allen bradley controllogix 1756 1756 oa16 16 point 74 265 vac output module-0

ROCKWELL

Home >  Products >  ROCKWELL

Allen-Bradley ControlLogix 1756 1756-OA16 16-Point 74-265 VAC Output Module | Original New

Allen-Bradley ControlLogix 1756 16-Point 74-265 VAC Output Module
Complete Model
1756-OA16
Official Product Description
ControlLogix AC digital output module with 16 mechanically fused outputs in two groups, a 74-265 VAC operating range and 0.5 A maximum per point.
CORE FEATURE: Sixteen 74-265 VAC outputs arranged as two mechanically fused eight-point groups with group fuse diagnostics.
LEAD TIME: In stock
WARRANTY: 1 year
Appurtenance:
  • Overview
  • Technical Data
  • Inquiry
  • Features
  • Wiring
  • Installation
  • Environment
  • FAQ
  • Recommend Models
  • Recommended Products
Product Overview
1756-OA16 is an Allen-Bradley ControlLogix 1756 AC digital output module for chassis-based industrial control systems.
Rockwell Automation specifies 16 outputs in two groups of eight, a 120/240 VAC 50/60 Hz category and a 74-265 VAC operating range.
The module includes one mechanical fuse and fuse indicator per group, diagnostic time stamping and a 20-pin removable terminal block interface.

Technical Data

Complete model
1756-OA16
Brand
Allen-Bradley / Rockwell Automation
Product family
ControlLogix 1756
Product type
AC digital output module
Outputs
16 mechanically fused outputs, 8 points per group
Voltage category
120/240 VAC, 50/60 Hz
Operating voltage range
74-265 VAC at 47-63 Hz
Pilot duty
0.5 A
Output delay
9.3 ms at 60 Hz; 11 ms at 50 Hz, off-to-on and on-to-off
Current draw at 5.1 V
400 mA
Current draw at 24 V
2 mA
Total backplane power
2.1 W
Power dissipation
6.5 W maximum at 60 degrees C
Off-state leakage current
3 mA maximum per point
On-state voltage drop
1.5 V at 0.5 A; 5.7 V for load current below 50 mA
Current capacity
0.5 A per point, 2 A per group and 4 A per module at 60 degrees C
Minimum load
10 mA per point
Surge current
5 A for 43 ms per point; 15 A for 43 ms per group, repeatable every 2 seconds at 60 degrees C
Diagnostics
One fuse and indicator per group; +/-1 ms diagnostic time stamp
Removable terminal block
1756-TBNH or 1756-TBSH, ordered separately
Dimensions
144.5 x 34.6 x 146.9 mm, height x width x depth
Weight
Approximately 0.2 kg (0.5 lb)
Slot width
One ControlLogix chassis slot
Enclosure type
None, open-style equipment
Operating temperature
0 to 60 degrees C
Storage temperature
-40 to +85 degrees C
Relative humidity
5 to 95 percent, noncondensing
Lifecycle
Active
Official sources
Rockwell Automation product page; publication 1756-TD002T-EN-E pages 35-37; official drawing ABIOM091; Rockwell ControlLogix 1756 system reference

Inquiry

Features

Sixteen AC outputs
Two groups of eight outputs support 120/240 VAC industrial loads within the 74-265 VAC operating range.
Group fusing
Each eight-point group has one mechanical fuse and a dedicated fuse indicator.
Published surge capacity
The module supports the specified 43 ms point and group surge currents for controlled AC load switching.
Diagnostic timing
Fuse diagnostics carry a published time-stamp accuracy of +/-1 ms.

Wiring

Field wiring
Use a 1756-TBNH or 1756-TBSH 20-pin removable terminal block housing; order the RTB separately.
Output group 0
Connect OUT-0 through OUT-7 with the L1-0 and L2-0 group supply terminals according to the official diagram.
Output group 1
Connect OUT-8 through OUT-15 with the L1-1 and L2-1 group supply terminals according to the official diagram.
Backplane
The module draws 400 mA at 5.1 V and 2 mA at 24 V from the ControlLogix backplane.

Installation

01 - Verify the complete catalog number
Match 1756-OA16 on the quotation, module label, packaging and Rockwell Automation product record.
02 - Confirm load compatibility
Verify 74-265 VAC at 47-63 Hz, minimum 10 mA load and the point, group and module current limits.
03 - Select the RTB
Choose 1756-TBNH or 1756-TBSH for the 20-pin field connection and key the RTB mechanically.
04 - Wire the two groups
Keep group 0 and group 1 line and load wiring aligned with the official L1, L2 and output-terminal diagram.
05 - Coordinate fusing and enclosure
Evaluate the group fuse, surge current and branch protection, then install the open-style module in a suitable industrial enclosure.

Environment

Operating temperature
0 to 60 degrees C.
Storage temperature
-40 to +85 degrees C.
Relative humidity
5 to 95 percent, noncondensing.
Mechanical endurance
2 g vibration at 10-500 Hz, 30 g operating shock and 50 g nonoperating shock.
Protection
Open-style equipment; install the module in a suitable industrial enclosure.
Certifications
cULus, CE, RCM, KC, ATEX, IECEx, UKEx, FM, UKCA, Morocco and CCC when marked.

FAQ

Q1. How can the exact quoted 1756-OA16 be verified?
Match 1756-OA16 on the quotation, module label and packaging. Confirm 16 outputs, two mechanically fused eight-point groups, the 74-265 VAC range and the 20-pin RTB interface.
Q2. How can New, Used or Refurbished condition be distinguished?
Request date-marked photos of the full label, serial and series markings, 16 output indicators, both fuse indicators, RTB connector, backplane connector and housing. Check for fuse replacement marks, discolored terminals, altered labels or repaired plastic.
Q3. How should supplier legality and reliability be checked?
Verify the supplier legal entity, registered address, invoice details, payment beneficiary and traceable contact. The offer must identify Allen-Bradley, 1756-OA16, condition, quantity and whether the 20-pin RTB and fuses are included.
Q4. Which specifications must engineering confirm before purchase?
Confirm 74-265 VAC at 47-63 Hz, 0.5 A per point, 2 A per group, 4 A per module, 10 mA minimum load, surge-current limits, two-group wiring, 1756-TBNH or 1756-TBSH RTB and chassis backplane capacity.
Q5. What physical evidence should be requested before payment?
Ask for date-marked photos showing the full 1756-OA16 label, serial and series markings, output and fuse indicators, 20-pin RTB connector, backplane edge connector, housing condition, fuse areas and packaging.
Q6. Can 1756-OA16I, 1756-OA8 or 1756-OA16K replace 1756-OA16?
Not automatically. The isolated, eight-point and conformal-coated variants differ in channel arrangement, RTB, load capacity, wiring and environmental construction. Confirm the exact electrical and installation requirements before substitution.

Recommend Models

85-15-2135
2910-3014-00
AT30
L105.0005.2.4
VL-690393-1 N16645
GEH-3323
YG-1 SV820059
SMC-35
ABB AF09-30-10-13
00332894-03
BOSS50 PL-5 B01-NN
8501X040
DIO 1000
C131207
TPPLAWA2SNNNN
100-C23D*10
PMIN-32FR-0.3M
48ASE1M20
1781-A4T
ABB PR010/T
S811+T24N3S
823278-C6
TM190-YDM05
MC-i4 1006146-08
S08-3FVG-050
364215000
GE 6128785
PS2E
KJ4001X1-CA1
D7M-KM22
48DA17A
1771-OB
2002-1611/1000-541
HMCP003A0C
516-371-E4-X-PU
42FB-F2LNA-A2
NVFS3210-5DZ 24vdc VFS3000
500L-DOD930
9905-863
NU305EC
7VK6111-5AB92-4YN0/EE
ZL-TSD8-24
PK-72
1771-IA2
2000-5420/1399-987
ABB REC670 1MRK004814-AC
WMZS2D32
NVFS3300-5FZ
4.4T-2.9-RSS
MCV116A1501
123T
E296T12IS120/N
1746-IV16
082SA415E
VX2330-03-5DZ1
NORD FLEXBLOC 60493000
USM35X
PUW-20
LC1D09
MPCKT55NAX20N

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000