BENTLY NEVADA | 3300 XL 8 MM PROXIMITY TRANSDUCER SYSTEM
330180-X1-05 MOD:145004-75
Modification-Controlled Proximitor Sensor
|
|
Base 330180 | X1 custom configuration | approval option 05 | MOD 145004-75 | standard 8 mm system reference values shown separately
LEAD TIME: In stock | WARRANTY: 1 year |
BENTLY NEVADA 330180-X1-05 MOD:145004-75
MODIFICATION-CONTROLLED 3300 XL 8 MM PROXIMITOR SENSOR
|
330180-X1-05 MOD:145004-75 is based on the 3300 XL 8 mm Proximitor Sensor. Official public documents identify base 330180 and option 05 approvals; X1 and MOD 145004-75 are not publicly decoded, so exact modified dimensions, weight and configuration-specific deviations are not inferred. |
|
Technical Data
330180-X1-05 MOD:145004-75 verified public-document scope
|
|
Complete model
|
330180-X1-05 MOD:145004-75
|
|
Product family
|
3300 XL 8 mm Proximity Transducer System
|
|
Product type
|
Modification-controlled Proximitor Sensor
|
|
Dimensions
|
Not published for 330180-X1-05 MOD:145004-75
|
|
Weight
|
Not published for 330180-X1-05 MOD:145004-75
|
|
Base part number
|
330180
|
|
Configuration field
|
X1 - not decoded in public official documentation
|
|
Modification ID
|
145004-75 - modification details not publicly released
|
|
Standard linear range reference
|
2.0 mm (80 mils) for a standard 3300 XL 8 mm system
|
|
Standard scale factor reference
|
7.87 V/mm (200 mV/mil)
|
|
Standard frequency response reference
|
0 to 10 kHz, +0/-3 dB typical
|
|
Supply voltage reference
|
-17.5 to -26 Vdc without barriers
|
|
Current consumption reference
|
12 mA maximum
|
|
Output resistance reference
|
50 ohm
|
|
Standard sensor material reference
|
A308 aluminum
|
|
Operating temperature reference
|
-52 to 100 deg C (-62 to 212 deg F)
|
|
Storage temperature reference
|
-52 to 105 deg C (-62 to 221 deg F)
|
|
Standard sensor style
|
DIN-rail or panel-mount Proximitor Sensor family
|
|
System compatibility
|
3300 XL 8 mm probes and extension cables subject to modified configuration review
|
|
Approval option
|
05
|
|
Approval scope
|
CSA, ATEX and IECEx are listed for standard option 05
|
|
Modification control
|
X1 and MOD 145004-75 may change standard construction or performance
|
|
Public configuration status
|
Exact X1 and MOD content is not published
|
|
Commissioning check
|
Verify the supplied modified documentation before installation
|
|
CONTACT
STELLA
|
|
Applications & Features
Standard-system functions with modification control
|
|
Non-contact measurement
The base 3300 XL 8 mm system supports shaft vibration and position measurements.
|
Signal conditioning
The Proximitor Sensor converts the probe signal into a calibrated voltage output.
|
|
System matching
Probe, extension cable and sensor must form a compatible total-length system.
|
Modified build
X1 and MOD 145004-75 require configuration-specific documentation before applying standard assumptions.
|
|
Electrical Interface
Standard 3300 XL 8 mm reference characteristics
|
|
Power
Standard reference is -17.5 to -26 Vdc at 12 mA maximum.
|
Output
Standard reference output resistance is 50 ohm.
|
|
Scale and range
Standard system reference is 7.87 V/mm across a 2.0 mm linear range.
|
Bandwidth
Standard system reference response is 0 to 10 kHz at +0/-3 dB typical.
|
|
Installation
Controls for a modification-specific sensor
|
|
Document review
Obtain the supplied MOD 145004-75 drawing or data sheet before wiring.
|
System length
Match the probe and extension cable to the exact modified sensor configuration.
|
|
Mounting
Confirm DIN-rail or panel mounting only from the supplied configuration record.
|
Commissioning
Verify supply voltage, gap voltage, scale factor and alarm-system response after installation.
|
|
Compliance
Published approval evidence and modification limits
|
|
Base family
|
3300 XL 8 mm Proximity Transducer System
|
|
Base sensor
|
330180 Proximitor Sensor
|
|
Approval option
|
05
|
|
Published standard approvals
|
CSA, ATEX and IECEx
|
|
Operating temperature reference
|
-52 to 100 deg C (-62 to 212 deg F)
|
|
Storage temperature reference
|
-52 to 105 deg C (-62 to 221 deg F)
|
|
Modification disclosure
|
X1 and MOD 145004-75 are not decoded in public documents
|
|
Final compliance check
|
Use the modified unit label and supplied documentation for site acceptance
|
|
FAQ
Six checks specific to 330180-X1-05 MOD:145004-75
|
|
1. How can the quoted complete model be verified?
Require the quotation, nameplate and packing list to show 330180-X1-05 and MOD:145004-75 together. Confirm approval option 05 as a separate field.
|
|
2. How can New, Used or Refurbished condition be distinguished?
Inspect the enclosure, terminal area, mounting hardware, label and seals for tool marks, oxidation, replaced labels, disturbed coating or repair residue.
|
|
3. How can supplier legitimacy and reliability be checked?
Verify the legal entity, physical address, matching bank beneficiary and traceable quotation. The supplier should provide MOD-specific evidence rather than presenting standard 330180 data as exact.
|
|
4. What must engineers verify before purchase?
Check modified dimensions, weight, mounting, wiring, compatible probe and cable length, supply, output scaling, temperature limits and approval markings against the supplied MOD record.
|
|
5. What physical evidence should be requested before payment?
Request dated photos of the full label, MOD marking, terminals, enclosure and mounting interface, plus the modification drawing or data sheet tied to 145004-75.
|
|
6. Can a standard 330180 or another X suffix replace it?
No automatic substitution is valid. X1 and MOD 145004-75 may alter construction or performance, so replacement requires matching modified documentation and engineering approval.
|
|
Recommend Models
Random cross-brand reference list
|
||
|
MFH-5/3G-D-3-C
|
STREL-B 6501074
|
SDV531-S33/PRP
|
|
4000094-310
|
3HE00867CAAA01 SFP-GIGE EX-LC ROHS6/6 DDM-40/85C IPUIBD9DAA
|
EDS165
|
|
HC30WB5R1
|
131131-PR
|
100-260-XX
|
|
190613
|
ABB S800 I/O TU830V1 3BSE013234R1
|
BC-GT30 0103-003-00
|
|
MU325A
|
DTT31-A1C111DEX1BB
|
MPC-302-W
|
|
MART1T 3-2485
|
LDR 4811543
|
ABB RXSF1-220-250V RK 271 016-AS
|
|
ABB ATS010
|
M5004F1100
|
UC400, X13651492-02
|
|
MTN646991 REG-K 0-10V
|
ADV151-P00
|
PGDT04000F020
|
|
AMM-2F
|
XRE2024D
|
25-410-15-psi-SPMC
|
|
DM01D01ACC
|
0J-0P4595AB
|
DM-SCALER-C
|
|
DDNG485
|
K1225 K1225/1
|
ABB 1SAP450000R0001 AO523
|
|
51202329-402
|
LG-003551
|
QAM9120.040
|
|
DDRC810
|
9319400100 Be3-27/59-1a1n3
|
S927-P20000-020C ITM PI-700
|
|
KNA3 XS 85100036
|
ADPC-101
|
M24511
|
|
6ES71934CB300AA0
|
IO44E01KNX
|
51308307-175 / REV H / CC-TCNT01
|
|
06010 0-00
|
1756-IB16D
|
PCS090 PG090.204.A
|
|
SUPC4 R1D 37900218
|
MS-8A/VC
|
D05F-1/2A
|
|
AT-HDVS-RX
|
855W-G20Y3Y4
|
ZZ-135-U20
|
|
69-2160-04A0 700-26425-05
|
868 Fu5210
|
6504877
|
|
GT-MCX
|
1404-M505A-DNT
|
IQ3XCITE/128/BAC/100-240 IQ3-4002U7128
|