honeywell experion pks c200 tk prr021 coated redundancy module-0

HONEYWELL

Home >  Products >  HONEYWELL

Honeywell Experion PKS C200 TK-PRR021 Coated Redundancy Module

Honeywell Experion PKS C200 Coated Redundancy Module
Complete Model
TK-PRR021
Official Product Description
Honeywell TK-PRR021 coated redundancy module for Experion PKS C200 redundant chassis-pair configurations.
CORE FEATURE: Coated double-wide redundancy module for matched C200 redundant chassis pairs.
LEAD TIME: In stock
WARRANTY: 1 year
Appurtenance
  • Overview
  • Technical Data
  • Inquiry
  • Electrical Performance
  • Protection & Diagnostics
  • Installation & Wiring
  • Environment & Approvals
  • FAQ
  • Recommend Models
  • Recommended Products
Product Overview
TK-PRR021 is the coated Honeywell redundancy module listed for the Experion PKS C200 control-hardware platform.
Honeywell planning guidance places one double-wide redundancy module in each chassis of a redundant chassis pair. The two partner modules are linked by an approved redundancy cable.
The paired controller chassis must use identical chassis sizes and matching module types in corresponding slot positions. The coated TK prefix distinguishes this version from the non-coated TC model.

Technical Data

Complete model
TK-PRR021
Brand
Honeywell
Product family
Experion PKS C200 control hardware
Product type
Coated redundancy module
Official description
REDUNDANCY MODULE COATED
Module width
Double-wide chassis module
Chassis role
One redundancy module per chassis in a redundant chassis pair
Partner connection
Approved redundancy cable between partner modules
Published cable lengths
1 m, 3 m or 10 m
Placement in 7- or 13-slot chassis
Slots 4 and 5
Placement in 10- or 17-slot chassis
Slots 5 and 6
Coating
Coated version identified by TK prefix
Dimensions
Not specified in the reviewed Honeywell official sources
Weight
Not specified in the reviewed Honeywell official sources
Official sources
Honeywell System HINTS January 2023 page 12; Honeywell Experion Control Hardware Planning Guide R301.1 (EP-DCX), pages 117-127

Inquiry

Electrical Performance

Chassis-pair redundancy
One TK-PRR021 is installed in each member of a matched redundant C200 chassis pair.
Partner communication
The two redundancy modules communicate through the Honeywell redundancy cable between the paired chassis.
Coated hardware
The TK prefix identifies the coated Honeywell version for installations requiring the coated product variant.
Failover architecture
The module is part of the controller-level redundancy arrangement used to support C200 switchover.

Protection & Diagnostics

Redundancy link
Use the Honeywell-approved redundancy cable between partner modules.
Chassis slots
The module occupies two adjacent slots in each redundant chassis.
Configuration matching
Primary and secondary chassis must use identical chassis size and corresponding module placement.
I/O restriction
Honeywell states that I/O modules are not permitted in the redundant controller chassis.
Unused positions
Install blank cover modules in unused chassis slots.
Removal and insertion
Honeywell recommends against removal or insertion under power because it can upset the process.

Installation & Wiring

01 - Verify the exact model
Match TK-PRR021 on the Honeywell label, quotation, packaging and official product list; confirm the coated TK version.
02 - Match the paired chassis
Use identical chassis sizes and matching redundancy-compliant module types in corresponding slots.
03 - Reserve two slots
Place the double-wide module in slots 4 and 5 of a 7- or 13-slot chassis, or slots 5 and 6 of a 10- or 17-slot chassis.
04 - Select the cable length
Choose the approved 1 m, 3 m or 10 m redundancy cable and keep the paired chassis within that distance.
05 - Complete the chassis
Install blank covers in unused positions and verify that controller and CNI placement follows Honeywell planning rules.
06 - Commission redundancy
Validate the paired controller configuration and planned switchover behavior using the applicable Experion release procedures.

Environment & Approvals

Coated construction
The TK model is the coated redundancy-module version.
Chassis environment
Use only within a Honeywell-supported Experion C200 chassis configuration.
Cable planning
Partner chassis spacing must accommodate a 1 m, 3 m or 10 m approved redundancy cable.
Operating temperature
Not specified for this exact model in the reviewed Honeywell official sources.
Storage temperature
Not specified for this exact model in the reviewed Honeywell official sources.
Certifications
No exact-model certification list was identified in the reviewed Honeywell official sources.

FAQ

Q1. How can a quotation for TK-PRR021 be checked against the exact Honeywell model?
Match the complete TK-PRR021 code on the quotation, module label, packaging and Honeywell product list. The official description must identify a coated redundancy module; do not shorten it to TC-PRR021.
Q2. What evidence distinguishes a New TK-PRR021 from Used or Refurbished stock?
Request date-marked photos of the Honeywell label, coating, front face, redundancy-cable connector, chassis edge connector, housing and packaging. Connector wear, coating damage, dust or altered labels can indicate prior service.
Q3. How should a supplier offering TK-PRR021 be validated?
Verify the legal entity, registered address, payment beneficiary and traceable contact. The written offer should state Honeywell, TK-PRR021, coated redundancy module, condition, quantity and warranty.
Q4. Which technical points must engineering confirm before ordering TK-PRR021?
Confirm the C200 redundant-chassis architecture, two-slot placement, identical paired chassis configuration, compatible Experion release and required 1 m, 3 m or 10 m redundancy cable.
Q5. Which physical proof should be requested before payment for TK-PRR021?
Ask for one date-marked photo set showing the full label, coated housing, connector area, chassis edge connector, serial information and sealed packaging, plus the exact redundancy cable if it is included.
Q6. Can TC-PRR021 or another redundancy-module suffix automatically replace TK-PRR021?
No. TC-PRR021 is the non-coated version, while TK-PRR021 is coated. Confirm coating requirement, Experion compatibility, chassis placement and cable arrangement before any substitution.

Recommend Models

34B-AAA-GDFE-1KA
330-120V-300S
7000-17121-2940500
GE DGCC-EHSSABCGXX3XXXX
NVFS3300-5FZ
FBM242 P0916TA
G7S-4A2B-E
VB2-2/2RK
2608D22G04
CAD50BD
PMIN-32FR-0.3M
P0914ZM
A1SX80
7SD5221-5DB99-9HK0/GG
4.4T-10-RSC
3GHZ 1142.8007.03
7000-12761-0000000
PRWT18-8DO-I
ABB AF09-30-10-13
SCLCL103 K2KV01
C320KGS2
AG-80
AN41A
F8576
ABB QHFD122
EVC185 ASTAH040MSS0015H04
705-12P-24D
2907679
BOSS50 PL-5 B01-NN
GE EP-8310-A
9001K36
23D-6112M
IS200TVBAH2A IS200TVBAH2ACC
701N5B3B
GE 673D0515-415-27
082SA415E
5Z966
D9G0123N/PA4001
OCN1-1204C-ARS4
DSA-N2C6X2-12AT
1621-0074-00
140M-C2E-C10
DEV-5
3NSS009811-02
GE 489-P5-LO-A20
BFD71S 765A827G01
FAL34015
ibaPADU-S-CM
B2DX28
3500/53 PWA:133388-01P
231-606/019-000
SL-SW1050
C320KGS21
B&R X20-SYSTEM
700-BR110A1
5SY4514-8
5SY4520-7
B&R X20DI9371
EGGRRLV 0173B4772G001
SS-61522

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000