LEAD TIME: In stock
|
WARRANTY: 1 year
|
|
Complete model
|
1756-PB75
|
|
Brand
|
Allen-Bradley / Rockwell Automation
|
|
Product family
|
ControlLogix 1756
|
|
Product type
|
Standard 24 VDC chassis power supply
|
|
Lifecycle status
|
Active
|
|
Input voltage range
|
18 to 32 VDC; official product description states 19 to 32 VDC
|
|
Nominal input voltage
|
24 VDC
|
|
Input power
|
95 W maximum
|
|
Output power
|
75 W maximum at 0 to 60 degrees C
|
|
Output current at 1.2 VDC
|
1.5 A
|
|
Output current at 3.3 VDC
|
4 A
|
|
Output current at 5.1 VDC
|
13 A
|
|
Output current at 24 VDC
|
2.8 A
|
|
Hold-up time
|
35 ms at 18 VDC; 40 ms at 24 VDC; 40 ms at 32 VDC
|
|
Isolation voltage
|
250 V continuous, reinforced insulation, power input to backplane; type tested at 3500 VDC for 60 seconds
|
|
Dimensions
|
Approximately 14.0 x 11.2 x 14.5 cm (5.51 x 4.41 x 5.71 in.), H x W x D
|
|
Mounting dimensions
|
Height 14.0 cm (5.51 in.); width 11.2 cm (4.41 in.)
|
|
Weight
|
Approximately 0.95 kg (2.10 lb)
|
|
Module location
|
Left side of compatible 1756 chassis
|
|
Compatible chassis
|
1756-A4, 1756-A7, 1756-A10, 1756-A13 and 1756-A17; Series B and Series C for 1756-PB75/B
|
|
Connection cable
|
None required for backplane output; field input wiring uses 2.5 mm2 (14 AWG) copper wire rated 90 degrees C or higher
|
|
Conductor screw torque
|
0.565 N m (5 lb in)
|
|
Enclosure type
|
None, open-style equipment
|
|
Temperature code
|
T4
|
|
Operating temperature
|
0 to 60 degrees C
|
|
Storage temperature
|
-40 to +85 degrees C
|
|
Relative humidity
|
5 to 95 percent, noncondensing
|
|
Vibration
|
2 g at 10 to 500 Hz
|
|
Shock
|
30 g operating and 50 g nonoperating
|
|
Certifications
|
cULus, CE, ATEX, IECEx, UKCA, RCM, CCC, EAC and ABS when product markings apply
|
|
Official sources
|
Rockwell Automation 1756-PB75 product page; publication 1756-TD005J-EN-P pages 6-8; installation publication 1756-IN619 pages 1 and 5-7
|
|
Combined output limit
|
The combined loading of the 1.2, 3.3, 5.1 and 24 VDC backplane outputs must not exceed 75 W.
|
|
5.1 VDC rail
|
Up to 13 A for ControlLogix chassis loads.
|
|
3.3 VDC rail
|
Up to 4 A for supported backplane loads.
|
|
1.2 and 24 VDC rails
|
Up to 1.5 A at 1.2 VDC and 2.8 A at 24 VDC.
|
|
Input wiring
|
Use 2.5 mm2 (14 AWG) solid or stranded copper wire rated 90 degrees C or higher and tighten the conductor screw to 0.565 N m.
|
|
92004845-1
|
SSR2
|
COM-120C
|
|
CRPHASE3001A02
|
TN-200HL
|
2604D30G08
|
|
VCZAA1100/U
|
55-201503P1
|
MEA-2
|
|
PB5322
|
UMS-1XP
|
LXG441.99.21200 FP360
|
|
PAK1 7/16
|
7000-12761-0000000
|
FAZ-XHIN11-SP
|
|
HE-XPVA-40
|
EVF3133-3LZ-02
|
WMZH2C25T
|
|
SS-QT8-D-16PF
|
ES H90 EC-1
|
VQ7-6-FIG-D-3ZR
|
|
CP95SDB50-50
|
MS3126F14-5S
|
V3240809S
|
|
1492-H
|
DMB01
|
465215
|
|
DF868 / DF868-2-14-10000-0
|
NVFS3210-5DZ 24vdc VFS3000
|
I-T-E 2190-E21AA-MOD
|
|
NP8314C13E
|
200A-3PH/ED
|
PHD-4
|
|
373D958G16
|
IS220PDIOH1B
|
CSTVP-0752-CF
|
|
0294402244CC
|
HS2515
|
GE P112-6053
|
|
IAS-20-A24-S
|
CE3020
|
6311 2ZJEM
|
|
UCP206-30MM
|
3RH2921-1DA02
|
NGCPB10AX01B
|
|
DTFNR164D
|
OP-27934
|
AP35-S1G-L
|
|
6SL3352-1AE37-5BA1
|
2910-3014-00
|
SA53A
|
|
WMZH2C15
|
3RH21221BB40
|
C10CX C10C-1
|
|
VMPA2-FB-AP-2-1-S0
|
03-234-711-003
|
05804-318 ER20
|
|
PMK-JY-M
|
4118M-065-30RO
|
7600-ES+2TG3CXL
|