Product Name: industrial security module
Brand Name: Siemens
Model Number: 6GK5612-0BA00-2AA3
Place of Origin: See supplied nameplate
Warranty: 12 Months
Whatsapp: +86 18020776782
Email: [email protected]
Engineering brief
Siemens 6GK5612-0BA00-2AA3 is a SCALANCE S612 security module for separating industrial Ethernet zones. Its two 10/100 Mbit/s RJ45 ports support firewall and VPN functions at the cell boundary.
Deploy 6GK5612-0BA00-2AA3 with a documented network plan: identify both port zones, allowed application traffic, VPN peers and administrator access. Check the 24 V supply and 0–60 °C operating range against the cabinet environment.
Before replacing 6GK5612-0BA00-2AA3, export the security configuration and certificates. Siemens lists 6GK5612-0BA10-2AA3 as successor; validate rule and VPN migration before substitution.
Map each required PLC, HMI and engineering flow through the security boundary. Keep a backup of firewall rules and peer certificates.
Record peer addresses, device time and certificates. A working Ethernet link does not prove authentication or application access.
Measure 24 V at the device under load; permitted input is 18–32 V. Keep within 0–60 °C and 95% RH without condensation.
Use the documented rail or wall mount. Siemens requires a suitable IP54 enclosure for Zone 2 installations.
Check the application port, source and destination addresses, firewall rule order and port direction. ICMP reachability does not prove that cyclic or engineering traffic is allowed.
Export rules, VPN peer settings, certificates and administrative access data. Record firmware and port wiring, then test every critical protocol after restore.
Siemens lists it as successor, but confirm configuration migration and firmware support. Test firewall behavior, certificates, VPN establishment and critical control paths.
Compare peer addresses, certificates, device clocks and authentication settings. Check the upstream path for VPN traffic, then read diagnostics before changing keys.
Keep terminal voltage within 18–32 V, ambient within 0–60 °C and prevent condensation. IP30 needs an appropriate cabinet in harsher locations.
Test every approved PLC/HMI flow plus one intentionally blocked flow against the traffic matrix, and retain a rollback configuration.
| AMF9 | EA-AMP-SUB-1D-500R | BM12 616-661 |
| MW1-LTX-F4 | PXI-5610 | BS6151 01 SP01 |
| 330930-045-02-00 | UME-512A | ML350 801233-B21 E5-2609v4 |
| S-2-TCPUSE-H-Di6 | FSL-751 | C005-M-E2 |
| 1756-CNBR/E PN:14151 | FR78B-400230 | 000435 |
| 51303932-476-RP | SB401-13 | 242171-A |
| IC200CHS022K | 23001-069 | E3003-61058 |
| HMIDT551 | HMIS85 | BA21747-040-00 |
| F/E000000000005ER1301111 | 6AV3688-3EH47-0AX0 | DM-RMC-100 |
| F0.95 | 6804W | 2CDG 120 044 R0011 |