Parameter |
Specification |
|
Part Number |
8601-FT-NI |
|
Product Type |
Non-Incendive Field Terminal Module |
|
Manufacturer |
Emerson (GE Fanuc) |
|
System Compatibility |
PAC8000 Remote I/O System |
|
Hazardous Area Approval |
Class 1, Div 2, Groups A-D, T4 / Zone 2, IIC, T4 |
|
Field Wiring Location |
Zone 2 / Div 2 hazardous location |
|
Mounting |
|
|
Connection Method |
|
|
Conductor Size |
0.14 – 2.5 mm² |
|
Rated Voltage |
250V AC |
|
Maximum Current per Channel |
3A |
|
IP Rating |
|
|
Operating Temperature |
-40°C to +70°C |
|
Storage Temperature |
-40°C to +85°C |
|
Relative Humidity |
5% to 95% RH (non-condensing) |
|
Dimensions (W × D × H) |
8.8x4.1x4.2cm |
|
Weight |
0.08kg |
The 8601-FT-NI is a non-incendive Field Terminal module engineered for Emerson's PAC8000 Remote I/O system, serving as the primary wiring interface between field devices and control electronics. This 8601-FT-NI module snaps directly onto the PAC8000 carrier, accepting field wiring without the need for additional terminals or connections. The "NI" suffix denotes its non-incendive design, making the 8601-FT-NI suitable for Class 1 Div 2 and Zone 2 hazardous locations. With its blue molding for intrinsic safety field wiring identification, screw‑clamp termination, and comprehensive mechanical keying system, the 8601-FT-NI ensures reliable, safe, and serviceable field terminations in demanding industrial automation environments.
Hazardous Area Ready – Non-incendive (NI) design enables direct deployment in Class 1 Div 2 / Zone 2 locations without expensive explosion‑proof enclosures
Tool‑Free Module Replacement – Snap‑on carrier mounting allows field terminals to be changed easily if damaged, minimizing downtime
Integrated Safety Keying – Comprehensive mechanical keying system prevents incorrect module installation, ensuring equipment safety
Service‑Friendly Design – Clear terminal labeling and front‑accessible wiring enable technicians to troubleshoot without disconnecting entire modules
Modular PAC8000 Ecosystem – Seamless integration with PAC8000's open architecture, supporting communication via various Bus Interface Modules (BIMs) or Controllers
Non-Incendive (NI) Safety Classification – Engineered to prevent ignition in hazardous atmospheres by limiting energy at field terminals
Screw‑Clamp Termination – Accepts 0.14 – 2.5 mm² conductors with secure, reliable field wiring connections
Snap‑On Carrier Mounting – One field terminal per I/O module snaps onto the PAC8000 carrier without tools
Mechanical Keying System – Comprehensive keying prevents incorrect module installation
Compact Form Factor – 42 × 88 × 39.5 mm dimensions with 78 g weight for space‑efficient cabinet layouts
Wide Environmental Tolerance – -40°C to +70°C operating range with 5‑95% RH non‑condensing humidity tolerance
Blue Molding Identification – Clear visual differentiation for intrinsic safety field wiring applications
The 8601-FT-NI Field Terminal serves as the physical interface between field devices and the PAC8000 I/O system. It mounts onto a PAC8000 carrier, which forms the system's physical and electrical backbone by providing DIN rail mounting and interconnecting the Bus Interface Module (BIM) or Controller, power supplies, I/O modules, and field terminals.
The "Non-Incendive" (NI) designation indicates that the 8601-FT-NI is designed to prevent ignition in hazardous atmospheres by limiting the energy available at the field terminals to a level below that required to ignite a specific gas or dust mixture. This allows deployment in Zone 2 / Div 2 locations without bulky explosion‑proof enclosures. The module provides electrical isolation between groups of inputs, preventing ground loops and cross‑talk between signals from different parts of the plant. Integrated RC filters and surge suppressors clamp voltage spikes, protecting the sensitive electronics of the main controller from damage.
Field wiring is terminated via screw‑clamp terminals (0.14 – 2.5 mm² conductors), with each channel rated for 3A at 250V AC. The clear terminal labeling and "front‑accessible" design allow technicians to wire and troubleshoot without disconnecting the entire module.
|
Item |
Description |
Part Number / Reference |
|
Non-Incendive Field Terminal |
Standard field terminal for Zone 2 / Div 2 hazardous locations |
8601-FT-NI |
|
Standard Field Terminal |
General purpose field terminal (non-hazardous) |
8602-FT-ST |
|
Non-Incendive Fused Field Terminal |
Non-incendive terminal with 2A fuse protection |
8603-FT-FU |
|
THC Field Terminal |
Field terminal for thermocouple inputs |
8605-FT-TC |
|
RTD Field Terminal |
Field terminal for RTD inputs |
8606-FT-RT |
|
4-Wire Transmitter Field Terminal |
Field terminal for 4-wire transmitters |
8615-FT-4W |
|
16/30-Channel DI Field Terminal |
Field terminal for 16/30-channel digital inputs |
8617-FT-NI |
|
2A Fuse Pack |
Replacement fuses (10 per pack) |
8401-FU-2A |