LEAD TIME: In stock
|
WARRANTY: 1 year
|
|
Complete model
|
1756-IB16D
|
|
Brand
|
Allen-Bradley / Rockwell Automation
|
|
Product family
|
ControlLogix 1756
|
|
Product type
|
DC diagnostic digital input module
|
|
Inputs
|
16 diagnostic inputs, 4 points per group
|
|
Voltage category
|
12/24 VDC sink
|
|
Operating voltage range
|
10-30 VDC
|
|
Nominal input voltage
|
24 VDC
|
|
Off-to-on delay
|
340 us nominal, 1 ms maximum, plus 0 ms, 1 ms or 2 ms selectable filter
|
|
On-to-off delay
|
740 us nominal, 4 ms maximum, plus 0 ms, 1 ms, 9 ms or 18 ms selectable filter
|
|
Current draw at 5.1 V
|
150 mA
|
|
Current draw at 24 V
|
3 mA
|
|
Total backplane power
|
0.84 W
|
|
Power dissipation
|
5.8 W maximum at 60 degrees C
|
|
Open-wire diagnostic threshold
|
1.2 mA minimum off-state leakage current
|
|
Diagnostic time stamp
|
+/-1 ms
|
|
Input time stamp
|
+/-200 us
|
|
On-state current
|
2 mA minimum at 10 VDC; 13 mA maximum at 30 VDC
|
|
Input impedance
|
2.31 kOhm maximum at 30 VDC
|
|
Isolation voltage
|
250 V continuous, basic insulation, inputs-to-backplane and group-to-group; no isolation between inputs in one group
|
|
Removable terminal block
|
1756-TBCH or 1756-TBS6H, ordered separately
|
|
Dimensions
|
144.5 x 34.6 x 146.9 mm, height x width x depth
|
|
Weight
|
Approximately 0.2 kg (0.5 lb)
|
|
Slot width
|
One ControlLogix chassis slot
|
|
Enclosure type
|
None, open-style equipment
|
|
Operating temperature
|
0 to 60 degrees C
|
|
Storage temperature
|
-40 to +85 degrees C
|
|
Relative humidity
|
5 to 95 percent, noncondensing
|
|
Vibration
|
2 g at 10-500 Hz
|
|
Shock
|
30 g operating; 50 g nonoperating
|
|
Certifications
|
cULus, CE, RCM, KC, ATEX, IECEx, UKEx, FM, UKCA, Morocco and CCC when marked
|
|
Lifecycle
|
Active
|
|
Official sources
|
Rockwell Automation product page; publication 1756-TD002T-EN-E pages 49-52; official drawing ABIOM091; Rockwell ControlLogix 1756 system reference
|
|
Field wiring
|
Use a 1756-TBCH or 1756-TBS6H 36-pin removable terminal block housing; the RTB is ordered separately.
|
|
Input groups
|
Inputs IN-0 through IN-15 are divided into four groups with corresponding group ground connections.
|
|
Leakage resistors
|
Rockwell lists 3.3 kOhm at 10 VDC, 5.6 kOhm at 12 VDC, 15 kOhm at 24 VDC and 20 kOhm at 30 VDC, each 1/4 W and 5 percent.
|
|
Backplane
|
The module draws 150 mA at 5.1 V and 3 mA at 24 V from the ControlLogix backplane.
|
|
5201KDD
|
E3S-AT11-L
|
GE CR2810A14DE
|
|
KA34U
|
LC1D09
|
EQP-1A
|
|
R9853350
|
TL-M2ME2
|
SLHFSW6
|
|
A-5000-3712
|
4PDK7
|
AN41A
|
|
6ES7322-1BL00-0AA0
|
CMC-225-IS
|
6KD73
|
|
QS-H150
|
GNS-430 011-00280-10
|
BR2C25UC
|
|
GE IS200JPDFG1A GE IS200JPDFG1AED
|
10654
|
2D-3S-2A-3E
|
|
D254
|
0LR0453
|
15021G002
|
|
289312
|
IS220UCSAH1A / UCSA-H1A
|
11NR16UN CP500
|
|
GE IS200ECTBG2A-DE
|
3RH21221BB40
|
C306TB1
|
|
B1200-8192358/WKM
|
10E3T3N-2/50
|
IAS-20-A24-S
|
|
CPX-GE-EV-S-7/8-5POL
|
548-49
|
VCZAA1100/U
|
|
NGS-3U
|
A03B-0815-C001
|
OEM24N5.4-9
|
|
IC330-18S
|
1746-IV16
|
CEI33-3
|
|
DMB01
|
AP4268
|
TK-5-1N TR20EW-W
|
|
3VA9110-0WC00
|
MTK2000
|
8170-5PL-A
|
|
MSH8-8A
|
MAX-720 MAX-720C-Q1-EI-EI
|
S811+T24N3
|
|
YG-1 07426 E2039064
|
MEA-2
|
71-100234-00
|
|
2004-437
|
ZU-335
|
341-0257-01A0
|
|
ABB MDI32BIS 001-1104-07-02
|
3/8'' 3401 MA3
|
MSO 4054
|