| Sales | Phone/Whatsapp | |
|---|---|---|
| Jim Pei | [email protected] | +86 18020776782 |
| Model | PR6423/000-101 CON041 |
|---|---|
| Product Family | PR6423 / CON041 |
| Product Type | 8 mm eddy current measuring chain |
| Sensor Model | PR6423/000-101 |
| Converter Model | CON041 |
| Probe Diameter | 8 mm |
| Measurement Method | Non-contact eddy current |
| Linear Range | 2 mm |
| Initial Gap | 0.5 mm |
| Sensitivity | 8 V/mm ±5% |
| Deviation from Straight Line | ±0.025 mm |
| Minimum Shaft Diameter | 25 mm |
| Target Material | 42CrMo4 / AISI 4140 |
| Sleeve Thread | M10 × 1 |
| Cable Armor | Without |
| Sleeve Length | 25 mm |
| Adapter Plug | Without |
| Total Cable Length | 4 m |
| Cable End | Open |
| Sensor Protection | IP66 |
| Sensor and 1 m Cable Temperature | -35 to 180°C |
| Remaining Cable Temperature | -35 to 150°C |
| Converter Supply | -24 VDC nominal |
| Converter Output | -2 to -18 V |
| Converter Frequency Range | 0 to 20 kHz |
| Converter Mounting | DIN rail |
| Converter Protection | IP20 |
| Product Dimensions | 16 × 15 × 2 cm |
| Weight | 0.15 kg |
| Minimum Order Quantity | 1 Piece |
|---|---|
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3–7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
Functioning as a Emerson EPRO 8 mm eddy current measuring chain, PR6423/000-101 CON041 belongs to the PR6423 / CON041 platform. It uses the shortest twenty-five-millimetre M10 sleeve in this batch for compact mounting positions. The model-specific arrangement provides a four-metre unarmored cable without an intermediate adapter plug. Its installed interface terminates in an open cable end sized for the CON041 screw-terminal connection. These characteristics define the exact hardware boundary that must be matched when the component is sourced for an existing system.
During shutdown preparation, PR6423/000-101 CON041 supports compact bearing housings while maintaining the documented short cable runs path. The component is especially relevant where radial vibration monitoring must remain predictable after service. Before removal, technicians should record the host location, connector orientation and project settings that govern panel-near conversion. Delivers the standard 8 mm probe sensitivity for shaft gap and dynamic movement monitoring. A controlled functional test should then confirm the restored path before the equipment returns to normal operation.
| IB-150 99-000008-02 | BN-2-D | 1762-OF4 |
| 113dg | MTN6700-0004 | DCP2-2405 1240020009A |
| Z90e-SI | S2HC 472406 | HR3D28KUTC3BB |
| MP-500PA | SB-RLY12c10A | SB-DN-PS750 |
| EIR505-M | TM168B23S | reg-k/4x230/16 |
| V61R513A-A2000 | 311025A | 2CDG 120 039 R0011 |
| MG5424 | SG-TL70-Y / SGTL70Y | RH10E |
| DP-DL01D | CCT15244 | DIM-2CH-6A |
| 88974031 CB20 | BMXDDI3202K | EST3 |
| MBC5100 061B000266 | G4 SB-Logic2 | REG-K/8x10 |
| FG32+ BMS | 2CDG 110 085 R0011 | ABB S2-CM2 |
| S4-34741-01 | Feb-41 | K1225 K1225/1 |
| ADV151-P10 | MS-4AOVC | VT9611D3100 |