Product Name: SafetyNet Discrete Input/Output Module
Brand Name: GE
Model Number:8811-IO-DC-01
Country of Origin:USA
Warranty: 12 Months
Whatsapp:+86 18159889985
Email:[email protected]
Brand Name: |
General Electric |
Model Number: |
8811-IO-DC-01 |
Country of Origin: |
USA |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
Delivery time in stock |
Payment Terms: |
T/T |
|
Sales Manager: |
Stella |
|
Send an email: |
|
|
Contact in Whatsapp: |
|
Parameter |
Specification |
|
Model |
8811-IO-DC-01 |
|
Manufacturer |
GE (General Electric) / Emerson |
|
Product Family |
SafetyNet / PAC8000 |
|
Module Type |
Safety Discrete Input/Output Module |
|
Number of Channels |
8 (independently configurable as inputs or outputs) |
|
Input ON/OFF Threshold Current |
0.9 mA (typical) |
|
Input Wetting Current |
1.2 mA (typical) |
|
Minimum Pulse Width Detected |
5 ms |
|
Max Input Frequency (Pulse Counting) |
30 Hz |
|
Output Current per Channel |
2 A continuous |
|
Output Current per Module (Continuous) |
6 A |
|
Output Current per Module (Non-continuous <10s) |
8 A |
|
Input Filter Time Interval |
0 to 8 s (1 ms steps) |
|
Response Time (Input to Railbus) |
5 ms (max.) |
|
Response Time (Railbus to Output) |
1 ms (max.) |
|
Isolation (Channel to Rails) |
250 VAC |
|
System Power Supply |
50 mA (typ.), 70 mA (max.) |
|
Bussed Field Power Supply (All Inputs) |
50 mA (max.) |
|
Bussed Field Power Supply (Any Outputs) |
50 mA + output load |
|
Module Key Code |
B6 |
|
Module Width |
42 mm |
|
Weight |
210 g |
|
Hazardous Area Location |
Class 1, Div. 2, Groups A,B,C,D T4 |
|
Protection Technique |
EEx nA nL IIC T4 |
|
Certifications |
SIL 2, UL, CE, RoHS, Class I Division 2 |
The 8811-IO-DC-01 is a safety-certified discrete input/output module from GE‘s SafetyNet series, engineered for high-integrity industrial automation and safety instrumented systems. The 8811-IO-DC-01 provides 8 independently configurable channels that can be programmed as either inputs or outputs, offering exceptional deployment flexibility. The 8811-IO-DC-01 is certified for SIL 2 safety-related applications and features non-arcing inputs and outputs for hazardous area operation. With 2 A per channel output capacity and comprehensive internal diagnostics, the 8811-IO-DC-01 delivers reliable performance in demanding industrial environments including Class 1 Division 2 locations. The 8811-IO-DC-01 mounts on PAC8000 carriers and interfaces to safety system field wiring via dedicated Field Terminals.
Software-Configurable Channels – Each of the 8 channels can be independently configured as an input or output via software, eliminating the need for multiple fixed-function modules and reducing spare parts inventory
SIL 2 Certification without Redundancy – Achieves SIL 2 safety integrity through 1oo1D architecture and comprehensive internal diagnostics, not dependent on “proven in use” data
Hazardous Area Ready – Certified for Class 1 Division 2 and Zone 2 installations with non-arcing inputs and outputs; supports EEx nA nL IIC T4 protection technique
High Output Capacity – Delivers 2 A continuous current per channel, significantly higher than typical safety I/O modules, enabling direct actuation of larger solenoids and contactors
Live Maintenance Capability – Modules can be removed and replaced in hazardous areas without interrupting operation of other node components
Integrated Line Fault Monitoring – Detects open circuit and short circuit conditions on field wiring, reducing troubleshooting time and improving system availability
PAC8000 Ecosystem Compatibility – Fully integrates with PAC8000 controllers, Bus Interface Modules, and Field Terminals for seamless system deployment
8 Configurable Channels – Each channel can be independently set as input or output, providing maximum application flexibility
SIL 2 Safety Certification – Certified for use in safety-related applications up to and including SIL 2 with 1oo1D architecture
Non-Arcing Inputs and Outputs – Designed for safe operation in hazardous areas (Class 1 Division 2 / Zone 2)
High-Current Outputs – Rated up to 2 A continuous per channel, 6 A per module continuous, 8 A for <10 seconds
Comprehensive Input Configuration – Filter time interval (0–8 s), latch enable/polarity, pulse counting (up/down/disable), earth leakage detection
Flexible Output Configuration – Supports pulse, discrete, and pattern output types with pulse width from 1 ms to 60 s
Line Fault Detection – Configurable open circuit and short circuit detection for field wiring
Diagnostic LED Indicators – Module Fault (red), Module Power (green), and Channel Status (yellow) LEDs
Live Maintenance – Hot-swappable in hazardous areas with BFP isolation
Event Logging – Time-stamped data with <200 ms resolution, stored by SafetyNet Controller
HART Compatibility – Supports HART pass-through and acquisition when combined with appropriate HART-capable analog I/O modules
Compact Form Factor – 42 mm width, 210 g weight for space-efficient cabinet installation
Discrete Input Acquisition – Reads ON/OFF states from dry contact switches, proximity detectors, or 24 VDC field devices; threshold current of 0.9 mA typical with 1.2 mA wetting current
Discrete Output Control – Drives actuators, solenoids, alarms, and indicators with up to 2 A continuous per channel; supports pulse, discrete, and pattern output modes
Pulse Counting – Counts input pulses at up to 30 Hz with configurable up-transition, down-transition, or disabled operation
Input Debouncing/Filtering – Programmable filter time from 0 to 8 seconds in 1 ms steps to reject contact bounce and electrical noise
Input Latching – Configurable latch on high or low with enable/disable option for maintaining state until acknowledged
Output Pulse Generation – Generates timed output pulses from 1 ms to 60 seconds duration for momentary actuation applications
Line Fault Detection – Monitors field wiring for open circuit and short circuit conditions; provides diagnostic feedback to the controller
Earth Leakage Detection – Per-channel configurable ON/OFF earth leakage monitoring for enhanced safety
Diagnostic Self-Test – Comprehensive internal diagnostics continuously verify module health; detects faults that would prevent safety function execution
Failsafe Mode Entry – De-energizes all outputs and stops input scanning upon loss of communications or controller指令
Controlled Shutdown – Initiates orderly failsafe transition upon internal fault detection; records diagnostic data for fault determination
Railbus Communication – Interfaces with SafetyNet Controller via internal communication bus for data exchange and configuration
Q1: What is the difference between the 8811-IO-DC and the 8811-IO-DC-01?
A1: The 8811-IO-DC-01 is a specific variant of the 8811-IO-DC module. Both provide 8 configurable channels with SIL 2 certification. The “-01” suffix typically indicates a specific revision or configuration option. Consult the module nameplate or GE documentation for exact variant differences.
Q2: Can the 8811-IO-DC-01 be used in hazardous area installations?
A2: Yes. The 8811-IO-DC-01 is certified for Class 1 Division 2 and Zone 2 hazardous areas with EEx nA nL IIC T4 protection technique. It features non-arcing inputs and outputs for safe operation in potentially explosive atmospheres.
Q3: What is the maximum output current per channel?
A3: Each output channel can deliver up to 2 A continuous current. The module supports 6 A continuous total output current across all channels, with 8 A available for non-continuous operation (<10 seconds).
Q4: How are the channels configured as inputs or outputs?
A4: Each of the 8 channels is independently software-configurable. Configuration is performed through the SafetyNet Controller or PAC8000 engineering tool. The module key code (B6) ensures only compatible Field Terminals can be used.
Q5: What happens if the module detects an internal fault?
A5: If internal diagnostics detect a fault that would prevent the safety function, the module initiates a Controlled Shutdown. All I/O channels are deactivated (inputs not scanned; outputs de-energized) and diagnostic data is recorded. The red Fault LED flashes in Morse code “a” pattern to indicate the fault state.