Sales
Jim Pei
|
Email
[email protected]
|
Phone/Whatsapp
+86 18020776782
|
|
Model Number
|
750-P5-G5-S5-HI-A20-R-E
|
|
Phase current input rating
|
5 A
|
|
Zero-sequence current input rating
|
5 A
|
|
Sensitive ground current input rating
|
5 A
|
|
DC control power
|
88-300 V DC
|
|
AC control power
|
70-265 V AC
|
|
AC control power frequency
|
48-62 Hz
|
|
Nominal control power burden
|
25 VA
|
|
Maximum control power burden
|
35 VA
|
|
Control power hold-up
|
30 ms
|
|
Analog output channels
|
8
|
|
Analog output range
|
4-20 mA
|
|
Maximum analog output load
|
600 ohm
|
|
Analog output accuracy
|
+/-1% of full scale
|
|
Analog output response
|
Less than 3 power cycles
|
|
Analog output isolation
|
Isolated outputs
|
|
Serial baud rate
|
300-19200 baud
|
|
Serial protocols
|
Modbus RTU; DNP 3.0
|
|
Serial parity
|
Programmable
|
|
Output relay count
|
8
|
|
Trip relay contact form
|
Form A
|
|
Close relay contact form
|
Form A
|
|
Auxiliary relays 3-7 contact form
|
Form C
|
|
Self-test relay 8 contact form
|
Form C
|
|
Relay contact material
|
Silver alloy
|
|
Solid-state trip rating
|
15 A at 250 V DC for 500 ms
|
|
Dielectric withstand
|
2 kV AC for 1 minute
|
|
Operating temperature
|
-40 to +60 C
|
|
Storage and shipping temperature
|
-40 to +85 C
|
|
Maximum relative humidity
|
95%, noncondensing at 55 C
|
|
Pollution degree
|
2
|
|
Front enclosure protection
|
IP40
|
|
Rear enclosure protection
|
IP20
|
|
Breaker-closed indicator
|
Red LED
|
|
Display configuration
|
Enhanced display
|
|
Minimum Order Quantity
|
1 Piece
|
|
Price
|
Contact for Jim
|
|
Packaging Details
|
Original new Factory Sealed
|
|
Delivery Time
|
3–7 Days
|
|
Payment Terms
|
T/T
|
|
Shipping Method
|
DHL / FedEx / UPS / TNT
|
|
Supply Ability
|
In stock
|
GE Multilin 750-P5-G5-S5-HI-A20-R-E is a feeder management relay with an enhanced display. Its ordering code selects phase, zero-sequence and sensitive ground current inputs. The HI power option accepts AC or DC control power. This A20 configuration provides eight 4-20 mA analog outputs. The red indicator identifies the breaker-closed state.
This protection relay belongs to the Multilin feeder management platform. The front display helps operators review feeder conditions and relay information. Output relays connect protection decisions to the associated switchgear. Confirm the full ordering code, installed settings and wiring before changing a unit. The display option must be distinguished from the separate Ethernet option.
750-P5-G5-S5-HI-A20-R-E supports feeder protection and management in industrial electrical distribution. It can be integrated into switchgear where operators need local indication, metering and protection functions. Coordinate the relay settings with the feeder protection study.
For control-room monitoring projects, 750-P5-G5-S5-HI-A20-R-E can transmit selected quantities through its configured analog outputs. Check the receiving equipment and output scaling as part of commissioning. The installed switchgear wiring and protection logic determine the final application.
|
MA1479A
|
46B/44-S12
|
M2150-2DBC 7000-5376-1
|
|
LNL-C65-MW-K
|
67CFR-600/VS 250PSI/0-60PSI
|
181B0747
|
|
FG-20i 1631005-003
|
2708371 PSI-MOS-RS232/FO
|
PCO2DA0BM0
|
|
LPS43
|
HMC-G03-V12
|
LA-21-L1L2-N
|
|
HWS600-24
|
BSM400GA120DN2FS-E3256
|
F430R3V10
|
|
C3COM-3
|
RS20-0800T1T1SDAPHH05.0.02
|
GDP-CBL-OBD/ETH-02
|
|
SMC5500/S SMC5500050407
|
DE4161-001
|
DPG500
|
|
67CFR-239 250PSI/0-125PSI
|
BN5930.48
|
ir425-D4-2
|
|
E70-24MCW-FW
|
TF223AD/U
|
Din-8SW8-I
|
|
K1241
|
2CDG110091R0011
|
2865120_ PI-EX-DO/REL-S
|
|
102044-00-48-15-02 DR TSE 060-987-166
|
DVI-M PN:26-584-01
|
EGX100MG
|
|
1Saj530000R0100
|
E0002181
|
C2N-MNETGW
|
|
SHO100-T
|
SQ121B6220 120BA220
|
RH328A
|