siemens 6sl3352 6tg41 3aa3 sinamics s replacement control interface board-0

SIEMENS

Home >  Products >  SIEMENS

Siemens 6SL3352-6TG41-3AA3 SINAMICS S Replacement Control Interface Board

Product Name: SINAMICS S Replacement Control Interface Board
Brand Name: Siemens
Model Number: 6SL3352-6TG41-3AA3
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
Appurtenance:
  • Overview
  • Retrofit Mapping
  • Description
  • Commissioning
  • Specifications
  • Commercial Term
  • Contact info
  • FAQ
  • Other Products
  • Recommended Products
Replacement control interface board for a 500–690 V, 1270 A SINAMICS motor module
Siemens identifies 6SL3352-6TG41-3AA3 as a spare control interface board for a 500–690 V AC, 50/60 Hz, 1270 A motor module. The product is discontinued, and the official service mapping assigns a CIM and power-unit-dependent IPD card for migration.
Before you order: Confirm the exact 1270 A motor-module article, voltage class, cooling and power-unit version, board revision, connector map and Siemens service mapping before purchase or migration.

Retrofit Mapping

The old CIB is replaced as part of a coordinated CIM and IPD arrangement selected for the exact power unit.
CIB identity
Confirm the installed label is exactly 6SL3352-6TG41-3AA3 and record the board revision and motor-module nameplate.
CIM mapping
The official service table assigns CIM 6SL3350-6TK00-0EA0 for this old control electronic board.
IPD mapping
The same table assigns power-unit-dependent IPD card 6SL3352-3AG41-3AB0; verify the complete pair before ordering.

Description

6SL3352-6TG41-3AA3 is an old control electronic board in the SINAMICS S chassis-drive family. The Siemens service document maps this CIB to CIM 6SL3350-6TK00-0EA0 and IPD card 6SL3352-3AG41-3AB0.
That mapping is not permission to change one board in isolation. Record the complete motor-module nameplate, installed CIB and adjacent power-unit hardware, then follow the Siemens retrofit procedure for the matched CIM and IPD combination.

Commissioning

High-power drive work requires safe isolation, controlled connector handling and a staged functional test.
Isolation
Lock out the drive, verify the DC link is discharged and follow the Siemens chassis-drive service procedure and ESD precautions.
Wiring record
Photograph and label control, feedback and firing-related connections before removal; inspect connector condition and protective earth.
Functional test
Review all drive diagnostics, verify the 1270 A motor-module identification and test the affected stage at an approved low-risk operating point.

Specifications

Product type designation SINAMICS S replacement control interface board
Order number 6SL3352-6TG41-3AA3
Installed section Motor Module
Voltage class 500 to 690 V AC
Line frequency 50/60 Hz
Current class 1270 A
Lifecycle status Discontinued spare part
Published net weight 0.4 kg
Official replacement CIM 6SL3350-6TK00-0EA0
Official replacement IPD 6SL3352-3AG41-3AB0
Migration basis Power-unit-dependent Siemens mapping
Service requirement Matched hardware, wiring and controlled test

Commercial Term

Quotation
Current price and availability
Payment
T/T or agreed terms
Lead time
Confirmed with quotation
Shipping
DHL, FedEx, UPS or agreed freight
Warranty
12 months

Contact info

FAQ

Q1
Can 6SL3352-6TG41-3AA3 be installed in any 500–690 V SINAMICS S motor module?
No. It is identified for the 1270 A motor-module class, and the power-unit version and board revision must match. Confirm the full motor-module nameplate and Siemens service mapping before ordering.
Q2
What official migration parts correspond to 6SL3352-6TG41-3AA3?
The Siemens service table maps the old CIB to CIM 6SL3350-6TK00-0EA0 and IPD card 6SL3352-3AG41-3AB0. Treat them as a matched retrofit set for the documented power unit, not as independent generic substitutes.
Q3
Why is replacing only 6SL3352-6TG41-3AA3 risky when the original board is discontinued?
The old CIB combines functions that Siemens later separates into a common CIM and a power-unit-dependent IPD card. Mixing an unmatched board, IPD or power unit can leave the drive uncommissionable or expose the power stage to incorrect control.
Q4
What must be recorded before removing 6SL3352-6TG41-3AA3 from a running drive?
Record the motor-module article, voltage and 1270 A class, CIB revision, adjacent power-unit hardware, connector locations, protective earth, cable routing and the complete drive configuration and alarm history.
Q5
What should be checked if the drive reports power-stage or feedback faults after 6SL3352-6TG41-3AA3 service?
Keep the drive isolated until the exact CIM/IPD mapping, connector seating, cable routing and protective-earth connections are confirmed. Compare the first diagnostic events with the pre-service record before attempting repeated resets.
Q6
How should 6SL3352-6TG41-3AA3 be functionally accepted after replacement or retrofit?
After safe isolation and installation checks, verify that the drive recognizes the matched hardware, review all active diagnostics and test enable, feedback and controlled motor response at an approved low-risk operating point before applying production load.

Other Products

LNL-MT11-485
ABB 1VCF339750R1912
VSRPT-IDOOR-72
6EP1332-4BA00
KJ3001X1-CA1
MT11
6010P
RPS1300 6GK6000-8HS01-0AA0
LBB1856/00 LBB1957/00
BE103194 A62-AC143
ULXS4 784-820MHz-R4
330930-045-02-00
SSB401-53
NPT-8R0-0108-1
033100-A
305228-PR
370710B-200
402712-PR
BA21747-040-00
SA6200A-201
750-841 3x750-432 3x 750-531 750-600
998-1105-016
9274CBTE-0010
DS10 LV CEAS410751-01-01 / HK50AA003
F9342LP-05
HMIDT551
MNL-13R MNL-13RF3
A5E00247018
SB401-13
42716625-V1

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000