One appliance links Ethernet-based Modbus TCP/IP with PROFIBUS DP field communication.
Product Name: Modbus TCP/IP to PROFIBUS DP Master Gateway
Brand Name: ProSoft Technology
Model Number: 4204-MNET-PDPM
Place of Origin: USA
Warranty: 12 Months
Whatsapp: +86 18020776782
Email: [email protected]
| Minimum Order Quantity | 1 Piece |
|---|---|
| Price | Contact for Jim |
| Packaging Details | Original new Factory Sealed |
| Delivery Time | 3-7 Days |
| Payment Terms | T/T |
| Shipping Method | DHL / FedEx / UPS / TNT |
| Supply Ability | Brand new, In Stock |
| Model Number | 4204-MNET-PDPM |
|---|---|
| Product Family | ProLinx Gateway |
| Product Type | Industrial communication gateway |
| Protocol Role | Modbus TCP/IP to PROFIBUS DP Master |
| Hardware Series | C |
| Nameplate Version | 2.44 |
| Nameplate Operating System | 2.41 |
| Default Nameplate IP Address | 192.168.0.100 |
| Serial Port Modes | RS-232; RS-422; RS-485 |
| Input Voltage Range | 18 to 32 V DC |
| Maximum Input Load | 500 mA |
| Ambient Temperature | -20 to +50 C |
| Hazardous Location Marking | Class I, Division 2, Groups A, B, C, D |
| Temperature Code | T4 |
| ATEX Marking | Ex nA IIC T4 |
| ATEX Reference | 03 ATEX 0312273U |
| Compliance Marks | cULus; CE |
| Country Marking | Made in USA |
4204-MNET-PDPM is a ProSoft Technology ProLinx communication gateway identified by the supplied Series C nameplate. The MNET-PDPM gateway function connects Modbus TCP/IP communication with a PROFIBUS DP Master network role. The photographed unit is marked for 18 to 32 V DC input, 500 mA maximum load and -20 to +50 C ambient operation. Port 0 supports selectable RS-232, RS-422 or RS-485 operation, while the nameplate records version 2.44, operating system 2.41 and IP address 192.168.0.100. Hazardous-location, cULus, CE and ATEX markings are also present on the exact unit.
4204-MNET-PDPM provides a protocol boundary where Ethernet controllers or supervisory systems must exchange data with PROFIBUS DP field devices. The ProLinx architecture uses a configured internal data map so each network can read or write the required process values. It is suited to modernization projects that retain PROFIBUS drives, remote I/O or instruments while adding Modbus TCP/IP connectivity. Existing configuration files, IP settings, fieldbus parameters and node assignments should be backed up before replacement. Hardware series and firmware information must remain part of the compatibility review.
One appliance links Ethernet-based Modbus TCP/IP with PROFIBUS DP field communication.
Internal registers coordinate the values exchanged by both protocol drivers.
Series C, firmware and operating-system information are preserved from the supplied nameplate.
Verify the configured address rather than assuming the nameplate default is still active.
Retain slave addresses, baud-rate settings and device configuration records.
Match Port 0 selection to the connected RS-232, RS-422 or RS-485 service interface.
Keep the supply and classified-location conditions within the exact unit markings.
It links Modbus TCP/IP communication to a PROFIBUS DP Master network role.
The nameplate identifies Series C, version 2.44 and operating system 2.41.
The photographed unit states an 18 to 32 V DC input range with 500 mA maximum load.
The visible 192.168.0.100 value may have been changed in the installed project, so the active configuration must be backed up.
The complete model, Series C label and revision details are checked against the order.
Preparation starts after payment and stock confirmation, with timing stated in the quotation.