siemens simatic s7 1200 6es7231 5pd32 0xb0 sm 1231 rtd input module original new-0

SIMATIC S7 Series

Home >  Products >  SIEMENS >  SIMATIC S7 Series

Siemens SIMATIC S7-1200 6ES7231-5PD32-0XB0 SM 1231 RTD Input Module | Original New

SIEMENS | SIMATIC S7-1200
6ES7231-5PD32-0XB0
SM 1231 RTD Analog Input Module
4 RTD or resistance inputs | 2-, 3- or 4-wire connection | 0.1 degree resolution
LEAD TIME: In stock
WARRANTY: 1 year
Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • Applications
  • Electrical
  • Installation
  • Compliance
  • FAQ
  • Recommend Models
  • Recommended Products
Siemens 6ES7231-5PD32-0XB0
The 6ES7231-5PD32-0XB0 is a SIMATIC S7-1200 SM 1231 RTD signal module with four analog inputs for resistance thermometers and resistance measurement. It supports 2-, 3- and 4-wire connection and provides 0.1 degree temperature resolution or 15 bit plus sign resistance resolution.
Core value: four-channel precision RTD and resistance acquisition with flexible sensor wiring for SIMATIC S7-1200.

Technical Data

OFFICIAL SPECIFICATIONS | 6ES7231-5PD32-0XB0
Complete model
6ES7231-5PD32-0XB0
Product family
SIMATIC S7-1200
Product type
SM 1231 RTD analog input signal module
Dimensions
45 x 100 x 75 mm (W x H x D)
Weight
220 g
Analog inputs
4 channels
Measurement principle
Integrating RTD and resistance measurement
Supported sensors
Resistance thermometers and resistors
Sensor connection
2-wire, 3-wire or 4-wire
Temperature resolution
0.1 C or 0.1 F
Resistance resolution
15 bit plus sign
Supply voltage range
20.4 to 28.8 V DC
24 V DC current consumption
40 mA
SM bus current consumption
80 mA
Power dissipation
1.5 W
Maximum input withstand
+/-35 V
Input impedance
At least 10 Mohm
Noise rejection
85 dB at the selected 10, 50, 60 or 400 Hz integration frequency
Common-mode rejection
Greater than 120 dB
Electrical isolation
707 V DC field-to-logic type test; no channel-to-channel isolation
Repeatability
+/-0.05% of full scale
Sensor dissipation
0.5 mW
Signal cable and lead resistance
100 m maximum; 20 ohm maximum lead resistance, or 2.7 ohm for 10 ohm RTD
Operating temperature
-20 to +60 C horizontal mounting; -20 to +50 C vertical mounting
Protection, diagnostics and approvals
IP20; overflow, underflow, wire-break and low-24 V diagnostics; CE, UL, CSA, FM, RCM and KC approvals; RoHS compliant

Applications

RTD temperature
Acquires four resistance-temperature channels with 0.1 degree resolution.
Resistance measurement
Measures supported resistance ranges with 15 bit plus sign resolution.
Flexible field wiring
Supports 2-, 3- and 4-wire sensor circuits for installation-specific accuracy needs.
S7-1200 expansion
Adds dedicated temperature and resistance channels to a compatible SIMATIC S7-1200 station.

Electrical

Input channels
4 RTD or resistance inputs
Connection methods
2-wire, 3-wire and 4-wire
Resolution
0.1 C or 0.1 F; resistance 15 bit plus sign
Supply
20.4 to 28.8 V DC
Current consumption
40 mA from 24 V DC; 80 mA from SM bus
Input impedance
At least 10 Mohm
Noise rejection
85 dB at selected 10, 50, 60 or 400 Hz integration frequency
Repeatability
+/-0.05% of full scale
Isolation
707 V DC field-to-logic type test; channels are not mutually isolated

Installation

1 | Mount the RTD module
Install the 45 mm wide signal module in the permitted S7-1200 station position and observe the mounting-orientation temperature limit.
2 | Select the sensor and wiring mode
Configure the exact RTD or resistor type and use the corresponding 2-, 3- or 4-wire terminal arrangement on X10 through X13.
3 | Control lead resistance
Keep signal cable within 100 m and total lead resistance within 20 ohm, or 2.7 ohm when using a 10 ohm RTD.
4 | Verify diagnostics and scaling
Check wire-break, overflow, underflow and low-supply diagnostics before commissioning each channel.

Compliance

Enclosure protection
IP20; install inside a suitable control enclosure.
Operating environment
-20 to +60 C horizontally mounted or -20 to +50 C vertically mounted.
Approvals
CE, UL, CSA, FM, RCM and KC approvals listed for the module family.
Materials
RoHS-compliant SIMATIC S7-1200 signal module.
Use only documented RTD or resistor types, wiring methods and lead-resistance limits; install the module in an enclosure and verify diagnostics before commissioning.

FAQ

Q1. How can a buyer verify the exact 6ES7231-5PD32-0XB0?
A. Match the complete Siemens MLFB on the module and packaging. The 5PD32 code identifies the four-channel SM 1231 RTD module; it is different from voltage/current, thermocouple and other RTD channel-count variants.
Q2. How can New, Used and Refurbished condition be distinguished?
A. Request current photos of the front label, MLFB label, X10 through X13 terminals, housing latches and packaging. A new module should show no terminal marks, rail-latch wear, sensor-wire residue, contamination or replacement labels.
Q3. How should procurement verify the supplier?
A. Check the legal entity, registration, verifiable address, company-domain correspondence, bank-beneficiary consistency and traceability for the exact 6ES7231-5PD32-0XB0 before payment.
Q4. Which technical points should an engineer confirm?
A. Confirm four RTD/resistance inputs, supported sensor type, 2-, 3- or 4-wire method, 0.1 degree resolution, 20.4 to 28.8 V DC supply, lead-resistance limit, 45 x 100 x 75 mm size and 220 g weight.
Q5. What physical evidence should be requested before payment?
A. Ask for dated photos or video showing the full MLFB, serial and hardware markings, terminal condition, packaging labels and dimensions. If testing is offered, request a serial-numbered live RTD reading and wire-break diagnostic demonstration.
Q6. Can another SM 1231 suffix replace this RTD module?
A. Not automatically. Different suffixes change signal type, channel count, terminal assignment, accuracy and diagnostics. A voltage/current or thermocouple module cannot replace this RTD version without a full wiring and program review.

Recommend Models

60 INDUSTRIAL MODELS
MT52340DB LF 52345DB
TM221C24T
3900-02-10 RTD PT100
KNX 2CDG 110 085 R0011
700476021
F124x04 07400030
DBA-EA43/A10RH
CSD-SA1E1-1
NC-540-1-1-5
181B0729 SPR-CMB21640
8440-1041
ABB TU516/1SAP212000R0001
QPL25.500
MBC-130 / MBC-130B-F000
X100 X100A
ABB SA/S 8.6.1.1 2CDG 110 153 R0011
LP/ 557-180-203
H4D1F1X
Rex2000 D42
IS-UNITY
2CDG110 064 R0011
EC401-10
ULXP4 784-820
51453540.001
GDP-CBL-OBD/ETH-01
IR125Y-2 B91023013
ABB 3F 16/20A REG EM/S3.16.1 2CDG110148R0011
FET-40G 10-2920-02
XFR822A XS821-22
PH101 ID36048/11
MACX MCR-EX-SL-RTD-I-NC
CPM04-BN / BN
DDM-163
1609C42G-01
500-003087-TK0
6ES7222-1BF32-0XB0
760-3
AV3135 00-1A-07-06-C2-FB
DPS-750XB E98791-011
DIN 190608
KFD2-EB2.R4A.B
750-841 3x750-432 3x750-531 750-600
CS510
HV2855461
IQ4/IO/8DO IQ4IO-5000U000080
11028-00
HACH 6200900
CE96T14A2
V1405-24
7000005-679
XPR-A ST/N/04
UNO-PS/1AC/24DC/100W
E50 48503010
CCHE-CP12-6C-P003RH
EASY-E4-UC-12RC1
KRP928BB2S
SR2E201BD
FP02-77A/fp02/S0A/M/32/NC/S/77A-24D/35
MH4885PWHIC
6GK5744-1ST00-2AB6

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000