The ICU24 plugs into the assigned TM-ICU15 terminal module.
Product Name: ICU24 Control Unit
Brand Name: Siemens
Model Number: 6SL3244-0SA00-1AA0
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
Email: [email protected]
| Minimum Order Quantity | 1 Piece |
|---|---|
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3-7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
| Model Number | 6SL3244-0SA00-1AA0 |
|---|---|
| Product Family | SINAMICS ET 200S FC |
| Product Type | ICU24 control unit |
| Assigned Terminal Module | TM-ICU15 |
| Terminal Module Order Number | 3RK1903-3EA10 |
| Distributed I/O Platform | SIMATIC ET 200S |
| SIMOTION Function Block | _ET200S_FC_control |
| Command Data Set 1 | Activation supported |
| Command Data Set 2 | Activation supported |
| Motor Start | Specified-speed command supported |
| Motor Stop | Supported |
| Addressing Requirement | Required before SIMOTION control |
6SL3244-0SA00-1AA0 is the Siemens ICU24 control unit for the SINAMICS ET 200S FC distributed frequency-converter system. Siemens assigns it to the TM-ICU15 terminal module, order number 3RK1903-3EA10. The control unit can be addressed by SIMOTION through the documented _ET200S_FC_control function block. That interface supports parameter reading and writing, command-data-set selection, drive-error reset and motor start or stop commands. Correct ET 200S FC addressing is required before control communication is commissioned.
6SL3244-0SA00-1AA0 places frequency-converter control inside the modular ET 200S station, reducing the need for a separate centralized drive enclosure. It is suited to distributed conveyor, handling and machine-axis applications that require drive commands close to the field I/O. The terminal module provides the replaceable connection base for the active control unit. Existing addressing, motor data and drive parameterization must be captured before replacement. Commissioning should follow the ET 200S FC operating instructions for the complete converter assembly.
The ICU24 plugs into the assigned TM-ICU15 terminal module.
Documented functions include drive-parameter reading and writing.
Two command data sets can be selected through the control workflow.
Use TM-ICU15, order number 3RK1903-3EA10, with the ICU24.
Complete the ET 200S FC addressing before SIMOTION function-block control.
Retain the commissioned motor and converter parameters before exchange.
Use the documented drive-error reset only after the fault cause is checked.
Siemens assigns the ICU24 to TM-ICU15, order number 3RK1903-3EA10.
The documented _ET200S_FC_control function block provides the supported command and parameter interface.
Yes. The Siemens function description includes activation of command data sets 1 and 2.
Record addressing, motor data, converter parameters and the installed terminal-module arrangement.
The complete Siemens reference is checked against the supplied unit before packing.
The quotation records the final dispatch timing after payment and stock confirmation.