ABB AC500-eCo S500-eCo
AO561
2-Channel Analog Output Module
2 configurable AO | -10 to +10 V, 0 to 20 mA, 4 to 20 mA | 12 bits including sign, 13 bits for E0 or later | Order code 1TNE968902R1201
LEAD TIME: In stock | WARRANTY: 1 year
|
|
OFFICIAL PRODUCT DATA
Technical Data
ABB hardware manual 3ADR010121, revision 26
|
|
Complete model
|
AO561
|
|
Brand
|
ABB
|
|
Product family
|
AC500-eCo / S500-eCo
|
|
Product type
|
2-channel analog output module
|
|
Order code
|
1TNE968902R1201
|
|
Analog outputs
|
2 configurable voltage or current channels in one group
|
|
Output ranges
|
-10 to +10 V; 0 to 20 mA; 4 to 20 mA
|
|
Resolution
|
12 bits including sign; 13 bits including sign for version E0 or later
|
|
Process voltage
|
24 V DC
|
|
Current consumption
|
Approx. 5 mA from CPU or interface supply; 0.1 A plus output load, or 0.01 A plus load for version E0 or later
|
|
Voltage output load
|
Maximum 2 mA
|
|
Current output load
|
0 to 500 ohm
|
|
Accuracy at 25 deg C
|
Typical +/-0.5% full scale for voltage and 0 to 20 mA; +/-0.7% for 4 to 20 mA
|
|
Isolation
|
No channel-to-channel, I/O-bus or process-supply galvanic isolation
|
|
Cable length
|
Maximum 100 m shielded with conductor cross section greater than 0.14 mm2
|
|
Terminal block
|
TA563-11, TA564-11 or TA565-11
|
|
Mounting
|
DIN rail or wall mounting; horizontal or vertical
|
|
Dimensions
|
34 x 135 x 84.2 mm maximum width x height x depth
|
|
Weight
|
Approx. 120 g
|
|
Lifecycle
|
Active
|
|
DIRECT CONTACT
Inquiry
Product-specific inquiry for AO561
|
|
APPLICATION PROFILE
Applications
Supported use cases for AO561
|
|
Voltage control
|
Configure either channel for -10 to +10 V bipolar actuator or drive setpoints.
|
|
Current loops
|
Configure either channel for 0 to 20 mA or 4 to 20 mA unipolar output.
|
|
Independent configuration
|
Choose voltage or current mode separately for each of the two channels.
|
|
Compact expansion
|
Add two analog outputs to an S500-eCo station in a 34 mm wide module.
|
|
SIGNAL AND CHANNEL BEHAVIOR
Measurement
Configuration and conversion characteristics for AO561
|
|
Channel group
|
Both outputs form one two-channel group but are configured individually.
|
|
Resolution
|
Standard versions provide 12 bits including sign; version E0 or later provides 13 bits including sign.
|
|
Load limits
|
Current outputs support 0 to 500 ohm; voltage outputs supply a maximum 2 mA.
|
|
Accuracy
|
At 25 deg C, typical error is +/-0.5% full scale for voltage and 0 to 20 mA, or +/-0.7% for 4 to 20 mA.
|
|
MOUNTING AND WIRING
Installation
Installation requirements for AO561
|
|
Terminal blocks
|
Use an 11-pin TA563-11, TA564-11 or TA565-11 block according to screw/spring and cable-entry preference.
|
|
Supply
|
Provide 24 V DC process voltage and the recommended external fuse.
|
|
Wiring
|
Use shielded analog cable up to 100 m and keep current-loop resistance within 500 ohm.
|
|
Mounting envelope
|
Allow 34 mm width, 135 mm height and 84.2 mm maximum depth with unobstructed natural convection.
|
|
CHANNEL SUPERVISION
Diagnostics
Status indication and protective behavior for AO561
|
|
Module LEDs
|
Green PWR indicates process voltage and red ERR reports module or channel errors.
|
|
Channel supervision
|
The module reports overflow, underflow, current wire break and voltage short circuit through I/O-bus diagnostics.
|
|
Output protection
|
Voltage outputs are short-circuit protected and current outputs are protected against reverse current.
|
|
Parameter setup
|
Channel mode and range are transferred from the CPU or communication-interface master during power-up.
|
|
PROCUREMENT AND ENGINEERING CHECKS
FAQ
Six questions specific to ABB AO561 and order code 1TNE968902R1201
|
|
RANDOM MIXED-BRAND SELECTION
Recommend Models
Independent 60-model selection for AO561
|
|
SE4003S2B11
|
DSI14
|
1C31224G01/1C31227G01
|
|
VE4017P0
|
5X00062G01
|
KJ4001X1-CE1
|
|
1C31122G01
|
SPDSI14
|
MAG5000
|
|
KJ3102X1-BE1
|
A6500-CC
|
SPIIT1
|
|
1C31234G01
|
OCR1100
|
SE4603T05
|
|
DSQC-328
|
VE4022
|
1C31167G01
|
|
SE4306T01
|
IMSI23
|
V18345-101521001
|
|
KJ3201X1-BA1
|
5X00062G
|
SPDSI22
|
|
530E-JBS4N-017DL
|
TRBU1065G-100
|
PR6423/00R-010
|
|
IEPAS02ABB
|
SPTPS13
|
KJ2005X1-BA2
|
|
KC4011X1-BP1
|
VE3007
|
KJ3206X1-BA2
|
|
KJ3206X1-BA1
|
5X00167G01/1X00188H01
|
3051CG5A02A
|
|
1C31223G01
|
SE4017P0
|
5X00062G01/5X00063G01
|
|
IIT13
|
5X00226G01
|
EJA120A-EES
|
|
1B30035H01
|
SED01
|
PHARPS32200000
|
|
2SY7010-1LB14
|
A6370D
|
KJ2005X1-MQ1
|
|
SPBRC400
|
KJ4110X1-BA1
|
SE4026
|
|
KL2001X1-BD1
|
SPFEC12
|
2SY5010-1LB04
|
|
V18345-302712000ZZ
|
5X00226
|
6DR5210-0EN00-0AA0
|
|
1X01046H01L
|
EJA110E-JHS5J
|
SS4301T02
|