| Sales | Phone/Whatsapp | |
|---|---|---|
| Jim Pei | [email protected] | +86 18020776782 |
| Model | PR6423/015-111 CON041 |
|---|---|
| Product Family | PR6423 / CON041 |
| Product Type | 8 mm eddy current measuring chain |
| Sensor Model | PR6423/015-111 |
| Converter Model | CON041 |
| Probe Diameter | 8 mm |
| Measurement Method | Non-contact eddy current |
| Linear Range | 2 mm |
| Initial Gap | 0.5 mm |
| Sensitivity | 8 V/mm ±5% |
| Deviation from Straight Line | ±0.025 mm |
| Minimum Shaft Diameter | 25 mm |
| Target Material | 42CrMo4 / AISI 4140 |
| Sleeve Thread | M10 × 1 |
| Cable Armor | With |
| Sleeve Length | 75 mm |
| Adapter Plug | Without |
| Total Cable Length | 5 m |
| Cable End | Open |
| Sensor Protection | IP66 |
| Sensor and 1 m Cable Temperature | -35 to 180°C |
| Remaining Cable Temperature | -35 to 150°C |
| Converter Supply | -24 VDC nominal |
| Converter Output | -2 to -18 V |
| Converter Frequency Range | 0 to 20 kHz |
| Converter Mounting | DIN rail |
| Converter Protection | IP20 |
| Product Dimensions | 20 × 20 × 2 cm |
| Weight | 0.36 kg |
| Minimum Order Quantity | 1 Piece |
|---|---|
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3–7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
Applied as a Emerson EPRO 8 mm eddy current measuring chain, PR6423/015-111 CON041 belongs to the PR6423 / CON041 platform. It uses an M10 × 1 armored probe assembly for mechanically protected cable routing. The model-specific arrangement combines a seventy-five-millimetre sleeve with a five-metre complete cable length. Its installed interface provides an open cable end for landing directly on the CON041 converter terminals. These characteristics define the exact hardware boundary that must be matched when the component is sourced for an existing system.
For troubleshooting, PR6423/015-111 CON041 supports protected cable routes while maintaining the documented turbine shaft monitoring path. The component is especially relevant where axial position measurement must remain predictable after service. Before removal, technicians should record the host location, connector orientation and project settings that govern machine protection input. Supports non-contact radial or axial shaft measurements without mechanical loading. A controlled functional test should then confirm the restored path before the equipment returns to normal operation.
| W7751F2011 | Ddng485 | Q6310074R0111 |
| AK-CC 550 084B8020 | ABB DC532 | ABB 1SAJ530000R1210/UMC100 |
| EKA173/5 | CP3 | EYL0001V0010L02J01 |
| AP-ANT-40 | 1SAJ530000R1210 / UMC100 | ADAM-5000L |
| QUINT-UPS/24DC/24DC/5 | JL085A JL085-61002 X371 | EP1Z01IPHO |
| 1SDA067110R1 | 1SAP250300R0001 | FX0-20MR-ES |
| MTL1143 | 1756-CNBR | SR3B261BD SR3XT141BD |
| HT-3003 | GP370-LG11-24V | ARK 3382 |
| MD-12 | BD-B022 | ABB 1SAP220500R0001 CS31 |
| NT990HDI | WSU26/3-103A00 / 1047985 | LP-FXPM263-0 |
| LP-FX2021N-1 | BA338C | 5WG1 125-1AB21 |
| MC3190-RL3S04E0A | 3/24 1A/21S | BD35 |
| OJ5131 | ME3011C | 1SFA899003R1000 |