siemens 6es7157 0ac83 0xa0 simatic dp pa coupler fdc 157 0-0

SIMATIC S7 Series

Home >  Products >  SIEMENS >  SIMATIC S7 Series

Siemens 6ES7157-0AC83-0XA0 SIMATIC DP/PA Coupler FDC 157-0

Product Name: SIMATIC DP/PA Coupler FDC 157-0
Brand Name: Siemens
Model Number: 6ES7157-0AC83-0XA0
Place of Origin: Germany
Warranty: 12 Months
Whatsapp: +86 18020776782
Appurtenance:
  • Overview
  • Description
  • Redundant PA Design
  • Specifications
  • Installation & Service
  • Commercial Term
  • Contact info
  • FAQ
  • Other Products
  • Recommended Products
Redundancy-capable PROFIBUS DP-to-PA fieldbus coupler with integrated segment power and diagnostics
The FDC 157-0 converts the RS485 PROFIBUS DP physical layer at 45.45 kbit/s to PROFIBUS PA at 31.25 kbit/s. It electrically isolates the networks, supplies the PA segment, supports a 1 A PA load and can provide local diagnostics, ring redundancy or coupler redundancy.
Fieldbus topology check: Confirm stand-alone or DP/PA Link use, diagnostic address, PA segment current, termination, non-redundant or redundant bus module, ACT LED state and 24 V supply arrangement before replacing or expanding the installation.

Description

6ES7157-0AC83-0XA0 is the Siemens FDC 157-0 for linking PROFIBUS DP and PROFIBUS PA. With address 0, the coupler operates transparently and can replace 6ES7157-0AC82-0XA0 without configuration; diagnostics require the same nonzero address in the hardware configuration and at the DIL switches.
A redundant pair must use the BM FDC/FDC bus module and the correct RING setting. Before disturbing a live redundant segment, verify that the ACT LED on the coupler being removed is off, isolate its 24 V DC supply and preserve the PA termination and cable routing.

Redundant PA Design

The redundancy mode, bus module and segment termination must agree; a working pair can still be misconfigured at the DIL switches.
Ring redundancy
Use the BM FDC/FDC bus module with two FDC 157-0 couplers, set RING ON and document the active field-distributor ring.
Coupler redundancy
Use the same redundant bus module with RING OFF and preserve the AFS or center-feed topology and PA termination.
Live replacement
Remove only the inactive coupler, confirm ACT is off, disconnect its 24 V supply and then exchange the module.

Specifications

Product type designation SIMATIC DP/PA Coupler FDC 157-0
Order number 6ES7157-0AC83-0XA0
PROFIBUS DP rate 45.45 kbit/s
PROFIBUS PA rate 31.25 kbit/s
PA output 31 V DC +/-1 V; maximum 1 A segment current
DP address 1 to 125 by DIL switch; 0 disables diagnostics
Supply voltage 24 V DC, 20.4 to 28.8 V
Power consumption Maximum 2.3 A at 24 V DC
Power loss Maximum 13.4 W
Diagnostics SF, BF, DP, PA, ACT and ON LEDs; DP diagnostic records
Dimensions / weight 80 x 125 x 130 mm; approximately 515 g
PA device capacity Up to 31 PA field devices within the 1 A current limit

Installation & Service

  • Commission power, address, PA wiring and diagnostics in a controlled sequence so a segment fault is not mistaken for a defective coupler.
    Power and grounding
    Use a safely isolated SELV supply; in an ungrounded system use separate isolated 24 V supplies when electrical isolation must be retained.
    Address and mode
    Match the PROFIBUS address in the project and DIL switches, then select the required redundancy mode before applying power.
    Segment evidence
    Record PA current, terminator position, field-device count, BF or SF indications and the local LifeList before changing wiring.

Commercial Term

  • Quotation
    Current price and availability
    Payment
    T/T or agreed terms
    Lead time
    Confirmed with quotation
    Shipping
    DHL, FedEx, UPS or agreed freight
    Warranty
    12 months

Contact info

FAQ

Q1
How can I confirm that 6ES7157-0AC83-0XA0 will replace the installed DP/PA coupler correctly?
Check the complete order number, bus module, stand-alone or DP/PA Link arrangement, PROFIBUS address, PA termination and redundancy mode. It can replace 6ES7157-0AC82-0XA0 transparently at address 0, but diagnostic or redundant operation requires project and switch settings.
Q2
What should I check before removing 6ES7157-0AC83-0XA0 from a redundant PA segment?
Verify that the ACT LED on the coupler to be removed is not illuminated, confirm the partner coupler is healthy and disconnect the selected coupler from its 24 V DC supply. Label PA, DP and bus-module positions before moving any connection.
Q3
Why can 6ES7157-0AC83-0XA0 show a PROFIBUS DP fault after installation?
Compare the configured address with the DIL-switch address and confirm the DP master uses 45.45 kbit/s. Then check the DP connector, cable termination, selected redundancy mode and whether diagnostics were intentionally enabled with an address above 0.
Q4
Why can the PA LED or SF LED indicate a fault on 6ES7157-0AC83-0XA0?
Measure the PA segment load and voltage, confirm the total field-device current stays within 1 A, inspect for a short circuit or wire break and verify both end terminators. Read the local LifeList and diagnostic record before disconnecting devices.
Q5
How should I power 6ES7157-0AC83-0XA0 in an ungrounded installation?
Use an approved SELV 24 V DC supply and review the plant grounding concept. If an IM 153-2 and the coupler share one supply, electrical isolation can be cancelled; use two electrically isolated supplies where the isolation must be preserved.
Q6
What must be preserved when commissioning a replacement 6ES7157-0AC83-0XA0?
Record the former address, RING setting, bus-module type, ACT state, PA terminator position, segment current, connected field devices and diagnostic messages. Restore these items first, then verify DP communication, PA voltage and redundancy behavior.

Other Products

TMPU-750 17-505750-001
15993030
212.11UOS
2CDG110079R0011
PXC50-ED S55372-C110
MQSE-4S1-D
RO8-1.4 C29F
902 J/K PT100 ICP11J0450000
EVD0000T41
BLU300M-001
LEGRAND 002640
COBALT 6590
STBPDT3100
517-0147-04C 04-21-956029
VM-114H 2XINPUT
El-805u-d-868-500m
7000-5234-1, 4000-4175-2
9377-FB
RLED-CR
Wrt-822B
805U-D El-805u-d-868-500m
AUD50A100D 1636F
4TKNX IP20
TVAC10100
9377FB
JMG 4TKNX IP20
MP204
V130-J-R34
PT100 ICP11J0450000
1GK-00006



Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Mobile
Company Name
Message
0/1000