Exact configuration
The module supports cyclic and acyclic measured values, fixed measured-value sets and reparameterization during RUN.
|
Primary engineering value
A 50 ms measurement cycle and integrated process-image data support energy transparency and electrical monitoring without a separate external meter interface.
|
|
Complete model
|
6ES7134-6PA01-0BD0
|
|
Product family
|
SIMATIC ET 200SP
|
|
Product type
|
AI Energy Meter 400VAC ST analog input module
|
|
Firmware version
|
V3.0
|
|
Usable BaseUnit
|
BU type D0, BU20-P12+A0+0B
|
|
Measured variables
|
Voltage, current, active/reactive/apparent power, energy, frequency, power factor and phase angle
|
|
Input voltage
|
100 to 240 V AC; permissible range 90 to 264 V
|
|
Frequency range
|
47 to 63 Hz
|
|
Power loss
|
0.6 W typical
|
|
Process image
|
44 bytes total; 32 input and 12 output bytes
|
|
Cycle time
|
50 ms
|
|
Accuracy class
|
Voltage 0.5; current 0.5; active/apparent/reactive power 1; active energy 1; reactive energy 2
|
|
Isolation test
|
2,300 V AC for 1 minute; CAT III potential separation 3,700 V AC
|
|
Dimensions
|
20 x 73 x 58 mm (W x H x D)
|
|
Weight
|
Approximately 45 g
|
|
Machine energy monitoring
Measure electrical consumption and power values for machine sections directly in the distributed I/O station.
|
|
Plant transparency
Acquire active and reactive energy, power factor and frequency for operational dashboards and diagnostics.
|
|
Load supervision
Use voltage and current values to identify abnormal loading or supply conditions within engineered limits.
|
|
Maintenance data
Use acyclic access and parameterization in RUN to support commissioning and service workflows.
|
|
Voltage channels
Three voltage channels measure directly from the monitored AC system within the stated input range.
|
|
Current measurement
Phase currents are measured with external current transformers according to the selected configuration.
|
|
Process image
The module exchanges 32 input bytes and 12 output bytes with the ET 200SP station.
|
|
Measurement sets
Fixed cyclic measured-value sets and additional acyclic values provide flexible access to electrical data.
|
|
BaseUnit
Use the specified D0 BaseUnit configuration and verify terminal assignment before wiring.
|
|
Transformer selection
Select compatible current transformers and configure the correct transformation ratios.
|
|
Parameterization
Set network type, measurement range and diagnostic behavior in the compatible engineering environment.
|
|
Commissioning
Validate phase sequence, voltage inputs, current-transformer polarity and plausibility of measured power.
|
|
Mounting envelope
Allow 20 mm width, 73 mm height and 58 mm depth; approximate weight is 45 g.
|
|
Supply
The module is supplied through voltage channel L1 from a 100 to 240 V AC system within 90 to 264 V.
|
|
Electrical safety
Observe CAT III separation, 2,300 V AC test level and all ET 200SP wiring and isolation rules.
|
|
Installation
Any mounting position is permitted when the system-level environmental and spacing requirements are met.
|
|
KL2001X1-BB1
|
EJA120A-EES
|
IMDSM04
|
|
SE3008
|
KJ2006X1-BM1
|
5X00481G01
|
|
KJ1611X1-BA1
|
OCR1100
|
SPHSS0
|
|
369B1842G5005
|
KJ2201X1-BA1
|
FP20-6TX2TX
|
|
PR6424/000-030
|
VE3007
|
369B1852G0007
|
|
6ES7422-1BL00
|
5X00226G02
|
CE3006
|
|
CE4003S2B10
|
5X00481G04/5X00226G04
|
1X01046H01L
|
|
5X00790G01
|
1C31125G01
|
MAI5
|
|
KL2101X1
|
MLP50
|
SPBRC400
|
|
KJ3243X1-BB2
|
KJ4001X1-CC1
|
SPCIS22
|
|
369B1841G5006
|
IMICT13A
|
EJA110E-DMS
|
|
KC3020X1-BA1
|
KL4503X1-FA2
|
KJ2006X1-BK1
|
|
5X00453G01
|
KJ2221X1-EA1
|
NTDI21-A
|
|
3051S2CD0A
|
1C31113G05
|
SPHSS13
|
|
PR6423/002-131
|
EJA530E-JCS4N-017DL
|
1C31189G03
|
|
5X00301G01
|
5X00502G01
|
SS4307T01
|
|
5X00419G01
|
5X00226G03
|
1C31194G01/1C3119
|
|
SPDSI22
|
DPU55
|
KC4011X1-BP1
|
|
1C31238H
|
SE4604T04
|
KL3302X1-BA1
|
|
1C31197G01
|
IMHSS03
|
BRC410SPBRC410
|