emerson deltav m series series 2 kj3222x1 ba1 8 channel 4 20ma hart redundant analog input card-0

EMERSON Delta V

Home >  Products >  EMERSON >  EMERSON Delta V

Emerson DeltaV M-series Series 2 KJ3222X1-BA1 8-Channel 4-20 mA HART Redundant Analog Input Card

Emerson DeltaV M-series Series 2 8-Channel 4-20 mA HART Redundant Analog Input Card
Complete Model
KJ3222X1-BA1
Official Product Description
Emerson KJ3222X1-BA1 DeltaV M-series Series 2 eight-channel 4-20 mA HART analog input card for simplex or redundant I/O use.
CORE FEATURE: Eight high-resolution 4-20 mA HART inputs with supported redundant I/O operation.
LEAD TIME: In stock
WARRANTY: 1 year

Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • Applications & Features
  • Connections
  • Installation
  • Environment
  • FAQ
  • Recommend Models
  • Recommended Products
Product Overview
KJ3222X1-BA1 is an Emerson DeltaV M-series Series 2 eight-channel 4-20 mA HART analog input card designed for simplex or redundant I/O applications.
The official PDS specifies a 1 to 22.5 mA full input range, 0.1 percent span accuracy, 16-bit conversion, 0.05 percent repeatability and HART pass-through for AMS Device Manager.
The exact instruction sheet identifies 12 VDC LocalBus power at 150 mA, 24 VDC field power at 300 mA, A1 keying and a -40 to +70 degrees C ambient range.

Technical Data

Complete model
KJ3222X1-BA1
Brand
Emerson
Product family
DeltaV M-series Series 2 Traditional I/O
Product type
8-channel 4-20 mA HART analog input card for simplex or redundant operation
Number of channels
8
Nominal input range
4 to 20 mA
Full input range
1 to 22.5 mA with overrange checking
HART support
HART pass-through for AMS Device Manager; variables and status available for control functions
Accuracy over temperature
0.1 percent of span
Resolution
16-bit A/D converter
Repeatability
0.05 percent of span
Frequency response
-3 dB at 2.7 Hz; -20.5 dB at one-half sampling frequency
HART scan time
600 to 800 ms typical per enabled channel
Isolation
Each channel optically isolated from the system and factory tested to 1500 VDC
LocalBus current
Simplex 120 mA typical, 150 mA maximum; redundant 175 mA typical, 250 mA maximum per card
Bussed field power
24 VDC at 300 mA
Field-circuit rating
24 VDC at 30 mA
Terminal-block key
A1
Termination options
Standard, redundant standard, fused, four-wire, 16-pin and 24-pin mass termination
Dimensions
10.7 x 4.1 x 10.5 cm, height x width x depth
Weight
Not specified in the official sources reviewed
Protection rating
IP20 component
Operating temperature
-40 to +70 degrees C
Certifications
FM13ATEX0034U; IECEx FMG 13.0015U; FM Class I Division 2 Groups A-D T4, subject to the exact product label
Official sources
Emerson instruction sheet ATEX134 page 1; DeltaV M-series Traditional I/O PDS pages 4, 5, 26, 28 and 29; Zone 2 instruction 12P2046 page 12

Inquiry

Applications & Features

Eight HART inputs
Eight 4-20 mA channels support HART variables and device status.
Redundant I/O capability
The BA1 card is identified for redundant application and is listed with a redundant standard terminal block.
High-resolution conversion
The input path provides 16-bit conversion with 0.1 percent span accuracy.
AMS pass-through
HART pass-through supports compatible device access through AMS Device Manager.

Connections

Two-wire inputs
Use the approved A1-keyed standard, fused or 16-pin termination arrangement.
Four-wire inputs
Use the approved four-wire or 24-pin mass-termination arrangement with the required external transmitter supply.
Redundant termination
Use the listed redundant standard terminal block when the DeltaV architecture requires paired cards.
LocalBus
12 VDC nominal with distinct simplex and redundant current limits.
Bussed field power
24 VDC at 300 mA.
Channel circuit
24 VDC at 30 mA on the exact instruction sheet.

Installation

01 - Verify the BA1 suffix
Match KJ3222X1-BA1 on the label, quotation and dated photos; do not treat BA2 as the same compatibility variant.
02 - Confirm simplex or redundant use
Select the standard or redundant A1-keyed terminal hardware required by the installed DeltaV architecture.
03 - Choose transmitter wiring
Use the approved two-wire or four-wire termination and field-power arrangement.
04 - Validate signal performance
Confirm 4-20 mA scaling, HART requirements, input frequency response and the LocalBus and field-power budgets.
05 - Apply certified procedures
Follow ATEX134 and the site requirements before field wiring, card removal or insertion.

Environment

Ambient temperature
-40 to +70 degrees C on the exact instruction sheet.
Storage temperature
-40 to +85 degrees C in the current M-series Traditional I/O data sheet.
Protection
IP20 component; install in the enclosure required by the site and certification.
Relative humidity
5 to 95 percent, non-condensing.
Shock
10 g half-sine wave for 11 ms.
Airborne contaminants
ISA-S71.04-1985 Class G3 with conformal coating.
Maintenance
No user-serviceable parts; calibration is not required unless the exact card documentation states otherwise.

FAQ

Q1. How can the exact quoted KJ3222X1-BA1 be verified?
Match KJ3222X1-BA1 on the label, quotation and dated photos. Confirm eight 4-20 mA HART inputs, A1 keying and the redundant-card identification.
Q2. How can New, Used or Refurbished condition be distinguished?
Request current images of the label, A1 keying, indicators, contacts, terminal interface and packaging. Inspect for insertion marks from paired-card service, repairs or changed labels.
Q3. How should supplier legality and reliability be checked?
Verify the legal entity, registered address, payment beneficiary and traceable contact. The offer must state Emerson, KJ3222X1-BA1, HART AI card, condition and quantity.
Q4. Which specifications must engineering confirm before purchase?
Confirm eight 4-20 mA HART inputs, simplex or redundant use, 16-bit resolution, A1 keying, two-wire or four-wire termination, power budgets and firmware compatibility.
Q5. What physical evidence should be requested before payment?
Ask for date-marked photos showing the complete nameplate, serial data, A1 keying, indicators, rear contacts and the exact terminal-block interface.
Q6. Can a different suffix replace KJ3222X1-BA1?
Not automatically. KJ3222X1-BA1 is identified for the newer supported terminal arrangements and redundant application. Verify system version and terminal hardware before substituting any other suffix.

Recommend Models

753-478
SSA-EB1PL1-22
204D1383P001
AADE0375J3CRB
CP451-50
C370BN
R-270
SW2L-64-HSB-DP
XC3S1500 FG676AFQ0433
743040115
30-8000
11NR16UN CP500
B6-30-10
UCP206-30MM
THC3465
C47 1-1/4
GE CR120B100
SY7120-5YO-02N
12MSEL8N-B
MPCKT55NAX20N
1485P-P4T5-T5
AF1-B0-34-615-1G1-C
8WH9020-6CD10
3WA9111-0EC61
LG-2FPA-16-NS-GR
KJ4010X1-BF1
ABB M2SS1-40B-10
DC5-24V
WMZH2C15
XTRIR2
RADIOFLEX-300EGS.2
823278-C6
7SD5321-4PB99-9HL6
3RH1921-1EA20
4XHBU-SS
D26MR402
OPDS-MP-0155-I1
ABB MDI32BIS 001-1104-07-02
MMX8x4-HT420M
D4JL-K2
011-DFGV
AR420A 766A024G01
028249-001
N0141-ZT
152SA400E
8503AA3A3MA0020
E22C9T、E22C7T
313C590G14
FAZ-C6/1-NA-L
SL1-F
Allen Bradley 1778-IBC
FAZ-C5/3
TM8
7700-44711-S4U1000
FL2-4D6H-L3
Oct-00
SWG500
V55LB2075
WMZT1DX0T
E5C2-R20

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000