-C1 T3000D
|
136634-0010-01
|
|
MMX8x4-HT420M
|
DEE2R-88D
|
D15CR31
|
|
HIMA F 8650X PN 98 4865066
|
RT-L250
|
CBT-K55,1153.9000.35
|
|
A-100
|
729 30G
|
WMZH2D20
|
|
Z02-115 - 02-115
|
CPX-AB-8-M8-3POL
|
VBGT 16 04 08-UM
|
|
7XS5403-0AA00
|
7700-51101-S4X0200
|
SC-4-0
|