Sales
Jim Pei
|
Email
[email protected]
|
Phone/Whatsapp
+86 18020776782
|
|
Model Number
|
750-P5-G5-S5-HI-A1-R-E
|
|
Phase current input rating
|
5 A
|
|
Zero-sequence current input rating
|
5 A
|
|
Sensitive ground current input rating
|
5 A
|
|
DC control power
|
88-300 V DC
|
|
AC control power
|
70-265 V AC
|
|
AC control power frequency
|
48-62 Hz
|
|
Nominal control power burden
|
25 VA
|
|
Maximum control power burden
|
35 VA
|
|
Control power hold-up
|
30 ms
|
|
Analog output channels
|
8
|
|
Analog output range
|
0-1 mA
|
|
Maximum analog output load
|
12 kohm
|
|
Analog output accuracy
|
+/-1% of full scale
|
|
Analog output response
|
Less than 3 power cycles
|
|
Analog output isolation
|
Isolated outputs
|
|
Serial baud rate
|
300-19200 baud
|
|
Serial protocols
|
Modbus RTU; DNP 3.0
|
|
Serial parity
|
Programmable
|
|
Output relay count
|
8
|
|
Trip relay contact form
|
Form A
|
|
Close relay contact form
|
Form A
|
|
Auxiliary relays 3-7 contact form
|
Form C
|
|
Self-test relay 8 contact form
|
Form C
|
|
Relay contact material
|
Silver alloy
|
|
Solid-state trip rating
|
15 A at 250 V DC for 500 ms
|
|
Dielectric withstand
|
2 kV AC for 1 minute
|
|
Operating temperature
|
-40 to +60 C
|
|
Storage and shipping temperature
|
-40 to +85 C
|
|
Maximum relative humidity
|
95%, noncondensing at 55 C
|
|
Pollution degree
|
2
|
|
Front enclosure protection
|
IP40
|
|
Rear enclosure protection
|
IP20
|
|
Breaker-closed indicator
|
Red LED
|
|
Display configuration
|
Enhanced display
|
|
Minimum Order Quantity
|
1 Piece
|
|
Price
|
Contact for Jim
|
|
Packaging Details
|
Original new Factory Sealed
|
|
Delivery Time
|
3–7 Days
|
|
Payment Terms
|
T/T
|
|
Shipping Method
|
DHL / FedEx / UPS / TNT
|
|
Supply Ability
|
In stock
|
GE Multilin 750-P5-G5-S5-HI-A1-R-E is a feeder management relay with an enhanced display. Its ordering code selects phase, zero-sequence and sensitive ground current inputs. The HI power option accepts AC or DC control power. This A1 configuration provides eight 0-1 mA analog outputs. The red indicator identifies the breaker-closed state.
The relay combines feeder protection with metering and control for electrical distribution equipment. Its enhanced front panel supports local operation and inspection. Serial communications connect relay information to supervisory equipment. Match the analog output option to the receiving instrumentation before replacement. The enhanced display suffix alone does not specify an Ethernet interface.
750-P5-G5-S5-HI-A1-R-E supports feeder protection and management in industrial electrical distribution. It can be integrated into switchgear where operators need local indication, metering and protection functions. Coordinate the relay settings with the feeder protection study.
For plant instrumentation upgrades, 750-P5-G5-S5-HI-A1-R-E can transmit selected quantities through its configured analog outputs. Check the receiving equipment and output scaling as part of commissioning. The installed switchgear wiring and protection logic determine the final application.
|
VM-8H
|
7101063006W
|
9050AO10EV02
|
|
HD251X
|
CAN-5901
|
E67I6DQ-O2 AS E67I6DC-O2
|
|
7012AC 1423157-5
|
WH30TQG
|
WRMBL1
|
|
KJ1502X1-BD1
|
M1P 773100 & Pilz pnoz M04p 773536
|
T7W E47 310
|
|
SBD3D-06
|
NTM1A10C
|
DF103V
|
|
BC9100
|
TSP70
|
A1006 M8661Z/B
|
|
1SDA000616R1
|
MP2HI3HCGL
|
EWPC974 C-12V T1L2CWC312
|
|
0007-000001-01 NS3-C
|
DE1-121D4FN-N20N
|
SSA61
|
|
176F3423
|
Epxpns101-Abac
|
UG-3-A4O
|
|
RC87618222
|
CS-AMS8 RS485
|
POL945.00
|
|
ADV151-E10
|
C2ENET-1 C2 ENET-1
|
PGD0000W00
|
|
DI125
|
METSEPM5560 PM5500
|
H4w4per2
|
|
HC30WB5R1
|
KE1051 A004-9
|
5363 EV45
|