Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000
siemens 6es7144 1jb31 0xb0 simatic dp et 200x em144 analog input module-0

SIEMENS

Home >  Products >  SIEMENS

Siemens 6ES7144-1JB31-0XB0 ET 200X EM144 Pt100 Analog Input Module

Product Name: SIMATIC DP ET 200X EM144 Analog Input Module
Brand Name: Siemens
Model Number: 6ES7144-1JB31-0XB0
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
Appurtenance:
  • Overview
  • Commercial Term
  • Specifications
  • Contact info
  • Description
  • Function
  • About Company
  • FAQ
  • Other Products
  • Recommended Products
Rugged Two-Channel Pt100 Temperature Acquisition for ET 200X

Siemens 6ES7144-1JB31-0XB0 is an ET 200X EM144 expansion module with two Pt100 analog inputs, channel diagnostics and IP66/67 field protection.

Use the exact Siemens order number 6ES7144-1JB31-0XB0 when matching an installed unit, project or service spare.

Commercial Term

QUOTATION PAYMENT LEAD TIME SHIPPING WARRANTY
Current price and availability
T/T or agreed terms
Confirmed with the quotation
DHL, FedEx, UPS or agreed freight
12 months

Specifications

Technical parameter Value
Product type designation
ET 200X EM144 expansion module
Article number
6ES7144-1JB31-0XB0
Analog inputs
2
Supported sensor
Pt100 resistance thermometer
Sensor connections
2-wire, 3-wire or 4-wire
Resolution
12-bit plus sign
Diagnostics
Wire break and short circuit
Degree of protection
IP66/67
Manufacturer
Siemens

Contact info

Description

Designed for distributed ET 200X stations, 6ES7144-1JB31-0XB0 acquires two Pt100 resistance-temperature signals with 12-bit resolution plus sign. The module supports 2-wire, 3-wire and 4-wire sensor connections for different lead-compensation needs.

The channel diagnostics of 6ES7144-1JB31-0XB0 can distinguish wiring faults from a valid process value when the sensor and module parameters match. IP66/67 performance applies to the completed field assembly, including its seals and approved connections.

Function

Pt100 measurement
Acquire two resistance-temperature signals in an ET 200X station.
Flexible sensor wiring
Use documented 2-wire, 3-wire or 4-wire Pt100 connections.
Channel diagnostics
Identify wire-break and short-circuit conditions for each input.
Field installation
Operate the sealed module assembly with IP66/67 protection.

About Company

SupplyPLCs supports global industrial automation sourcing with exact-model review, product-condition confirmation and responsive quotation service.

Share the complete order number, installed-system context and destination with our team. We will coordinate availability, shipment options and the documentation available for the requested product.

FAQ

Q1. Which sensor wiring method should be selected for 6ES7144-1JB31-0XB0 when lead resistance affects the temperature reading?
Answer: Use the sensor connection configured for the installation: 3-wire or 4-wire arrangements provide lead compensation beyond a basic 2-wire circuit. The channel parameter and physical wiring must match before the reading is accepted.
Q2. Why does 6ES7144-1JB31-0XB0 report a diagnostic fault after a Pt100 sensor is replaced?
Answer: A wire break, short circuit or mismatch between the configured and actual 2/3/4-wire connection can create the fault. Isolate the channel, compare the terminal wiring with the selected measurement method and restore one signal path at a time.
Q3. Can 6ES7144-1JB31-0XB0 be used for a sensor type other than Pt100 without changing hardware?
Answer: No unsupported sensor conversion should be assumed. This module is specified for Pt100 inputs, so use a module and parameter set documented for the required sensor type.
Q4. How should I investigate an unstable reading from 6ES7144-1JB31-0XB0 when no wire-break alarm is active?
Answer: First compare the sensor wiring method with the parameter setting and inspect the lead routing and connections. A valid circuit can still produce a poor measurement when compensation or field wiring is unsuitable.
Q5. When does the IP66/67 rating of 6ES7144-1JB31-0XB0 not protect the installed temperature channel?
Answer: The rating applies to the completed ET 200X assembly. Stop field acceptance if seals, mating surfaces, connectors or cable entries are damaged or left open.
Q6. Which channel information should be captured before sourcing 6ES7144-1JB31-0XB0 for a distributed I/O repair?
Answer: Record the two Pt100 wiring methods, diagnostic messages, ET 200X station position and photographs of the module and connectors. This distinguishes a module fault from a sensor or field-wiring problem.

Other Products

XF830A
SDI-OE-S
NA200T IZMX-RP16A-200
LFI520
4100LR12
SC200-00
SCD2200-RTU PS-22
IC200MDD844F
IC200MDL650L
ABB 1SDH001000R0505-B0821
BS6151 01 SP01
ZBRN2
FGR-002
AMAX-2241
8530D-I
THS710
105S-1
SC42-EP08
AMAX-2241/PMA
ADAP-KOOL
eWONx005CD
CH-LMD1
SP-0108-H2
ABB 2CDG110137R0011
IMD-IM20 / IM20DEMO
Abb 3BSE038226R1
SWH-4200
ABE7 P16T334
81672-01
LP/ 557-180-203

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000