siemens 6gk7343 2ah01 0xa0 simatic s7 300 cp343 2 as interface master-0

SIEMENS

Home >  Products >  SIEMENS

Siemens 6GK7343-2AH01-0XA0 CP343-2 AS-i Master

Product Name: SIMATIC S7-300 CP343-2 AS-Interface Master
Brand Name: Siemens
Model Number: 6GK7343-2AH01-0XA0
Place of Origin: Czech Republic
Warranty: 12 Months
Whatsapp: +86 180 2077 6782
Email: [email protected]

Appurtenance:
  • Overview
  • AS-i Commissioning
  • AS-i Diagnostics
  • Specifications
  • Purchase
  • FAQ
  • Other Products
  • Recommended Products
AS-Interface master communications processor for SIMATIC S7-300 and ET 200M stations
The CP343-2 connects an S7-300 or ET 200M station to an AS-Interface network in accordance with AS-i specification V3.0. The basic version uses the SET key for slave configuration and supports cyclic exchange with standard and A/B slaves without the expanded command interface of the CP343-2P.
AS-i master match: Confirm the complete order number, rack and slot, AS-i slave list and addresses, power supply, cable polarity, operating mode and stored configuration before replacing or migrating the communications processor.

AS-i Commissioning

6GK7343-2AH01-0XA0 is the basic CP343-2 AS-Interface master for S7-300 and ET 200M. It links the backplane bus to an AS-i segment and provides front LEDs and controls for configuration and diagnostic work at the cabinet.
This model is not interchangeable with every CP343-2 family variant. The current slave configuration is accepted with the SET key, while project and program expectations must agree with the AS-i addresses, A/B slave allocation and diagnostic behavior.
Preserve the segment address plan and configuration state before disturbing a working AS-Interface master.
Slave inventory
Export or record every AS-i address, A/B assignment, device type and expected process-data mapping before replacement.
Segment power
Measure the AS-i voltage and polarity at the master and representative slaves and inspect the yellow cable and power-supply arrangement.
SET procedure
Use the SET key only with the intended slave population connected; an incorrect field state can teach an incomplete configuration.

AS-i Diagnostics

Use the master LEDs and slave list to distinguish configuration, addressing and physical-segment faults.
Missing slave
Compare the detected and configured lists, then check slave power, cable penetration, address and duplicate-address conditions.
Config error
Verify that each detected profile and A/B allocation matches the stored configuration before accepting a new field device.
Bus instability
Measure AS-i voltage under load and inspect cable length, repeaters, power supply and intermittent insulation or contact problems.

Specifications

Product type designation
CP343-2 AS-Interface Master
Order number
6GK7343-2AH01-0XA0
Controller platforms
SIMATIC S7-300 and ET 200M
AS-i specification
Version 3.0
Module version
Basic CP343-2
Slave support
Standard and A/B AS-i slaves
Configuration method
SET key and controller project context
Data exchange
Cyclic AS-i process data
Diagnostics
Front status and AS-i diagnostic LEDs
Module width
40 mm
Dimensions
40 x 125 x 120 mm
Net weight
Approximately 0.25 kg

Purchase

Quotation
Current price and availability
Payment
T/T or agreed terms
Lead time
Confirmed with quotation
Shipping
DHL, FedEx, UPS or agreed freight
Warranty
12 months

FAQ

Q1
How should an engineer confirm that 6GK7343-2AH01-0XA0 is the correct CP343-2 variant for the station?
Match the full label and confirm that the application uses the basic CP343-2 for S7-300 or ET 200M, not the expanded CP343-2P command interface. Compare rack slot, STEP 7 hardware configuration and AS-i slave plan.
Q2
What should be recorded before replacing 6GK7343-2AH01-0XA0 on an active AS-i segment?
Record all slave addresses, A/B assignments, device profiles and process-data mapping. Save the controller project, photograph the front LEDs and terminals, and measure AS-i voltage before the segment is powered down.
Q3
Why can 6GK7343-2AH01-0XA0 show a configuration error after a new slave is connected?
The detected slave address or profile may not match the stored configuration, or two slaves may share an address. Compare detected and configured lists, correct addressing and use the SET procedure only when the intended slave population is present.
Q4
How should maintenance diagnose a slave that intermittently disappears from 6GK7343-2AH01-0XA0?
Check AS-i voltage at the master and affected slave under load, inspect cable penetration and connectors, and look for duplicate addresses. Correlate the dropout with vibration, load switching and the master diagnostic display before replacing the processor.
Q5
Can 6GK7343-2AH01-0XA0 be replaced by the current AS-i master without project changes?
A migration requires engineering review because the successor platform, hardware catalog, data mapping and diagnostic interface differ. Preserve the original project and slave plan, then test address handling and PLC logic on the selected successor.
Q6
What precautions are required when using the SET key on 6GK7343-2AH01-0XA0?
First verify that every intended slave is powered and correctly addressed and that no temporary or faulty device is connected. Accepting the field state with an incomplete segment can create a configuration that masks the original fault.

Other Products

POL95U.00
002640
KS40 - 9404 406 40991
110063001 2RP
PM5300 METSEPM5320
POL635.00
3113A
107-MX
140 CPU 113 02
1SAP450000R0001 AO523
CU351O 100-240V9
PXM20
440R-G23216 MSR142RTP
EY200
ENCL-MZ800-PAN
295619-003
PDT 3100 / STBPDT3100
IQE35-1201U80035
6590 COMP-Y/C
MMX-400 / MMX-1 300
LV540003 CVS400F
CMD5B9102
LNL-1320
WRT-822B
S-532-0 s UNC532
P8-HDMI2-4KDS
GX-7
LBB4442/00
BSAP-2035 17000949F1
M8CS 2C13793G06

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000